York DJ150 installation manual Compressor Section, Limitations

Page 9

035-19046-002-B-0104

2.Turn each bracket toward the ground and the protective plywood covering will drop to the ground.

3.Remove the condenser coil external protective covering prior to operation.

4.Remove the toolless doorknobs and instruction packet prior to installation.

Toolless

Doorknobs

Installation

Instruction

Packet

FIGURE 2 - COMPRESSOR SECTION

This product must be installed in strict compliance with the enclosed installation instructions and any applicable local, state and national codes including, but not limited to, building, electrical, and mechani- cal codes.

The furnace and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing at pressures in excess of 1/2 PSIG.

Pressures greater than 1/2 PSIG will cause gas valve damage resulting in a hazardous condition. If it is subjected to a pressure greater than 1/2 PSIG, the gas valve must be replaced.

The furnace must be isolated from the gas supply piping system by closing its individual manual shut- off valve during any pressure testing of the gas sup- ply piping system at test pressures equal to or less than 1/2 PSIG.

LIMITATIONS

These units must be installed in accordance with the follow- ing:

In U.S.A.:

1.National Electrical Code, ANSI/NFPA No. 70 - Latest Edition

2.National Fuel Gas Code, ANSI Z223.1 - Latest Edition

3.Gas-Fired Central Furnace Standard, ANSI Z21.47a. - Latest Edition

4.Local building codes, and

5.Local gas utility requirements

In Canada:

1.Canadian Electrical Code, CSA C22.1

2.Installation Codes, CSA - B149.1.

3.Local plumbing and waste water codes, and

4.Other applicable local codes.

Refer to Tables 1 & 2 for unit application data.

After installation, gas fired units must be adjusted to obtain a temperature rise within the range specified on the unit rating plate.

If components are to be added to a unit to meet local codes, they are to be installed at the dealer’s and/or customer’s expense.

Size of unit for proposed installation should be based on heat loss/heat gain calculation made according to the methods of Air Conditioning Contractors of America (ACCA).

This furnace is not to be used for temporary heating of build- ings or structures under construction.

Unitary Products Group

9

Image 9
Contents Installation Manual Table of Contents List of Tables List of FiguresSafety Considerations GeneralInspection Reference ApprovalsRenewal Parts Nomenclature 12½ Ton Predator Model Number Nomenclature 150 N15NOMENCLATURE, Additional Options Installation Installation Safety InformationPreceding Installation Limitations Compressor SectionPREDATOR Magnum Component Location Unit Voltage Limitations Unit Temperature LimitationsRigging and Handling LocationUnit Weights Point Load WeightClearances Detail C Unit DimensionsBottom Duct Openings from Above Duct Covers Rear Duct Dimensions DuctworkPREDATOR Magnum Roof Curb Dimensions Control Wire Sizes Thermostat WiringPower and Control Wiring FiltersElectronic Thermostat Field Wiring Power Wiring DetailField Wiring 24 Volt Thermostat Contactor 1M Factory or Field Ground MCA Physical Data Optional Electric HeatMinimum Supply AIR CFM Optional GAS Heat GAS Heat Application DataGAS Piping LP UNITS, Tanks and Piping GAS ConnectionFactory Installed Options Field Installed Accessories Minimum Position Adjustment Enthalpy SET Point AdjustmentIndoor AIR Quality AQ Enthalpy SET Point Chart Blower Rotation PhasingSupply AIR Limitations Belt TensionTurns Open ESP‡ CFM BHP Blower performance includes dry coil and two-inch AIR Balance Indoor Blower SpecificationsChecking AIR Quantity Method ONEDRY Coil Delta P Supply AIR Drive Adjustment Additional Static Resistance OperationMotor Sheave Datum Diameters Cooling Sequence of OperationCooling Operation Errors Economizer Single or Dual with Power ExhaustHIGH-PRESSURE Limit Switch No Outdoor AIR OptionsCompressor Protection Safety ControlsElectric Heat Limit Setting Electric Heating Operation ErrorsElectric Heating Sequence of Operations Electric Heat Anticipator SetpointsGAS Heating Operation Errors GAS Heating Sequence of OperationsIgnition Control Board GAS Heat Limit Control Settings START-UP GAS Heat START-UP CoolingManifold GAS Pressure Adjustment Post Start ChecklistShut Down Checking GAS InputGAS Rate Cubic Feet PER Hour BURNERS/ORIFICES INSPECTION/SERVICING Adjustment of Temperature RiseCharging the Unit TroubleshootingPREDATOR Magnum Flash Codes Unit Control Board Flash CodesBasic Troubleshooting Flowchart Trip Failure Flow Chart Cooling Troubleshooting Guide Unitary Products Group 035-19046-002-B-0104 GAS Heat Troubleshooting Guide Unitary Products Group 035-19046-002-B-0104 Unitary Products Group Unitary 5005 Norman Products York Group Drive 73069

DJ150 specifications

The York DJ150 is a standout model in the world of portable DJ equipment, designed to cater to both budding DJs and seasoned professionals. Its sleek and compact form factor makes it highly portable, allowing for easy transporting to gigs, parties, or personal events.

One of the main features of the DJ150 is its user-friendly interface, which includes a simplified control layout. This design boils down essential functions into accessible buttons and knobs, enabling DJs to focus on their mixes without distractions. The large jog wheels are not only responsive but also provide precision when scratching and cueing tracks, making it a joy to use for both live performances and practice sessions.

In terms of sound quality, the York DJ150 is equipped with high-performance audio circuitry. It ensures that sound clarity is maintained, with a dynamic range that captures the intricacies of music. The device supports multiple audio formats, offering versatility for DJs that work with various types of digital music files.

The DJ150 integrates advanced technologies that facilitate seamless mixing and creative expression. With features such as built-in sound effects, loops, and samples, DJs can add their personal touch to sets. Additionally, the model includes an intelligent beat matching function which automatically syncs the tempo of different tracks, allowing for smooth transitions and uninterrupted flow.

Connectivity is another strong point for the York DJ150. It offers multiple input and output options, including USB ports for quick connections to a laptop or external devices, line inputs for instruments or microphones, and headphones output for monitoring. This ensures that users can connect a wide range of equipment while maintaining a clean setup.

Durability plays a key role in the DJ150's design, as it is built to withstand the rigors of frequent use. Its robust construction and quality materials contribute to its longevity, appealing to those who value reliable gear.

In conclusion, the York DJ150 represents a versatile solution for DJs seeking a blend of portability, functionality, and sound quality. Its comprehensive features and professional-grade technologies position it as a strong contender in the DJ equipment market, making it suitable for performances of all levels. Whether you are a novice starting your DJ journey or a seasoned pro looking for an efficient tool, the DJ150 ticks all the boxes.