What is in this manual?

Service

The Armor X2 water heater display

• Display panel readout, buttons and their functions

Control module inputs

• Control module inputs and options

Control module outputs

• Control module outputs and options

General

How the water heater operates

How the control module operates

Access modes -- user and installer

Sequence of operation -- Water Heating

Control panel menu access

Accessing programming mode and locating menus (See separate guide covering the PC interface.)

Control panel parameter access

• Accessing and changing parameters from the display panel

Quick start information -- parameter table

An index of available adjustments and readouts, where to access them and where to find detailed information.

Armor X2 water heater operation

Setup

Service / Setup

Setpoint

Night Setback

Cascade

Pumps

BMS

Service Manual

Maintenance

Service and maintenance schedules

Address reported problems

Inspect water heater area and water heater interior

Clean condensate trap

Check all piping for leaks

Check air openings

Flue vent system and air piping

Check water system

Check water heater relief valve

Inspect ignition electrode

Check ignition ground wiring

Check all water heater wiring

Check control settings

Perform start-up and checks

Check burner flame

Check flame signal

Check flue gas temperature

General maintenance

Review with owner

Cleaning the water heater heat exchanger

Oiled bearing circulators

Troubleshooting

Troubleshooting table - No display

Checking temperature sensors

Sensor tables

Troubleshooting table - Fault messages displayed on the water heater interface

Combustion analysis procedure

Gas valve adjustment procedure

4

Image 4
Contents Models 1.0, 1.3, Contents Handling ceramic fiber materials Niosh stated First AidMaintenance ServiceTroubleshooting Armor X2 display Control inputs Primary Smart Control ModuleSecondary Smart Touch Control Module Primary Control outputsHow the water heater operates General OperationSequence of operation Sequence of operation Sequence of operationThis table lists the parameters and where to access them Parameter tableBMS Viewable and changeable control parameters Status ScreenService Details Screen Service Main Screen Setup Screen Service/Setup Parameters Screen Service Set Point Parameters Screen Night Setback Parameters Screen Cascade Parameters Screen Cascade Operation10Vdc BMS Parameters Screen 10Vdc OperationService Cascade Screen Service Temps Screen Burners Screen Graph Select Screen History Screen Service Mode Screen Maintenance Maintenance and annual startup Address reported problems Clean condensate trapInspect water heater area Inspect water heater interiorCheck water system Flue vent system and air pipingCheck expansion tank Check water heater relief valve Check ignition ground wiring Check all water heater wiringCheck control settings Check flame signalCheck Delta T Cleaning water heater heat exchangerOiled bearing circulators Troubleshooting Alarm ScreenCheck the following Before troubleshootingCheck control module fuses Troubleshooting Checking temperature sensors Temperature ResistanceFault Cause Corrective Action Flow Switch CondensateDrain Blocked Flame outFlame Lost Light cont’dWhile Running Cont’d Manual ResetHigh Limit Automatic Reset High Limit / HEXTemp SW Blower RPM’sLouver Proving Switch Too HighSensor Open Sensor ShortedResets Try Later Air Flow TooLow Flap ValveInternal Fault No Error StoredWriting to MemosCombustion Analysis Procedure Gas Valve AdjustmentOr Obstruction Gas Supply PressureModel Gas valve adjustment procedureModels 1.3