York DJ150 installation manual Rear Duct Dimensions Ductwork, Duct Covers

Page 15

035-19046-002-B-0104

Dot Plugs

 

18-1/4

 

 

 

 

Return

28-1/4

Air

 

Supply

Air

18-1/4

18-1/16

2-31/32

5-5/32

28-1/4

 

31-11/16

FIGURE 9 - REAR DUCT DIMENSIONS

DUCTWORK

Ductwork should be designed and sized according to the methods in Manual D of the Air Conditioning Contractors of America (ACCA) or as recommended by any other recog- nized authority such as ASHRAE or SMACNA.

A closed return duct system should be used. This will not preclude use of economizers or outdoor fresh air intake. The supply and return air duct connections at the unit should be made with flexible joints to minimize noise.

The supply and return air duct systems should be designed for the CFM and static pressure requirements of the job. They should NOT be sized to match the dimensions of the duct connections on the unit.

Refer to Figure 8 for bottom air duct openings. Refer to Fig- ure 9 for rear air duct openings.

DUCT COVERS

Units are shipped with the side duct openings covered and a covering over the bottom of the unit. For bottom duct applica- tion, no duct cover changes are necessary. For side duct application, remove the side duct covers and install over the bottom duct openings. The panels removed from the side duct connections are designed to be reused by securing each panel to its respective downflow opening. But keep in mind that the supply panel is installed with the painted surface UP, facing the heat exchanger, while the return panel is installed with the painted surface DOWN, facing the downflow duct opening. The supply panel is secured with the bracket (already in place from the factory) and two screws. It’s a snug fit for the panel when sliding it between the heat exchanger and unit bottom, but there is room. The return panel is secured with four screws.

Unitary Products Group

15

Image 15
Contents Installation Manual Table of Contents List of Tables List of FiguresSafety Considerations GeneralInspection Reference ApprovalsRenewal Parts Nomenclature 12½ Ton Predator Model Number Nomenclature 150 N15NOMENCLATURE, Additional Options Installation Installation Safety InformationPreceding Installation Limitations Compressor SectionPREDATOR Magnum Component Location Location Unit Temperature LimitationsUnit Voltage Limitations Rigging and HandlingUnit Weights Point Load WeightClearances Detail C Unit DimensionsBottom Duct Openings from Above Duct Covers Rear Duct Dimensions DuctworkPREDATOR Magnum Roof Curb Dimensions Filters Thermostat WiringControl Wire Sizes Power and Control WiringElectronic Thermostat Field Wiring Power Wiring DetailField Wiring 24 Volt Thermostat Contactor 1M Factory or Field Ground MCA Physical Data Optional Electric HeatMinimum Supply AIR CFM Optional GAS Heat GAS Heat Application DataGAS Piping LP UNITS, Tanks and Piping GAS ConnectionFactory Installed Options Field Installed Accessories Minimum Position Adjustment Enthalpy SET Point AdjustmentIndoor AIR Quality AQ Enthalpy SET Point Chart Belt Tension PhasingBlower Rotation Supply AIR LimitationsTurns Open ESP‡ CFM BHP Blower performance includes dry coil and two-inch Method ONE Indoor Blower SpecificationsAIR Balance Checking AIR QuantityDRY Coil Delta P Supply AIR Drive Adjustment Cooling Sequence of Operation OperationAdditional Static Resistance Motor Sheave Datum DiametersNo Outdoor AIR Options Economizer Single or Dual with Power ExhaustCooling Operation Errors HIGH-PRESSURE Limit SwitchCompressor Protection Safety ControlsElectric Heat Anticipator Setpoints Electric Heating Operation ErrorsElectric Heat Limit Setting Electric Heating Sequence of OperationsGAS Heating Operation Errors GAS Heating Sequence of OperationsIgnition Control Board GAS Heat Limit Control Settings START-UP GAS Heat START-UP CoolingChecking GAS Input Post Start ChecklistManifold GAS Pressure Adjustment Shut DownGAS Rate Cubic Feet PER Hour BURNERS/ORIFICES INSPECTION/SERVICING Adjustment of Temperature RiseUnit Control Board Flash Codes TroubleshootingCharging the Unit PREDATOR Magnum Flash CodesBasic Troubleshooting Flowchart Trip Failure Flow Chart Cooling Troubleshooting Guide Unitary Products Group 035-19046-002-B-0104 GAS Heat Troubleshooting Guide Unitary Products Group 035-19046-002-B-0104 Unitary Products Group Unitary 5005 Norman Products York Group Drive 73069

DJ150 specifications

The York DJ150 is a standout model in the world of portable DJ equipment, designed to cater to both budding DJs and seasoned professionals. Its sleek and compact form factor makes it highly portable, allowing for easy transporting to gigs, parties, or personal events.

One of the main features of the DJ150 is its user-friendly interface, which includes a simplified control layout. This design boils down essential functions into accessible buttons and knobs, enabling DJs to focus on their mixes without distractions. The large jog wheels are not only responsive but also provide precision when scratching and cueing tracks, making it a joy to use for both live performances and practice sessions.

In terms of sound quality, the York DJ150 is equipped with high-performance audio circuitry. It ensures that sound clarity is maintained, with a dynamic range that captures the intricacies of music. The device supports multiple audio formats, offering versatility for DJs that work with various types of digital music files.

The DJ150 integrates advanced technologies that facilitate seamless mixing and creative expression. With features such as built-in sound effects, loops, and samples, DJs can add their personal touch to sets. Additionally, the model includes an intelligent beat matching function which automatically syncs the tempo of different tracks, allowing for smooth transitions and uninterrupted flow.

Connectivity is another strong point for the York DJ150. It offers multiple input and output options, including USB ports for quick connections to a laptop or external devices, line inputs for instruments or microphones, and headphones output for monitoring. This ensures that users can connect a wide range of equipment while maintaining a clean setup.

Durability plays a key role in the DJ150's design, as it is built to withstand the rigors of frequent use. Its robust construction and quality materials contribute to its longevity, appealing to those who value reliable gear.

In conclusion, the York DJ150 represents a versatile solution for DJs seeking a blend of portability, functionality, and sound quality. Its comprehensive features and professional-grade technologies position it as a strong contender in the DJ equipment market, making it suitable for performances of all levels. Whether you are a novice starting your DJ journey or a seasoned pro looking for an efficient tool, the DJ150 ticks all the boxes.