Service Manual
3 Troubleshooting (continued)
Table 3E (continued from previous page) Troubleshooting Chart - Fault Messages Displayed on Water Heater Interface
FAULT | DESCRIPTION | CORRECTIVE ACTION | |
| Air pressure switch contacts are open. | • Check the wiring connections to switch. Wires should | |
|
| be connected to the common and normally closed | |
|
| terminals. | |
|
| • Vent/air intake lengths exceed the maximum allowed | |
|
| lengths. Refer to Section 3 - General Venting of the | |
|
| Armor X2 Installation and Operation Manual for | |
|
| proper lengths. | |
|
| • Check for obstruction or blockage in the vent/air | |
|
| intake pipes or at terminations. | |
|
| • Check reference hoses connected to the air pressure | |
Air Flow Too |
| switch for blockage or obstruction. | |
Low |
| • Inspect the burner. Reference page 35 of this manual | |
(will require a manual |
| for removal and cleaning procedures. Replace if | |
reset once the condition |
| necessary. | |
has been corrected. |
| • Inspect the heat exchanger. Reference page 36 of | |
Press the RESET button |
| ||
on the display to reset.) |
| this manual for removal and cleaning procedures. | |
|
| Replace if necessary. | |
|
| • Faulty air pressure switch. Replace switch. | |
|
|
| |
|
| • Check the wiring connections to the flap valve switch. | |
|
| Replace or repair wiring if necessary. | |
|
| • Check for obstruction in the vent / air intake pipes or | |
| Flap valve contacts are in an open position. | at terminations. | |
|
| ||
|
| • Verify combustion air blower is operating. Replace if | |
|
| necessary. | |
|
| • Replace flap valve switch. | |
|
|
| |
|
| • Check wiring connections to the flap valve switch. | |
Flap Valve |
| Replace or repair wiring if necessary. | |
Flap valve contacts are in a closed position. |
| ||
Stuck Open | • Check flap valve for obstruction or blockage. | ||
|
| • Replace flap valve switch. | |
|
|
| |
Too Many | Too many manual resets have occurred | • Wait 15 minutes and try again. | |
• Turn power off to unit, wait 30 seconds and then turn | |||
Resets - Try Later | during a 15 minute period. | ||
|
| power back on. | |
|
|
| |
|
| • Check 120 VAC supply to the transformer. | |
Voltage Too |
| • Check wiring connections at the low voltage terminal | |
120 VAC input to the main control board has | strip. | ||
Low |
| ||
dropped below 80 VAC. | • Check the wire size/length to remote devices. | ||
| |||
|
| ||
|
| • Replace the main control board. | |
|
|
|