Lochinvar 1.3, 1.5 service manual Light cont’d, Flame Lost, While Running

Page 43

Service Manual

3 Troubleshooting (continued)

Table 3E (continued from previous page) Troubleshooting Chart - Fault Messages Displayed on Water Heater Interface

FAULT

DESCRIPTION

 

 

CORRECTIVE ACTION

 

 

 

 

 

 

 

 

• If 24 VAC is present at the main control board, check

 

 

 

the wiring between the main control board and the gas

 

 

 

valve. Replace the wiring if necessary. Do not

 

 

 

disconnect the wiring from the gas valve and attempt

 

 

 

to measure voltage at that point. The main control

 

 

 

board can detect if the gas valve is not connected and

 

 

 

will display the Gas Valve / Connection fault.

 

 

 

 

• If 24 VAC is present, check the outlet of the valve to

Burner Did Not

 

 

ensure the valve is flowing gas. With a manometer

 

 

connected to the outlet tap of the gas valve, when the

Light (cont’d)

 

 

The unit has failed to prove main

burner

unit is in the prepurge period, there should be a

(will require a manual

negative pressure present. When the valve is

reset once the condition

ignition. It will require a manual reset before

energized a change in pressure should occur. If the

has been corrected.

attempting to fire again.

 

 

pressure change does not occur, the gas valve is not

Press the RESET button

 

 

 

 

opening. Replace the gas valve.

 

 

 

 

on the display to reset.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Inspect flame sensor and associated wiring.

 

 

 

Reference page 35 of this manual for removal and

 

 

 

cleaning procedures. Replace if necessary.

 

 

 

 

• Inspect the burner. Reference page 35 of this manual

 

 

 

for removal and cleaning procedures. Replace if

 

 

 

necessary.

 

 

 

 

 

 

 

 

• Replace the main control board.

 

 

 

 

 

 

 

 

 

 

 

• Inspect spark electrode and associated wiring for

 

 

 

damage and connection. Reference page 35 of this

 

 

 

manual for removal and cleaning procedures.

 

 

 

Replace if necessary.

 

 

 

 

 

 

 

• Check for proper electrical grounding of unit.

 

 

 

 

• Check incoming supply gas pressure. Natural gas

 

 

 

pressures should be between 4 -

14

inches

w.c.

Flame Lost

 

 

(1.0 -

3.5

kPa) and LP gas pressures

should be

 

 

between 8

- 14 inches w.c.

(2.0

-

3.2

kPa).

While Running

 

 

The unit was running and lost the

flame

Refer to Section 7 - Gas Connections of the Armor X2

(will require a manual

Installation and Operation Manual for detailed

reset once the condition

signal. This condition occurred twice .

information concerning the gas supply.

 

 

 

has been corrected.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press the RESET button

 

 

• Verify

that

the tube from the gas valve

to the air

on the display to reset.)

 

 

 

 

inlet is connected and is not damaged.

 

 

 

 

 

 

 

 

 

 

 

 

• Verify that the vent/air intake pipes are installed

 

 

 

correctly and there are no obstructions.

 

 

 

 

 

 

• Check for 24 VAC to the gas valve at the 2-pin

 

 

 

connection on the side of the main control board

 

 

 

during the ignition attempt. If no voltage is present,

 

 

 

replace the main control board.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

43

Image 43
Contents Models 1.0, 1.3, Contents Niosh stated First Aid Handling ceramic fiber materialsMaintenance ServiceTroubleshooting Armor X2 display Primary Smart Control Module Control inputsControl outputs Secondary Smart Touch Control Module PrimaryHow the water heater operates General OperationSequence of operation Sequence of operation Sequence of operationParameter table This table lists the parameters and where to access themBMS Status Screen Viewable and changeable control parametersService Details Screen Service Main Screen Setup Screen Service/Setup Parameters Screen Service Set Point Parameters Screen Night Setback Parameters Screen Cascade Operation Cascade Parameters Screen10Vdc Operation 10Vdc BMS Parameters ScreenService Cascade Screen Service Temps Screen Burners Screen Graph Select Screen History Screen Service Mode Screen Maintenance Maintenance and annual startup Inspect water heater interior Address reported problemsClean condensate trap Inspect water heater areaCheck water system Flue vent system and air pipingCheck expansion tank Check water heater relief valve Check flame signal Check ignition ground wiringCheck all water heater wiring Check control settingsCheck Delta T Cleaning water heater heat exchangerOiled bearing circulators Alarm Screen TroubleshootingCheck the following Before troubleshootingCheck control module fuses Troubleshooting Temperature Resistance Checking temperature sensorsFault Cause Corrective Action Flame out Flow SwitchCondensate Drain BlockedFlame Lost Light cont’dWhile Running Cont’d Manual ResetHigh Limit Blower RPM’s Automatic ResetHigh Limit / HEX Temp SWSensor Shorted Louver Proving SwitchToo High Sensor OpenFlap Valve Resets Try LaterAir Flow Too LowMemos Internal FaultNo Error Stored Writing toGas Supply Pressure Combustion Analysis ProcedureGas Valve Adjustment Or ObstructionModel Gas valve adjustment procedureModels 1.3