ANODE ROD INSPECTION

ANODE ROD INSPECTION

 

DRAINING

The anode rod is used to protect the tank from corrosion. Most hot water tanks are equipped with an anode rod. The submerged rod sacrifices itself to protect the tank. Instead of corroding the tank, water ions attack and eat away the anode rod. This does not affect the water’s taste or color. The rod must be maintained to keep the tank in operating condition.

Anode deterioration depends on water conductivity, not necessarily water condition. A corroded or pitted anode rod indicates high water conductivity and should be checked and/or replaced more often than an anode rod that appears to be intact. Replacement of a depleted anode rod can extend the life of your water heater. Inspection should be conducted by a qualified technician, and at a minimum should be checked annually after the warranty period.

TEMPERATURE-PRESSURE

RELIEF VALVE OPERATION

The temperature-pressure relief valve must be manually operated at least once a year.

FIGURE 30.

When checking the temperature-pressure relief valve operation, make sure that (1) no one is in front of or around the outlet of the temperature-pressure relief valve discharge line, and (2) that the water discharge will not cause any property damage, as the water may be extremely hot, see Figure 30.

If after manually operating the valve, it fails to completely reset and continues to release water, immediately close the cold water inlet to the water heater, follow the draining instructions, and replace the temperature-pressure relief valve with a new one.

Ifthetemperature-pressurereliefvalveontheapplianceweepsordischarges periodically, this may be due to thermal expansion. You may have a check valve installed in the water line or a water meter with a check valve. Consult your local water supplier or Maytag Customer Service (1-800-788-8899) for further information. Do not plug the temperature-pressure relief valve.

The water heater should be drained if being shut down during freezing temperatures. Also periodic draining and cleaning of sediment from the tank may be necessary.

1.Set the blower switch to the “OFF” position.

2.CLOSE the cold water inlet valve to the water heater.

3.OPEN a nearby hot water faucet and leave open to allow for draining.

4.Connect a hose to the drain valve and terminate to an adequate drain.

5.OPEN the water heater drain valve to allow for tank draining.

NOTE: If the water heater is going to be shut down and drained for an extended period, the drain valve should be left open with hose connected allowing water to terminate to an adequate drain.

6.CLOSE the drain valve.

7.Follow instructions in the “Filling The Water Heater” section.

8.Follow the lighting instructions on the label or see page 23 under “Operating Instructions” to restart the water heater.

DRAIN VALVE WASHER REPLACEMENT

(See Figure 31)

1.Turn “OFF” gas supply to water heater.

2.Follow “Draining” instructions.

3. Turning counterclockwise (

), remove the hex cap below the

screw handle.

 

4.Remove the washer and put the new one in place.

5.Screw the handle and cap assembly back into the drain valve and retighten using a wrench. DO NOT OVER TIGHTEN.

6.Follow instructions in the “Filling The Water Heater” section.

7.Check for leaks.

8.Follow the lighting instructions in the “Operating Instructions” section to restart the water heater.

FIGURE 31.

SERVICE

If a condition persists or you are uncertain about the operation of the water heater contact Maytag Customer Service at 1-800-788-8899 for an authorized servicer.

27

Image 27
Contents Series Twelve POWER VENT GAS WATER HEATER USER’S GUIDEIMPORTANT DEFINITIONS SAFE INSTALLATION, USE AND SERVICESAFETY PRECAUTIONS TABLE OF CONTENTS PRODUCT SPECIFICATIONS CUSTOMER RESPONSIBILITIESPREPARING FOR THE INSTALLATION Tools MATERIALS AND BASIC TOOLS NEEDEDAccessories Additional Tools Needed When Sweat Soldering2, 3 OR 4 PVC VENT CAPABILITY TYPICAL INSTALLATIONGET TO KNOW YOUR WATER HEATER - GAS MODELS GAS MODELS WITH HOT SURFACE IGNITIONTYPICAL INSTALLATION MIXING VALVE USAGEFIGURE2 Removing the Old Water Heater INSTALLATION INSTRUCTIONSFIGURE9 FACTS TO CONSIDER ABOUT THE LOCATIONINSULATION BLANKETS FIGURE15 FIGURE12FIGURE13 FIGURE14WATER PIPING TEMPERATURE-PRESSURERELIEF VALVE T & P Valve and Pipe Insulation if suppliedFIGURE17 GAS PIPING FIGURE 18. GAS PIPING WITH FLEXIBLECONNECTORFILLING THE WATER HEATER BLOWER ASSEMBLY INSTALLATIONSEQUENCEOFINSTALLATION SEDIMENT TRAPSVENT CONNECTIONS TO BLOWER ASSEMBLY VENTING AND INSTALLATIONFIGURE21 50,000 BTU Units CONDENSATIONMAXIMUM VENT LENGTHS 40,000 BTU UnitsVENT TERMINAL INSTALLATION VENTINGFIGURE22 FIGURE24 VERTICAL VENT THROUGH ROOFVERTICAL VENT RESTRICTIONS FIGURE23VENT PIPE PREPARATION RECOMMENDED BRUSH* SIZE FOR PRIMERAND CEMENT APPLICATIONS B.Deburring D.Inspection, cleaning, primingSTEPE F. Joint assembly STEPF G. Cleanup and joint movementTO TURN OFF GAS TO APPLIANCE OPERATING INSTRUCTIONSFOR YOUR SAFETY READ BEFORE OPERATING OPERATING INSTRUCTIONSFIGURE26 TEMPERATURE REGULATIONFOR YOUR INFORMATION START UP CONDITIONSOPERATIONAL CONDITIONS BURNER OPERATION AND INSPECTION SERVICE AND ADJUSTMENTBURNER CLEANING VENTING SYSTEM INSPECTIONDRAINING DRAIN VALVE WASHER REPLACEMENTSERVICE ANODE ROD INSPECTIONLEAKAGE CHECKPOINTS WATER HEATER CONTROL TROUBLESHOOTING GUIDELINESPROBLEM SOLUTIONThese guidelines should be used by a qualified Maytag Customer Service Center Agent. Call the Maytag Customer Service Center at TROUBLESHOOTING GUIDELINESTHIS IS A REPAIR PARTS LIST, NOT A PACKING LIST REPAIR PARTS LISTLIMITED TANK WARRANTY AGAINST LEAKS WARRANTYFULL ONE YEAR WARRANTY LIMITED PARTS WARRANTY