GE AJCM 08 ACD MEASURE,PANELS CUT and Install Filler, Mark the a and B measurements on each side

Page 19

Installation Instructions

6 MEASURE,PANELS CUT AND INSTALL FILLER

AMeasure from the edge of the panel marks (see Prepare the Window) to the inside of the window track on each side (A and B).

Sill

Window track

Outside

13381338

A Width of the air B

 

 

 

Inside

conditioner

 

 

 

Left side

Right side

(panel marks)

 

BMark the A and B measurements on each side

of the filler panel board. Cut the panels and discard the center piece. Note position of the notches.

B

A

Right

Left side

side

(holes areontheright)

onare(holesthe left)

 

Filler Panels

 

Cut panels

 

and discard

 

center piece

CPut together the panel assemblies. Remove the paper backing from the case-side gasket and attach it to the angle. Push a pencil point through the gaskets to locate the holes in the angles.

Gasket

Angle

Angle

Type C

(painted

screws)

GasketPanel

Tab

DInstall the panels in the window. Place the spring clips 3from the top and the bottom. Squeeze and push the clips to fit in the window track and the tab into the sill support.

3

Hook the tab into the sill support

19

Image 19
Contents Model # Installation InstructionsManufacturer and not repaired. Do New power supply cord obtained fromEither the plug or connector end Before making any repairs or cleaningInstructions Operating Instructions We strongly recommend against the use of an extension cordWe strongly recommend against the use of an adapter plug GEAppliances.comConsumer Remote Control Cleaning Operating Instructions Safety InstructionsAbout the controls on the air conditioner-Cool Only Models Remote Control SafetyCooling Descriptions FAN Speeds Consumer Support Remote ControlAbout the controls on the air conditioner-Heat/Cool Models Appearance may varyHeating Descriptions Tips Consumer SupportAbout the controls on the air conditioner Thermostat connections provide 24 V AC only Front Grille Care and cleaning of the air conditionerGrille and Case Outdoor CoilsHow to Insert the Batteries in the Remote Control Safety Air FilterConsumer Support Model Qualifying Questions Amp time delay fuse or circuit breakerBefore YOU Begin ELECTRICAL REQUIREMENTSGE KIT Numbers Tools YOU MAY NeedRemove ALL Shipping Pads Remove Locking Plate on Front Left SideAttach Front Grille Support Requirements for AIR Conditioner Prepare Opening in WallWindow Requirements Window INSTALLATION-OPTIONALRemove AIR Conditioner from Case Prepare Window Install Sill SupportsMark the a and B measurements on each side MEASURE,PANELS CUT and Install FillerCase should have a 1/8″ minimum tilt toward the outside Install Case in WindowReplace AIR Conditioner in Case Install Window Gasket and Locking BracketNormal Operating Sounds Consumer Support Before you call for service…Operating Instructions Safety Instructions CleaningGE Will Replace Air Conditioner WarrantyCleaning Installation Instructions Troubleshooting Tips Consumer SupportReal Life Design Studio Schedule ServiceParts and Accessories Consumer Support GE Appliances Website