Samsung NH200WHXEA, NH200WHXES, NH160PHXEA Water Law & Room Thermostat Code, Water Law for Heating

Page 34

Operating advanced function

FIELD SETTING MODE

Water Law & Room Thermostat : Code 20✴✴

 

Ts

 

 

 

Ts : Target Temp.

#2021/2031

 

 

Cooling WL

 

Ta : Ambient Temp.

 

 

 

 

#2022/2032

 

 

 

 

 

 

 

 

 

#2061/2071

 

 

 

 

 

 

 

 

 

Shift Value

#2062/2072

 

 

 

 

Heating WL

 

 

����������

Floor

FCU

 

 

 

 

 

 

 

 

 

 

#2011

#2012

#2051

#2052

Ta

 

 

 

 

 

 

Field Setting Value

Main Menu &

Sub Menu Function

Description

Sub

Default

Min

Max

Step

Unit

Code

Code

 

 

 

 

 

 

 

Water Law

Outdoor Temp for Water Law

Point

✴✴11

-10

-20

5

1

˚C

Code 20✴✴

(Heating)

Point

✴✴12

15

10

20

1

˚C

Water Out Temp for WL1 Heating

Point

✴✴21

40

40

55

1

˚C

 

 

(WL1-Floor)

Point

✴✴22

25

17

37

1

˚C

 

Water Out Temp for WL2 Heating

Point

✴✴31

50

40

55

1

˚C

 

(WL2-Fan Coil Unit)

Point

✴✴32

35

17

37

1

˚C

 

Heating Water Law for Auto Mode

WL Type

✴✴41

1(WL1)

1

2(WL2)

-

-

 

Outdoor Temp for Water Law

Point

✴✴51

30

25

35

1

˚C

 

(Cooling)

Point

✴✴52

40

35

45

1

˚C

 

Water Out Temp for WL1 Cooling

Point

✴✴61

25

18

25

1

˚C

 

(WL1-Floor)

Point

✴✴62

18

5

18

1

˚C

 

Water Out Temp for WL2 Cooling

Point

✴✴71

18

18

25

1

˚C

 

(WL2-Fan Coil Unit)

Point

✴✴72

5

5

18

1

˚C

 

Cooling Water Law for Auto Mode

WL Type

✴✴81

1(WL1)

1

2(WL2)

-

-

 

External Thermostat Application

#1(Floor)

✴✴91

0(No)

0

1(Yes)

-

-

 

#2(FCU)

✴✴92

0(No)

0

1(Yes)

-

-

 

 

Water Law for Heating

Outdoor air temperature range : Lower limit (#2011, Default -10˚C, Range : -20 ~ 5˚C), Upper limit (#2012, Default 15˚C, Range : 10 ~ 20˚C)

-With this default settings, the water outlet temperature by heating water law can be changed within the outdoor temperature range of -10 ~ 15˚C.

Water out temperature range for floor/FCU applications respectively :

Upper limit (#2021/2031, Default 40/50˚C, Range : 40 ~ 55˚C), Lower limit (#2022/2032,

Default 25/35˚C, Range : 17 ~ 37˚C)

-With this default settings, the water outlet temperature by heating water law can be changed within the range of 25/35 ~ 40/50˚C.

Type of water law for according to heating devices(floor/FCU) : #2041(Default “1”(WL1 for floor)), “2”(WL2 for FCU or radiator)

The #2 DIP switch in the wired remote controller should be set to “OFF”(Default) to control the water outlet temperature.

The operation mode of the wired remote controller should be set to “AUTO”() to use the weather dependent water law scheme.

34_ Operating advanced function

Image 34
Contents Air to Water Heat Pump Hydro Unit F I P D DB98-32035A2Integrated Heating & Cooling System at a Lower Cost High Performance at Low TemperatureQuick Heating by TDM Technology Running Costs-Reduction of Up to 33.3%Contents Safety precautions Important safety symbols and precautionsFor Using Safety information This may result in harm to humans, animals or plantsOverview Control PanelChecking the function of buttons and indicators Space Operation ModeDHW Operation Mode DHWTemperature Adjustment Display FunctionHOT KEY Schedule Status Indicator Mode Status Display FunctionOptional Function Indicator A2AAvailable Mode Operating basic functionSpace Heating Operation Space Cooling Operation Water LAW Domestic Water Heating Operation To cancel the DHW mode Urgent DHW ModeOperating hot key function Outing Mode To cancel the outing modeSetting the Time Operating advanced functionSetting the 7-DAYWEEKLY Schedule Set, Cancel/Delete buttonViewing the 7-dayWeekly Schedule On / Off Display Deleting the 7-dayWeekly schedule Setting the Daily Schedule Viewing the Daily Schedule On / Off Display Deleting the daily schedule Operating the daily scheduleField Setting Mode Setting the Field Setting Value of wired remote controllerField Setting ValueFSV Table Field Setting ValueDHW BUH/BSH Priority Space Heating Remote Controller Setting Range CodeSpace Cooling DHW HeatingWater Law & Room Thermostat Code Water Law for HeatingWater Law for Cooling External Room Thermostat Field OptionDHW Heating Code DHW Application Heat Pump Variables for Controlling DHW Tank#3033 Booster Heater Variables for Controlling DHW Tank Disinfection FunctionSpace Heating Code Heat Pump Variables for Space HeatingBackup Heater Variables for Space Heating External Backup Boiler for Space Heating Field OptionEconomic DHW Heating Outing Mode Hot Key of Wired Remote ControllerOthers Code TDMTime-Division Multi VariablesAppendix Temperature TableDIP Switch Setting Available operation rangeMaintenance activities Maintaining the UnitTroubleshooting Tips ThermistorCommunication TroubleshootingE654 E911 Water pump & Flow S/WE912 Disposal Requirements Memo 50Memo Memo