CUSTOMER RESPONSIBILITIES
Thank You for purchasing a Maytag water heater. Properly installed and maintained, it should give you years of trouble free service. It is strongly suggested that this new water heater be professionally installed, contact Maytag Customer Service
Abbreviations Found In This Instruction Manual:
•CSA - Canadian Standards Association
•ANSI
•ASME - American Society of Mechanical Engineers
•UL - Underwriters Laboratories Inc.
This
PREPARING FOR THE INSTALLATION
1.Read the “Safety Precautions” section, page 3 of this manual first and then the entire manual carefully. If you don’t follow the safety rules, the water heater will not operate properly. It could cause
DEATH,SERIOUSBODILYINJURYAND/ORPROPERTYDAMAGE.
This manual contains instructions for the installation, operation, and maintenance of the
of the water heater and your safety. Since we cannot put everything on the first few pages, READ THE ENTIRE MANUAL BEFORE
ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER.
2.The installation must conform with these instructions and the local code authority having jurisdiction. In the absence of local codes, installations shall comply with the Natural Gas and Propane Installation Code CAN/CSA B149.1 and The Canadian Electric Code CSA C22.1. These publications are available from Canadian Standards Association, 5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5N6.
3.The water heater when installed must be grounded in accordance with the local codes, or in the absence of local codes, the Canadian Electric Code CSA C22.1.
4.If after reading this manual you have any questions or do not understand any portion of the instructions, call the local gas utility or
Maytag Customer Service at
5.Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe installation are very important in preventing death from possible carbon monoxide poisoning and fires.
Examine the location to ensure the water heater complies with the “Facts to Consider About the Location” section in this manual.
PRODUCT SPECIFICATIONS
| TANK |
|
| RECOVERY | MINIMUM |
|
|
| CAPACITY |
| INPUT | RATE GALS. | VENTPIPE | DIAMETER | DIMENSIONSIN |
MODEL | IN GALS. | TYPEOF | RATE | PERHOUR | INCHES | INCHES | INCHES(mm)HEIGHT |
NUMBER | (LTRS) | GAS | (Btu/hr) | @ 90°F RISE | (mm) | (mm) | TOJACKETTOP |
|
|
|
|
|
|
|
|
HVN41240PCGA | 40 (151) | NATURAL | 40,000 | 44 | 2 (51) | 20 1/2 (521) | 55 (1,397) |
|
|
|
|
|
|
|
|
HVN41250PCGA | 50 (189) | NATURAL | 40,000 | 44 | 2 (51) | 22 (559) | 56 3/4 (1,441) |
|
|
|
|
|
|
|
|
HVN41250VCGA | 50 (189) | NATURAL | 50,000 | 53 | 2 (51) | 22 (559) | 56 3/4 (1,441) |
|
|
|
|
|
|
|
|
HVP41240PCGA | 40 (151) | PROPANE | 40,000 | 44 | 2 (51) | 20 1/2 (521) | 55 (1,397) |
|
|
|
|
|
|
|
|
HVP41250PCGA | 50 (189) | PROPANE | 40,000 | 44 | 2 (51) | 22 (559) | 56 3/4 (1,441) |
|
|
|
|
|
|
|
|
HVP41250VCGA | 50 (189) | PROPANE | 50,000 | 53 | 2 (51) | 22 (559) | 56 3/4 (1,441) |
|
|
|
|
|
|
|
|
5