York DJ150 installation manual Reference, Approvals, Renewal Parts

Page 5

035-19046-002-B-0104

REFERENCE

Additional information is available in the following reference forms:

Technical Guide - DJ150, 036-21484-002

General Installation - DJ150, 035-19046-002

Pre-start & Post-start Check List - 035-18466-000

Economizer Accessory -

Downflow Factory Installed, 035-18286-000

Downflow Field Installed, 035-18285-000

Horizontal Field Installed, 035-18287-000

Motorized Outdoor Air Damper 035-18283-000

Manual Outdoor Air Damper (0-100%) 035-18282-000

Manual Outdoor Air Damper (0-35%) 035-18281-000

Gas Heat Propane Conversion Kit 035-17374-000

Gas Heat High Altitude Kit (Natural Gas) 035-17282-000

Gas Heat High Altitude Kit (Propane) 035-17281-000

–60°F Gas Heat Kit 035-18216-000

Electric Heater Accessory 035-17291-001

Unit Renewal Parts List 035-19085-000

All forms referenced in this instruction may be ordered from:

Standard Register

Toll Free Fax: (877) 379-7920

Toll Free Phone: (877) 318-9675

APPROVALS

Design certified by CSA as follows:

1.For use as a cooling only unit, cooling unit with supple- mental electric heat or a forced air furnace.

2.For outdoor installation only.

3.For installation on combustible material and may be installed directly on combustible flooring or, in the U.S., on wood flooring or Class A, Class B or Class C roof cov- ering materials.

4.For use with natural gas (convertible to LP with kit).

This product must be installed in strict compliance with the enclosed installation instructions and any applicable local, state, and national codes including, but not limited to, building, electrical, and mechanical codes.

Incorrect installation may create a condition where the operation of the product could cause personal injury or property damage.

RENEWAL PARTS

Refer to York’s USER’S MAINTENANCE and SERVICE INFORMATION MANUAL Part Number 035-19047-001.

The installer should pay particular attention to the words: NOTE, CAUTION, and WARNING. NOTES are intended to clarify or make the installation easier. CAUTIONS are given to prevent equipment damage. WARNINGS are given to alert installer that personal injury and/or equipment damage may result if installation procedure is not handled properly.

Unitary Products Group

5

Image 5
Contents Installation Manual Table of Contents List of Tables List of FiguresInspection Safety ConsiderationsGeneral Renewal Parts ReferenceApprovals Nomenclature 12½ Ton Predator Model Number Nomenclature 150 N15NOMENCLATURE, Additional Options Preceding Installation InstallationInstallation Safety Information Limitations Compressor SectionPREDATOR Magnum Component Location Unit Voltage Limitations Unit Temperature LimitationsRigging and Handling LocationClearances Unit WeightsPoint Load Weight Detail C Unit DimensionsBottom Duct Openings from Above Duct Covers Rear Duct Dimensions DuctworkPREDATOR Magnum Roof Curb Dimensions Control Wire Sizes Thermostat WiringPower and Control Wiring FiltersElectronic Thermostat Field Wiring Power Wiring DetailField Wiring 24 Volt Thermostat Contactor 1M Factory or Field Ground MCA Minimum Supply AIR CFM Physical DataOptional Electric Heat GAS Piping Optional GAS HeatGAS Heat Application Data LP UNITS, Tanks and Piping GAS ConnectionFactory Installed Options Field Installed Accessories Indoor AIR Quality AQ Minimum Position AdjustmentEnthalpy SET Point Adjustment Enthalpy SET Point Chart Blower Rotation PhasingSupply AIR Limitations Belt TensionTurns Open ESP‡ CFM BHP Blower performance includes dry coil and two-inch AIR Balance Indoor Blower SpecificationsChecking AIR Quantity Method ONEDRY Coil Delta P Supply AIR Drive Adjustment Additional Static Resistance OperationMotor Sheave Datum Diameters Cooling Sequence of OperationCooling Operation Errors Economizer Single or Dual with Power ExhaustHIGH-PRESSURE Limit Switch No Outdoor AIR OptionsCompressor Protection Safety ControlsElectric Heat Limit Setting Electric Heating Operation ErrorsElectric Heating Sequence of Operations Electric Heat Anticipator SetpointsIgnition Control Board GAS Heating Operation ErrorsGAS Heating Sequence of Operations GAS Heat Limit Control Settings START-UP GAS Heat START-UP CoolingManifold GAS Pressure Adjustment Post Start ChecklistShut Down Checking GAS InputGAS Rate Cubic Feet PER Hour BURNERS/ORIFICES INSPECTION/SERVICING Adjustment of Temperature RiseCharging the Unit TroubleshootingPREDATOR Magnum Flash Codes Unit Control Board Flash CodesBasic Troubleshooting Flowchart Trip Failure Flow Chart Cooling Troubleshooting Guide Unitary Products Group 035-19046-002-B-0104 GAS Heat Troubleshooting Guide Unitary Products Group 035-19046-002-B-0104 Unitary Products Group Unitary 5005 Norman Products York Group Drive 73069

DJ150 specifications

The York DJ150 is a standout model in the world of portable DJ equipment, designed to cater to both budding DJs and seasoned professionals. Its sleek and compact form factor makes it highly portable, allowing for easy transporting to gigs, parties, or personal events.

One of the main features of the DJ150 is its user-friendly interface, which includes a simplified control layout. This design boils down essential functions into accessible buttons and knobs, enabling DJs to focus on their mixes without distractions. The large jog wheels are not only responsive but also provide precision when scratching and cueing tracks, making it a joy to use for both live performances and practice sessions.

In terms of sound quality, the York DJ150 is equipped with high-performance audio circuitry. It ensures that sound clarity is maintained, with a dynamic range that captures the intricacies of music. The device supports multiple audio formats, offering versatility for DJs that work with various types of digital music files.

The DJ150 integrates advanced technologies that facilitate seamless mixing and creative expression. With features such as built-in sound effects, loops, and samples, DJs can add their personal touch to sets. Additionally, the model includes an intelligent beat matching function which automatically syncs the tempo of different tracks, allowing for smooth transitions and uninterrupted flow.

Connectivity is another strong point for the York DJ150. It offers multiple input and output options, including USB ports for quick connections to a laptop or external devices, line inputs for instruments or microphones, and headphones output for monitoring. This ensures that users can connect a wide range of equipment while maintaining a clean setup.

Durability plays a key role in the DJ150's design, as it is built to withstand the rigors of frequent use. Its robust construction and quality materials contribute to its longevity, appealing to those who value reliable gear.

In conclusion, the York DJ150 represents a versatile solution for DJs seeking a blend of portability, functionality, and sound quality. Its comprehensive features and professional-grade technologies position it as a strong contender in the DJ equipment market, making it suitable for performances of all levels. Whether you are a novice starting your DJ journey or a seasoned pro looking for an efficient tool, the DJ150 ticks all the boxes.