York DJ150 installation manual NOMENCLATURE, Additional Options

Page 7

035-19046-002-B-0104

NOMENCLATURE, ADDITIONAL OPTIONS:

AA

None

 

 

AC

Coil Guard

 

 

AD

Dirty Filter Switch

 

 

AG

Coil Guard & Dirty Filter Switch

 

 

CA

CPC Controller with Dirty Filter Switch & Air Proving Switch

 

 

CC

CPC Controller, DFS, APS & Coil Guard

 

 

CE

CPC Controller, DFS, APS & Technicoat Cond. Coil

 

 

CG

CPC Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard

 

 

CJ

CPC Controller, DFS, APS & Technicoat Evap. Coil

 

 

CL

CPC Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard

 

 

CN

CPC Controller, DFS, APS & Technicoat Evap. & Cond Coils

 

 

CQ

CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard

 

 

CV

CPC Controller, DFS, APS, & 2” Pleated Filters

 

 

HA

Honeywell Excel 10 Controller with Dirty Filter Switch & Air Proving Switch

 

 

HC

Honeywell Excel 10 Controller, DFS, APS & Coil Guard

 

 

HE

Honeywell Excel 10 Controller, DFS, APS & Technicoat Cond. Coil

 

 

HG

Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard

 

 

HJ

Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. Coil

 

 

HL

Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard

 

 

HN

Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. & Cond Coils

 

 

HQ

Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard

 

 

JA

Johnson UNT Controller with Dirty Filter Switch & Air Proving Switch

 

 

JC

Johnson UNT Controller, DFS, APS & Coil Guard

 

 

JE

Johnson UNT Controller, DFS, APS & Technicoat Cond. Coil

 

 

JG

Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard

 

 

JJ

Johnson UNT Controller, DFS, APS & Technicoat Evap. Coil

 

 

JL

Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard

 

 

JN

Johnson UNT Controller, DFS, APS & Technicoat Evap. & Cond Coils

 

 

JQ

Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard

 

 

NA

Novar ETC-3 Controller with Dirty Filter Switch & Air Proving Switch

 

 

NC

Novar ETC-3 Controller, DFS, APS & Coil Guard

 

 

NE

Novar ETC-3 Controller, DFS, APS & Technicoat Cond. Coil

 

 

NG

Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard

 

 

NJ

Novar ETC-3 Controller, DFS, APS & Technicoat Evap. Coil

 

 

NL

Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard

 

 

NN

Novar ETC-3 Controller, DFS, APS & Technicoat Evap. & Cond Coils

 

 

NQ

Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard

 

 

TA

Technicoat Condenser Coil

 

 

Unitary Products Group

7

Image 7
Contents Installation Manual Table of Contents List of Tables List of FiguresGeneral Safety ConsiderationsInspection Approvals ReferenceRenewal Parts Nomenclature 12½ Ton Predator Model Number Nomenclature 150 N15NOMENCLATURE, Additional Options Installation Safety Information InstallationPreceding Installation Limitations Compressor SectionPREDATOR Magnum Component Location Location Unit Temperature LimitationsUnit Voltage Limitations Rigging and HandlingPoint Load Weight Unit WeightsClearances Detail C Unit DimensionsBottom Duct Openings from Above Duct Covers Rear Duct Dimensions DuctworkPREDATOR Magnum Roof Curb Dimensions Filters Thermostat WiringControl Wire Sizes Power and Control WiringElectronic Thermostat Field Wiring Power Wiring DetailField Wiring 24 Volt Thermostat Contactor 1M Factory or Field Ground MCA Optional Electric Heat Physical DataMinimum Supply AIR CFM GAS Heat Application Data Optional GAS HeatGAS Piping LP UNITS, Tanks and Piping GAS ConnectionFactory Installed Options Field Installed Accessories Enthalpy SET Point Adjustment Minimum Position AdjustmentIndoor AIR Quality AQ Enthalpy SET Point Chart Belt Tension PhasingBlower Rotation Supply AIR LimitationsTurns Open ESP‡ CFM BHP Blower performance includes dry coil and two-inch Method ONE Indoor Blower SpecificationsAIR Balance Checking AIR QuantityDRY Coil Delta P Supply AIR Drive Adjustment Cooling Sequence of Operation OperationAdditional Static Resistance Motor Sheave Datum DiametersNo Outdoor AIR Options Economizer Single or Dual with Power ExhaustCooling Operation Errors HIGH-PRESSURE Limit SwitchCompressor Protection Safety ControlsElectric Heat Anticipator Setpoints Electric Heating Operation ErrorsElectric Heat Limit Setting Electric Heating Sequence of OperationsGAS Heating Sequence of Operations GAS Heating Operation ErrorsIgnition Control Board GAS Heat Limit Control Settings START-UP GAS Heat START-UP CoolingChecking GAS Input Post Start ChecklistManifold GAS Pressure Adjustment Shut DownGAS Rate Cubic Feet PER Hour BURNERS/ORIFICES INSPECTION/SERVICING Adjustment of Temperature RiseUnit Control Board Flash Codes TroubleshootingCharging the Unit PREDATOR Magnum Flash CodesBasic Troubleshooting Flowchart Trip Failure Flow Chart Cooling Troubleshooting Guide Unitary Products Group 035-19046-002-B-0104 GAS Heat Troubleshooting Guide Unitary Products Group 035-19046-002-B-0104 Unitary Products Group Unitary 5005 Norman Products York Group Drive 73069

DJ150 specifications

The York DJ150 is a standout model in the world of portable DJ equipment, designed to cater to both budding DJs and seasoned professionals. Its sleek and compact form factor makes it highly portable, allowing for easy transporting to gigs, parties, or personal events.

One of the main features of the DJ150 is its user-friendly interface, which includes a simplified control layout. This design boils down essential functions into accessible buttons and knobs, enabling DJs to focus on their mixes without distractions. The large jog wheels are not only responsive but also provide precision when scratching and cueing tracks, making it a joy to use for both live performances and practice sessions.

In terms of sound quality, the York DJ150 is equipped with high-performance audio circuitry. It ensures that sound clarity is maintained, with a dynamic range that captures the intricacies of music. The device supports multiple audio formats, offering versatility for DJs that work with various types of digital music files.

The DJ150 integrates advanced technologies that facilitate seamless mixing and creative expression. With features such as built-in sound effects, loops, and samples, DJs can add their personal touch to sets. Additionally, the model includes an intelligent beat matching function which automatically syncs the tempo of different tracks, allowing for smooth transitions and uninterrupted flow.

Connectivity is another strong point for the York DJ150. It offers multiple input and output options, including USB ports for quick connections to a laptop or external devices, line inputs for instruments or microphones, and headphones output for monitoring. This ensures that users can connect a wide range of equipment while maintaining a clean setup.

Durability plays a key role in the DJ150's design, as it is built to withstand the rigors of frequent use. Its robust construction and quality materials contribute to its longevity, appealing to those who value reliable gear.

In conclusion, the York DJ150 represents a versatile solution for DJs seeking a blend of portability, functionality, and sound quality. Its comprehensive features and professional-grade technologies position it as a strong contender in the DJ equipment market, making it suitable for performances of all levels. Whether you are a novice starting your DJ journey or a seasoned pro looking for an efficient tool, the DJ150 ticks all the boxes.