York DJ150 installation manual Turns Open ESP‡ CFM BHP

Page 29
Blower performance for gas heat includes maximum number of heat tubes available for each tonnage.
Blower performance for gas heat includes maximum number of heat tubes available for each tonnage.

035-19046-002-B-0104

TABLE 15: DJ150, 12-1/2 TON STANDARD MOTOR DOWN SHOT BLOWER PERFORMANCE* †

 

 

 

 

 

 

 

 

 

TURNS OPEN**

 

 

 

 

 

 

 

 

ESP

 

0

 

 

1

 

 

2

 

 

 

 

3

 

 

4

 

 

5

 

 

CFM

W††

BHP

CFM

W††

BHP

CFM

W††

 

BHP

CFM

 

W††

BHP

CFM

W††

BHP

CFM

W††

BHP

0.4

5078

3630

3.89

4809

3103

3.33

4594

3053

 

3.27

4360

 

2478

2.66

4090

2093

2.24

3812

1798

1.93

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.6

4865

3456

3.71

4584

2961

3.17

4349

2912

 

3.12

4106

 

2318

2.49

3814

1964

2.11

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.8

4642

3284

3.52

4356

2828

3.03

4089

2776

 

2.98

3840

 

2137

2.29

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.0

4408

3114

3.34

4124

2705

2.90

3815

2647

 

2.84

-

 

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.2

4164

2947

3.16

3889

2592

2.78

-

-

 

-

-

 

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.4

3910

2787

2.99

-

-

-

-

-

 

-

-

 

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*.

†.Blower performance includes two-inch throwaway filters.

‡.ESP (External Static Pressure) given is that available for the supply and return air duct system. All internal resistances have been deducted from the total static pressure of the blower.

**. “Turns Open” refers to the setting of the variable pitch motor sheave, where “0 Turns Open” is fully closed.

††.W = Watts

TABLE 16: DJ150, 12-1/2 TON OPTIONAL MOTOR DOWN SHOT BLOWER PERFORMANCE* †

 

 

 

 

 

 

 

 

 

TURNS OPEN**

 

 

 

 

 

 

 

 

ESP

 

0

 

 

1

 

 

2

 

 

 

 

3

 

 

4

 

 

5

 

 

CFM

W††

BHP

CFM

W††

BHP

CFM

W††

 

BHP

CFM

 

W††

BHP

CFM

W††

BHP

CFM

W††

BHP

0.4

5994

5400

5.79

5565

4369

4.69

5488

4169

 

4.47

5264

 

3599

3.86

4990

3085

3.31

4738

2812

3.02

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.6

5824

5216

5.59

5368

4186

4.49

5289

3991

 

4.28

5049

 

3437

3.69

4763

2937

3.15

4491

2655

2.85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.8

5641

5022

5.39

5170

4012

4.30

5076

3807

 

4.08

4822

 

3272

3.51

4528

2790

2.99

4235

2497

2.68

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.0

5444

4819

5.17

4971

3846

4.12

4847

3618

 

3.88

4584

 

3103

3.33

4286

2644

2.83

3969

2340

2.51

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.2

5233

4609

4.94

4771

3687

3.95

4604

3426

 

3.67

4335

 

2933

3.15

4035

2499

2.68

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.4

5009

4394

4.71

4571

3537

3.79

4346

3233

 

3.47

4074

 

2762

2.96

3777

2356

2.53

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.6

4771

4174

4.48

4370

3395

3.64

4074

3040

 

3.26

3802

 

2590

2.78

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.8

4520

3951

4.24

4169

3262

3.50

3786

2850

 

3.06

-

 

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.0

4255

3728

4.00

3966

3137

3.36

-

-

 

-

-

 

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.2

3976

3505

3.76

3763

3020

3.24

-

-

 

-

-

 

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*.

†.Blower performance includes two-inch throwaway filters.

‡.ESP (External Static Pressure) given is that available for the supply and return air duct system. All internal resistances have been deducted from the total static pressure of the blower.

**. “Turns Open” refers to the setting of the variable pitch motor sheave, where “0 Turns Open” is fully closed.

††.W = Watts

Unitary Products Group

29

Image 29
Contents Installation Manual Table of Contents List of Tables List of FiguresInspection Safety ConsiderationsGeneral Renewal Parts ReferenceApprovals Nomenclature 12½ Ton Predator Model Number Nomenclature 150 N15NOMENCLATURE, Additional Options Preceding Installation InstallationInstallation Safety Information Limitations Compressor SectionPREDATOR Magnum Component Location Unit Voltage Limitations Unit Temperature LimitationsRigging and Handling LocationClearances Unit WeightsPoint Load Weight Detail C Unit DimensionsBottom Duct Openings from Above Duct Covers Rear Duct Dimensions DuctworkPREDATOR Magnum Roof Curb Dimensions Control Wire Sizes Thermostat WiringPower and Control Wiring FiltersElectronic Thermostat Field Wiring Power Wiring DetailField Wiring 24 Volt Thermostat Contactor 1M Factory or Field Ground MCA Minimum Supply AIR CFM Physical DataOptional Electric Heat GAS Piping Optional GAS HeatGAS Heat Application Data LP UNITS, Tanks and Piping GAS ConnectionFactory Installed Options Field Installed Accessories Indoor AIR Quality AQ Minimum Position AdjustmentEnthalpy SET Point Adjustment Enthalpy SET Point Chart Blower Rotation PhasingSupply AIR Limitations Belt TensionTurns Open ESP‡ CFM BHP Blower performance includes dry coil and two-inch AIR Balance Indoor Blower SpecificationsChecking AIR Quantity Method ONEDRY Coil Delta P Supply AIR Drive Adjustment Additional Static Resistance OperationMotor Sheave Datum Diameters Cooling Sequence of OperationCooling Operation Errors Economizer Single or Dual with Power ExhaustHIGH-PRESSURE Limit Switch No Outdoor AIR OptionsCompressor Protection Safety ControlsElectric Heat Limit Setting Electric Heating Operation ErrorsElectric Heating Sequence of Operations Electric Heat Anticipator SetpointsIgnition Control Board GAS Heating Operation ErrorsGAS Heating Sequence of Operations GAS Heat Limit Control Settings START-UP GAS Heat START-UP CoolingManifold GAS Pressure Adjustment Post Start ChecklistShut Down Checking GAS InputGAS Rate Cubic Feet PER Hour BURNERS/ORIFICES INSPECTION/SERVICING Adjustment of Temperature RiseCharging the Unit TroubleshootingPREDATOR Magnum Flash Codes Unit Control Board Flash CodesBasic Troubleshooting Flowchart Trip Failure Flow Chart Cooling Troubleshooting Guide Unitary Products Group 035-19046-002-B-0104 GAS Heat Troubleshooting Guide Unitary Products Group 035-19046-002-B-0104 Unitary Products Group Unitary 5005 Norman Products York Group Drive 73069

DJ150 specifications

The York DJ150 is a standout model in the world of portable DJ equipment, designed to cater to both budding DJs and seasoned professionals. Its sleek and compact form factor makes it highly portable, allowing for easy transporting to gigs, parties, or personal events.

One of the main features of the DJ150 is its user-friendly interface, which includes a simplified control layout. This design boils down essential functions into accessible buttons and knobs, enabling DJs to focus on their mixes without distractions. The large jog wheels are not only responsive but also provide precision when scratching and cueing tracks, making it a joy to use for both live performances and practice sessions.

In terms of sound quality, the York DJ150 is equipped with high-performance audio circuitry. It ensures that sound clarity is maintained, with a dynamic range that captures the intricacies of music. The device supports multiple audio formats, offering versatility for DJs that work with various types of digital music files.

The DJ150 integrates advanced technologies that facilitate seamless mixing and creative expression. With features such as built-in sound effects, loops, and samples, DJs can add their personal touch to sets. Additionally, the model includes an intelligent beat matching function which automatically syncs the tempo of different tracks, allowing for smooth transitions and uninterrupted flow.

Connectivity is another strong point for the York DJ150. It offers multiple input and output options, including USB ports for quick connections to a laptop or external devices, line inputs for instruments or microphones, and headphones output for monitoring. This ensures that users can connect a wide range of equipment while maintaining a clean setup.

Durability plays a key role in the DJ150's design, as it is built to withstand the rigors of frequent use. Its robust construction and quality materials contribute to its longevity, appealing to those who value reliable gear.

In conclusion, the York DJ150 represents a versatile solution for DJs seeking a blend of portability, functionality, and sound quality. Its comprehensive features and professional-grade technologies position it as a strong contender in the DJ equipment market, making it suitable for performances of all levels. Whether you are a novice starting your DJ journey or a seasoned pro looking for an efficient tool, the DJ150 ticks all the boxes.