HP Ultrium tape drive 960i, Ultrium tape drive Ultrium 230i manual Plastic rail Server latch

Page 24

plastic rail

server latch

Figure 8a: securing drive to mounting hardware

(example shows HP ProLiant ML530)

use M3 screws

Figure 8b: securing drive, no mounting hardware

(example shows HP AlphaServer ES40)

20

Image 24
Contents Hp StorageWorks Ultrium tape drive Ultrium 230i, 460iOpen this flap for quick start installation poster Page Page Internal drives contents Product Details Before you start How can I check the Scsi bus?Do I need additional items for installation? What are the mounting requirements for the tape drive?Mounting bay Mounting hardwareBackup software and drivers Backup softwareDrivers Windows users Unix and OpenVMS usersHP StorageWorks Tape CD-ROM Using the CD-ROM Scsi HBA Check the Scsi connection Supported Scsi bus typesChecking the Scsi ID Check the drive’s Scsi ID Preparing mounting bay in a typical HP AlphaServer Prepare the mounting bay M3 offset mounting screws ML370 Attach mounting hardware HP ProLiant serversOther servers Mounting railsInstalling the drive Install the drive Attaching power and Scsi cables Attach power and Scsi cables Where should the Scsi terminator be?Plastic rail Server latch No mounting hardware used HP AlphaServer Secure the driveMounting hardware used HP ProLiant Loading a cartridge Eject button Verify installation Check operationTo load a cartridge To unload a cartridgeUltrium 230 tape drive controls and indicators Accessibility features Drive Error second, amberYour HP StorageWorks Ultrium tape drive Front panel LEDsWrite-protecting cartridges Use the correct media Data cartridgesWorm data cartridges Cleaning cartridges To clean the tape driveWrite-protecting cartridges Caring for cartridgesRegister your tape drive Using HP OBDR, step Using HP Obdr Remote disaster recovery ProLiant servers onlyIt returns to normal tape drive mode and restores the data CompatibilityTesting for compatibility If restore failsRunning HP Obdr Keyboard shortcut for HP ProLiant serversDiagnostic tools Checking drive installation with Library & Tape ToolsTroubleshooting with Library & Tape Tools HP Library & Tape ToolsPerformance Assessment Tools Optimizing performance Is the tape drive on a dedicated Scsi bus?Can your system deliver the required performance? Page Troubleshooting Web troubleshooting guideProblems encountered during installation If your server is in its original configuration no Adapter installedOn Unix systems, see the Unix Configuration Backup software that states support forTesting after installation Please see Problems with cartridges on Use HP Library & Tape Tools to check thatAssistance Understanding the LEDs LEDs during self-testUsing the LEDs for troubleshooting Or known data cartridge after cleaning, call for ServiceNone. The cleaning cartridge will eject on Cleaning cycle can take up to 5 minutes toCondition persists, call for service There is a firmware Download problemPower cycle or reset the drive Upgrade the firmware. If the condition persists, callProblems with cartridges Looking after cartridgesOperating and storage environment Cartridge is jammedDrive will not accept cartridge or ejects it immediately Press and hold the Eject button for 10 secondsHow to contact HP Other sources of informationReplacing your tape drive To disconnect your driveTo reconnect your tape drive Page Page Q1538-90905