York DJ150 installation manual Installation Safety Information, Preceding Installation

Page 8

035-19046-002-B-0104

TC

Technicoat Condenser Coil & Coil Guard

 

 

TD

Technicoat Condenser Coil & Dirty Filter Switch

 

 

TG

Technicoat Condenser Coil, Coil Guard, & Dirty Filter Switch

 

 

TJ

Technicoat Evaporator Coil

 

 

TL

Technicoat Evaporator Coil & Coil Guard

 

 

TM

Technicoat Evaporator Coil & Dirty Filter Switch

 

 

TQ

Technicoat Evaporator Coil, Coil Guard, & Dirty Filter Switch

 

 

TS

Technicoat Evaporator & Condenser Coils

 

 

TU

Technicoat Evaporator & Condenser Coils & Coil Guard

 

 

TV

Technicoat Evaporator & Condenser Coils & Dirty Filter Switch

 

 

TY

Technicoat Evaporator & Condenser Coils, Coil Guard, & Dirty Filter Switch

 

 

INSTALLATION

INSTALLATION SAFETY INFORMATION

Read these instructions before continuing this appliance installation. This is an outdoor combination heating and cool- ing unit. The installer must assure that these instructions are made available to the consumer and with instructions to retain them for future reference.

1.Refer to the furnace rating plate for the approved type of gas for this furnace.

2.Install this furnace only in a location and position as specified on Page 11 of these instructions.

3.Never test for gas leaks with an open flame. Use com- mercially available soap solution made specifically for the detection of leaks when checking all connections, as specified on Pages 8, 24, 25 and 40 of these instruc- tions.

4.Always install furnace to operate within the furnace's intended temperature-rise range with the duct system and within the allowable external static pressure range, as specified on the unit name/rating plate, specified on Page 42 of these instructions.

5.This equipment is not to be used for temporary heating of buildings or structures under construction.

FIRE OR EXPLOSION HAZARD

Failure to follow the safety warning exactly could result in serious injury, death or property damage.

Never test for gas leaks with an open flame. use a commercially available soap solution made specifi- cally for the detection of leaks to check all connec- tions. A fire or explosion may result causing property damage, personal injury or loss of life.

PRECEDING INSTALLATION

1.Remove the two screws holding the brackets in the front, rear and compressor side fork-lift slots.

Bracket

Turn down

Screws

 

FIGURE 1 - UNIT SHIPPING BRACKET

8

Unitary Products Group

Image 8
Contents Installation Manual Table of Contents List of Figures List of TablesInspection Safety ConsiderationsGeneral Renewal Parts ReferenceApprovals 12½ Ton Predator Model Number Nomenclature 150 N15 NomenclatureNOMENCLATURE, Additional Options Preceding Installation InstallationInstallation Safety Information Compressor Section LimitationsPREDATOR Magnum Component Location Unit Temperature Limitations Unit Voltage LimitationsRigging and Handling LocationClearances Unit WeightsPoint Load Weight Unit Dimensions Detail CBottom Duct Openings from Above Rear Duct Dimensions Ductwork Duct CoversPREDATOR Magnum Roof Curb Dimensions Thermostat Wiring Control Wire SizesPower and Control Wiring FiltersPower Wiring Detail Electronic Thermostat Field WiringField Wiring 24 Volt Thermostat Contactor 1M Factory or Field Ground MCA Minimum Supply AIR CFM Physical DataOptional Electric Heat GAS Piping Optional GAS HeatGAS Heat Application Data GAS Connection LP UNITS, Tanks and PipingFactory Installed Options Field Installed Accessories Indoor AIR Quality AQ Minimum Position AdjustmentEnthalpy SET Point Adjustment Enthalpy SET Point Chart Phasing Blower RotationSupply AIR Limitations Belt TensionTurns Open ESP‡ CFM BHP Blower performance includes dry coil and two-inch Indoor Blower Specifications AIR BalanceChecking AIR Quantity Method ONEDRY Coil Delta P Supply AIR Drive Adjustment Operation Additional Static ResistanceMotor Sheave Datum Diameters Cooling Sequence of OperationEconomizer Single or Dual with Power Exhaust Cooling Operation ErrorsHIGH-PRESSURE Limit Switch No Outdoor AIR OptionsSafety Controls Compressor ProtectionElectric Heating Operation Errors Electric Heat Limit SettingElectric Heating Sequence of Operations Electric Heat Anticipator SetpointsIgnition Control Board GAS Heating Operation ErrorsGAS Heating Sequence of Operations GAS Heat Limit Control Settings START-UP Cooling START-UP GAS HeatPost Start Checklist Manifold GAS Pressure AdjustmentShut Down Checking GAS InputGAS Rate Cubic Feet PER Hour Adjustment of Temperature Rise BURNERS/ORIFICES INSPECTION/SERVICINGTroubleshooting Charging the UnitPREDATOR Magnum Flash Codes Unit Control Board Flash CodesBasic Troubleshooting Flowchart Trip Failure Flow Chart Cooling Troubleshooting Guide Unitary Products Group 035-19046-002-B-0104 GAS Heat Troubleshooting Guide Unitary Products Group 035-19046-002-B-0104 Unitary Products Group Unitary 5005 Norman Products York Group Drive 73069

DJ150 specifications

The York DJ150 is a standout model in the world of portable DJ equipment, designed to cater to both budding DJs and seasoned professionals. Its sleek and compact form factor makes it highly portable, allowing for easy transporting to gigs, parties, or personal events.

One of the main features of the DJ150 is its user-friendly interface, which includes a simplified control layout. This design boils down essential functions into accessible buttons and knobs, enabling DJs to focus on their mixes without distractions. The large jog wheels are not only responsive but also provide precision when scratching and cueing tracks, making it a joy to use for both live performances and practice sessions.

In terms of sound quality, the York DJ150 is equipped with high-performance audio circuitry. It ensures that sound clarity is maintained, with a dynamic range that captures the intricacies of music. The device supports multiple audio formats, offering versatility for DJs that work with various types of digital music files.

The DJ150 integrates advanced technologies that facilitate seamless mixing and creative expression. With features such as built-in sound effects, loops, and samples, DJs can add their personal touch to sets. Additionally, the model includes an intelligent beat matching function which automatically syncs the tempo of different tracks, allowing for smooth transitions and uninterrupted flow.

Connectivity is another strong point for the York DJ150. It offers multiple input and output options, including USB ports for quick connections to a laptop or external devices, line inputs for instruments or microphones, and headphones output for monitoring. This ensures that users can connect a wide range of equipment while maintaining a clean setup.

Durability plays a key role in the DJ150's design, as it is built to withstand the rigors of frequent use. Its robust construction and quality materials contribute to its longevity, appealing to those who value reliable gear.

In conclusion, the York DJ150 represents a versatile solution for DJs seeking a blend of portability, functionality, and sound quality. Its comprehensive features and professional-grade technologies position it as a strong contender in the DJ equipment market, making it suitable for performances of all levels. Whether you are a novice starting your DJ journey or a seasoned pro looking for an efficient tool, the DJ150 ticks all the boxes.