Samsung NH200WHXEA, NH200WHXES Deleting the daily schedule, Operating the daily schedule

Page 28

Operating advanced function

SETTING THE DAILY SCHEDULE

Deleting the daily schedule

1.Select the schedule from Reservation View Mode.

2.Push the Cancel/Delete button for 3 seconds.

3.The LCD pictures change to the reservation mode after deleting the schedule.

Operating the daily schedule

1.Operate automatically according to schedule.

2.If On schedule starts during the Urgent DHW mode, the Urgent DHW mode will be turned off.

In the following conditions, the schedule function will not operate.

Outing

Tracking of communication

Installation of room thermostat

If the field setting is set for without DHW or another manufacturers tank is used, its not possible to reserve DHW mode.

If the field setting is set for not using the booster heater, its not possible to reserve Pwr DHW mode.

28_ Operating advanced function

Image 28
Contents Air to Water Heat Pump Hydro Unit F I P D DB98-32035A2High Performance at Low Temperature Quick Heating by TDM TechnologyIntegrated Heating & Cooling System at a Lower Cost Running Costs-Reduction of Up to 33.3%Contents Safety precautions Important safety symbols and precautionsFor Using Safety information This may result in harm to humans, animals or plantsOverview Control PanelChecking the function of buttons and indicators Space Operation ModeDHW Operation Mode DHWTemperature Adjustment Display FunctionHOT KEY Schedule Status Indicator Mode Status Display FunctionOptional Function Indicator A2AAvailable Mode Operating basic functionSpace Heating Operation Space Cooling Operation Water LAW Domestic Water Heating Operation To cancel the DHW mode Urgent DHW ModeOperating hot key function Outing Mode To cancel the outing modeSetting the Time Operating advanced functionSetting the 7-DAYWEEKLY Schedule Set, Cancel/Delete buttonViewing the 7-dayWeekly Schedule On / Off Display Deleting the 7-dayWeekly schedule Setting the Daily Schedule Viewing the Daily Schedule On / Off Display Deleting the daily schedule Operating the daily scheduleField Setting Mode Setting the Field Setting Value of wired remote controllerField Setting ValueFSV Table Field Setting ValueDHW BUH/BSH Priority Remote Controller Setting Range Code Space CoolingSpace Heating DHW HeatingWater Law & Room Thermostat Code Water Law for HeatingWater Law for Cooling External Room Thermostat Field OptionDHW Heating Code DHW Application Heat Pump Variables for Controlling DHW Tank#3033 Booster Heater Variables for Controlling DHW Tank Disinfection FunctionSpace Heating Code Heat Pump Variables for Space HeatingBackup Heater Variables for Space Heating External Backup Boiler for Space Heating Field OptionOuting Mode Hot Key of Wired Remote Controller Others CodeEconomic DHW Heating TDMTime-Division Multi VariablesTemperature Table DIP Switch SettingAppendix Available operation rangeMaintenance activities Maintaining the UnitTroubleshooting Tips ThermistorCommunication TroubleshootingE654 E911 Water pump & Flow S/WE912 Disposal Requirements Memo 50Memo Memo