Samsung NH300WHXES, NH200WHXES, NH160PHXEA, NH080PHXEA, NH300WHXEA user manual Space Cooling Operation

Page 17

SPACE COOLING OPERATION

In this mode, cooling will be activated as required by the water temperature set point.

The set point can be set manually

or set weather dependant

1. Press Power(Space mode) button to turn on the heat pump unit.

The heat pump will be turned on in the mode you select.

• Space water cooling devices: Radiator or Fan coil unit (field supply)

• Heating and cooling mode can not be selected at the same time.

• Space cooling operation is not possible if the installation is a heating only installation.

The heat pump has a built-in protection mechanism CAUTION to prevent the unit from being damaged when it is

started immediately after being plugged in or stopped, the heat pump will start up after 3 minutes.

2.Press the Mode(Space mode) button twice to select the space cooling mode. The heat pump will run on cooling mode.

3.Press Upor Downbutton to set the desired temperature. The temperature can be set between 5ºC to 25ºC.

The temperature is adjusted by 0.5ºC.

ENGLISH

Operating basic function _17

Image 17
Contents F I P D DB98-32035A2 Air to Water Heat Pump Hydro UnitQuick Heating by TDM Technology High Performance at Low TemperatureIntegrated Heating & Cooling System at a Lower Cost Running Costs-Reduction of Up to 33.3%Contents Important safety symbols and precautions Safety precautionsFor Using This may result in harm to humans, animals or plants Safety informationControl Panel OverviewSpace Operation Mode Checking the function of buttons and indicatorsDHW DHW Operation ModeDisplay Function Temperature AdjustmentHOT KEY Schedule Mode Status Display Function Status IndicatorA2A Optional Function IndicatorOperating basic function Available ModeSpace Heating Operation Space Cooling Operation Water LAW Domestic Water Heating Operation Operating hot key function Urgent DHW ModeTo cancel the DHW mode To cancel the outing mode Outing ModeOperating advanced function Setting the TimeSet, Cancel/Delete button Setting the 7-DAYWEEKLY ScheduleViewing the 7-dayWeekly Schedule On / Off Display Deleting the 7-dayWeekly schedule Setting the Daily Schedule Viewing the Daily Schedule On / Off Display Operating the daily schedule Deleting the daily scheduleSetting the Field Setting Value of wired remote controller Field Setting ModeField Setting Value Field Setting ValueFSV TableDHW BUH/BSH Priority Space Cooling Remote Controller Setting Range CodeSpace Heating DHW HeatingWater Law for Heating Water Law & Room Thermostat CodeExternal Room Thermostat Field Option Water Law for CoolingDHW Heating Code Heat Pump Variables for Controlling DHW Tank DHW Application#3033 Disinfection Function Booster Heater Variables for Controlling DHW TankHeat Pump Variables for Space Heating Space Heating CodeExternal Backup Boiler for Space Heating Field Option Backup Heater Variables for Space HeatingOthers Code Outing Mode Hot Key of Wired Remote ControllerEconomic DHW Heating TDMTime-Division Multi VariablesDIP Switch Setting Temperature TableAppendix Available operation rangeMaintaining the Unit Maintenance activitiesThermistor Troubleshooting TipsE654 TroubleshootingCommunication E912 Water pump & Flow S/WE911 Disposal Requirements Memo 50Memo Memo