HOT KEY

ENGLISH

Mode

Button

Display

Function

Hot key

Up

 

To adjust set point temperature press arrows up or

 

 

 

down.

 

 

 

Results: The temperature can be set ranges from

 

 

 

5°C to 55°C and be adjusted by 0.5°C.

 

 

 

 

 

Down

 

 

 

 

 

 

 

DHW

 

When DHW mode is enabled, it is assured that the

 

 

 

full capacity of the heat pump is used for domestic

 

 

 

water heating only.

 

 

 

Results: The heat pump is operating for the

 

 

 

domestic water only.

 

 

 

 

 

Outing

 

Lowers each target temperature of operation modes

 

 

 

with pre-defined values stored in the Field Setting

 

 

 

Value sector of Wired Remote Controller. Keeps the

 

 

 

house at lower temperature to save your running

 

 

 

cost, you can use this button while having a vacation.

 

 

 

 

Checking the function _11

Image 11
Contents F I P D DB98-32035A2 Air to Water Heat Pump Hydro UnitRunning Costs-Reduction of Up to 33.3% High Performance at Low TemperatureQuick Heating by TDM Technology Integrated Heating & Cooling System at a Lower CostContents Important safety symbols and precautions Safety precautionsFor Using This may result in harm to humans, animals or plants Safety informationControl Panel OverviewSpace Operation Mode Checking the function of buttons and indicatorsDHW DHW Operation ModeDisplay Function Temperature AdjustmentHOT KEY Schedule Mode Status Display Function Status IndicatorA2A Optional Function IndicatorOperating basic function Available ModeSpace Heating Operation Space Cooling Operation Water LAW Domestic Water Heating Operation Operating hot key function Urgent DHW ModeTo cancel the DHW mode To cancel the outing mode Outing ModeOperating advanced function Setting the TimeSet, Cancel/Delete button Setting the 7-DAYWEEKLY ScheduleViewing the 7-dayWeekly Schedule On / Off Display Deleting the 7-dayWeekly schedule Setting the Daily Schedule Viewing the Daily Schedule On / Off Display Operating the daily schedule Deleting the daily scheduleSetting the Field Setting Value of wired remote controller Field Setting ModeField Setting Value Field Setting ValueFSV TableDHW BUH/BSH Priority DHW Heating Remote Controller Setting Range CodeSpace Cooling Space HeatingWater Law for Heating Water Law & Room Thermostat CodeExternal Room Thermostat Field Option Water Law for CoolingDHW Heating Code Heat Pump Variables for Controlling DHW Tank DHW Application#3033 Disinfection Function Booster Heater Variables for Controlling DHW TankHeat Pump Variables for Space Heating Space Heating CodeExternal Backup Boiler for Space Heating Field Option Backup Heater Variables for Space HeatingTDMTime-Division Multi Variables Outing Mode Hot Key of Wired Remote ControllerOthers Code Economic DHW HeatingAvailable operation range Temperature TableDIP Switch Setting AppendixMaintaining the Unit Maintenance activitiesThermistor Troubleshooting TipsE654 TroubleshootingCommunication E912 Water pump & Flow S/WE911 Disposal Requirements Memo 50Memo Memo