Lochinvar 1.5, 1.3 service manual Maintenance Maintenance and annual startup

Page 32

Service Manual

2 Maintenance

Maintenance and annual startup

Table 2A Service and Maintenance Schedules

Service technician

(see the following pages for instructions)

 

General:

 

 

 

• Address reported problems

 

• Inspect interior; clean and vacuum if

 

necessary;

 

 

 

• Clean condensate trap and fill with fresh

 

water

 

 

 

• Check for leaks (water, gas, flue,

 

condensate)

 

 

 

• Verify flue and air lines in good condition

 

and sealed tight

 

 

 

• Check system

water

pressure/system

UP-

piping/expansion tank

 

• Check control settings

 

 

 

START

• Check ignition and flame sense

electrodes (sand off any deposits; clean

 

ANNUAL

and reposition)

 

 

• Check wiring and connections

 

 

• Perform start-up checkout and

 

performance verification per Section 9

 

in the Armor X2 Installation and

 

Operation Manual.

 

 

• Flame inspection (stable, uniform)

 

• Flame signal (at least 10 microamps at

 

high fire)

 

 

 

•Clean the heat exchanger if flue

 

temperature is more than 54°F (30°C)

 

above return water temperature.

 

• Test low water flow conditions.

 

If combustion

or

performance

 

indicate need:

 

 

Clean heat exchanger

Remove and clean burner using compressed air only

Clean the blower wheel

Owner maintenance

 

• Check water heater area

Daily

• Check pressure/temperature

 

gauge

 

• Check vent piping

Monthly

• Check air piping

 

• Check air and vent termination

 

screens

 

• Check relief valve

 

• Check condensate drain system

 

• Check automatic air vents

Every

6 months

Check water heater piping (gas and water) for leaks

Operate relief valve

32

Image 32
Contents Models 1.0, 1.3, Contents Handling ceramic fiber materials Niosh stated First AidTroubleshooting ServiceMaintenance Armor X2 display Control inputs Primary Smart Control ModuleSecondary Smart Touch Control Module Primary Control outputsSequence of operation General OperationHow the water heater operates Sequence of operation Sequence of operationThis table lists the parameters and where to access them Parameter tableBMS Viewable and changeable control parameters Status ScreenService Details Screen Service Main Screen Setup Screen Service/Setup Parameters Screen Service Set Point Parameters Screen Night Setback Parameters Screen Cascade Parameters Screen Cascade Operation10Vdc BMS Parameters Screen 10Vdc OperationService Cascade Screen Service Temps Screen Burners Screen Graph Select Screen History Screen Service Mode Screen Maintenance Maintenance and annual startup Address reported problems Clean condensate trapInspect water heater area Inspect water heater interiorCheck expansion tank Check water heater relief valve Flue vent system and air pipingCheck water system Check ignition ground wiring Check all water heater wiringCheck control settings Check flame signalOiled bearing circulators Cleaning water heater heat exchangerCheck Delta T Troubleshooting Alarm ScreenCheck control module fuses Before troubleshootingCheck the following Troubleshooting Checking temperature sensors Temperature ResistanceFault Cause Corrective Action Flow Switch CondensateDrain Blocked Flame outWhile Running Light cont’dFlame Lost High Limit Manual ResetCont’d Automatic Reset High Limit / HEXTemp SW Blower RPM’sLouver Proving Switch Too HighSensor Open Sensor ShortedResets Try Later Air Flow TooLow Flap ValveInternal Fault No Error StoredWriting to MemosCombustion Analysis Procedure Gas Valve AdjustmentOr Obstruction Gas Supply PressureModels 1.3 Gas valve adjustment procedureModel
Related manuals
Manual 16 pages 3.68 Kb Manual 12 pages 30.87 Kb Manual 56 pages 20.39 Kb Manual 20 pages 6.19 Kb Manual 16 pages 33.86 Kb Manual 56 pages 40.75 Kb Manual 80 pages 59.46 Kb Manual 56 pages 36.01 Kb

1.5, 1.3, 1 specifications

Lochinvar 1 is a remarkable achievement in the realm of modern technology and engineering. As a powerful and efficient water heater, it has been designed to cater to a wide range of residential and commercial needs. One of the standout features of Lochinvar 1 is its advanced heating technology, which incorporates a high-efficiency condensing design. This technology allows the unit to achieve impressive energy savings by maximizing heat transfer while minimizing energy consumption.

The Lochinvar 1 utilizes a stainless steel heat exchanger that enhances durability and corrosion resistance. This not only extends the lifespan of the unit but also ensures consistent performance over time. Coupled with a user-friendly control system, users can easily adjust settings and monitor performance, enhancing overall convenience and usability.

Another key characteristic of the Lochinvar 1 is its compact design, making it suitable for a variety of installation environments. Whether in a residential basement or a commercial utility room, the unit’s space-saving configuration allows for efficient use of available area without compromising on capability.

Safety features are integral to the Lochinvar 1, providing peace of mind for users. The unit is equipped with advanced monitoring systems that can detect irregularities and automatically shut down the system if necessary. This not only protects the equipment but also enhances the safety of the environment in which it operates.

In terms of performance, Lochinvar 1 boasts a high recovery rate, ensuring hot water is available on demand. This is particularly beneficial for settings with high water usage, allowing simultaneous operations without lag.

Moreover, the unit supports various venting options, offering flexibility during installation. Whether using traditional vertical venting or innovations like direct venting, Lochinvar 1 accommodates different building designs and local codes, making it highly versatile.

In conclusion, Lochinvar 1 epitomizes the melding of efficiency, reliability, and user-friendly technology. With its high-performance features, robust safety systems, and adaptable installation options, it stands out as a forefront player in the water heating industry, meeting the diverse needs of today's consumers and businesses alike.