Appendix C:
Power
Direct from PoE (Power over Ethernet) Switch
Note: PoE has not been UL verified.
Optional: External (24 VDC, 1 A) Power Supply
Note: Power Supply must be UL 294 listed with a power limited output rating of 9.5 to 24 VDC.
Communication
Ethernet
Cable
Reader Ports
There are 2 reader ports on an
Reader Power
Note: Shared with Output 1 and Output 2. Refer to “Outputs” below.
Reader Types
Note: Recommended standard Wiegand readers are the HID ProxPoint Plu 6005 series, HID ProxPro 5355 series, or XceedID model XF2100.
Note: Smart Card readers are not yet supported in the
Inputs
There are 4 programmable inputs on an
Note: The tamper sensor can be programmed within the Alarm Services of the Supervisor Plus software, and must be enabled to meet UL requirements. Refer to the
Outputs
There are 3 programmable outputs and a
Outputs 1 & 2
Note: The eIDC provides 750 mA of continuous power:
•The maximum total of all output power from the eIDC is 750 mA.
•The maximum output of either reader is 250 mA.
•The maximum output from the combined open collectors is whichever of the following is less: 450 mA or 750 mA less the sum of the readers.
Output 3
Certifications
CE, FCC, ROHS, UL 294