Panasonic SC-HTB500 For Saudi Arabia and Kuwait, Before use, How to replace the fuse

Page 22

Caution for AC Mains Lead

(For Saudi Arabia and Kuwait)

For your safety, please read the following text carefully.

This appliance is supplied with a moulded three pin mains plug for your safety and convenience.

A 5-ampere fuse is fitted in this plug.

Should the fuse need to be replaced please ensure that the replacement fuse has a rating of 5-ampere and that it is approved by ASTA or BSI to BS1362.

Check for the ASTA mark Ï or the BSI mark Ì on the body of the fuse.

WARNING: DO NOT CONNECT EITHER WIRE TO THE EARTH TERMINAL WHICH IS MARKED WITH THE LETTER E, BY THE EARTH SYMBOL

ÓOR COLOURED GREEN OR GREEN/ YELLOW.

THIS PLUG IS NOT WATERPROOF—KEEP DRY.

Before use

Remove the connector cover.

If the plug contains a removable fuse cover you must ensure that it is refitted when the fuse is replaced.

If you lose the fuse cover the plug must not be used until a replacement cover is obtained.

A replacement fuse cover can be purchased from your local dealer.

How to replace the fuse

The location of the fuse differ according to the type of AC mains plug (figures A and B). Confirm the AC mains plug fitted and follow the instructions below.

Illustrations may differ from actual AC mains plug.

1. Open the fuse cover with a screwdriver.

CAUTION!

IF THE FITTED MOULDED PLUG IS UNSUITABLE FOR THE SOCKET OUTLET IN YOUR HOME THEN THE FUSE SHOULD BE REMOVED AND THE PLUG CUT OFF AND DISPOSED OF SAFELY.

THERE IS A DANGER OF SEVERE ELECTRICAL SHOCK IF THE CUT OFF PLUG IS INSERTED INTO ANY 13-AMPERE SOCKET.

If a new plug is to be fitted please observe the wiring code as stated below.

If in any doubt please consult a qualified electrician.

IMPORTANT

The wires in this mains lead are coloured in accordance with the following code:

Blue: Neutral, Brown: Live.

As these colours may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:

The wire which is coloured Blue must be connected to the terminal which is marked with the letter N or coloured Black or Blue.

The wire which is coloured Brown must be connected to the terminal which is marked with the letter L or coloured Brown or Red.

Figure A

Figure B

Fuse cover

2. Replace the fuse and close or attach the fuse cover.

Figure A

 

Figure B

 

Fuse

Fuse

 

(5 ampere)

 

(5 ampere)

 

 

22

Image 22
Contents Included Installation Instructions Model No. SC-HTB500Others Continental Europe, Australia and New ZealandFor details, please refer to Safety precautions LicensesTable of Contents Unit care AccessoriesClean this unit with a soft, dry cloth To dispose or transfer this unitControl reference guide Standby/on switch Í/IRemote control operation range Distance This unit and active subwoofer FrontRemote control To replace a button-type batteryThis unit PlacementOn the wall A rack § 1, 2 Active subwoofer If the TV’s remote control sensor is Blocked by this unitIf it persists, move this unit further away from the TV Assembling the unit To prevent the unit from fallingBasic connection with an ARC compatible TV ConnectionsConnection to a TV Hdmi cable not supplied≥Connect this unit to the TV Blu-ray Disc Player Connection from an Hdmi compatible deviceDigital transmitter connection Do not insert or remove while this unit is onSet the voltage Active subwoofer wireless connectionAC mains lead connection Press C I, B Í on the active subwooferTo adjust the volume/ subwoofer level Using this unitAudio source indicator Audio format indicatorVarious audio effects Audio effectsChanging the audio effects Linked operations with the TV Automatic input switchingWhat is Viera Link Hdavi Control? Speaker SelectionSpecifications Audio information TroubleshootingPower General operationSound Active subwooferViera Link Remote control codeChanging this unit’s settings TV AudioTV’s remote control signal sensor Using the IR BlasterPlacement example For Saudi Arabia and Kuwait How to replace the fuseBefore use For installation, use the special-purpose constituent parts Do not install at a location that cannot bear the loadDo not install at a location other than a vertical wall Do not modify the wall mount bracketsPrecautions for wall mount bracket installation Requests regarding handlingComponents Installation procedureNever use any other method than specified to install Attaching the wall mount bracketsConnections PlacementChecking the strength of the installation location Complete all the necessary connections to this unitAttaching this unit to a wall Attach the lock pins into the wall mount bracketThread a cord not supplied through the wall mount bracket Attach the cord to a wall with a screw not supplied Push the lock pins fully into placeMount the unit securely onto the screws Move this unit so that the screw is in this positionInstallation Instructions Digital Transmitter RFAX1032, Active Subwoofer SB-WA500 Norsk Samsvarserklæring DoC Page Ideas for life Suomi Varoitus For business users in the European Union Panasonic Corporation