Chapter 4: Wiring Connections And Configurations
Single Door Door Configuration With S-EIDC-U
Optional
Power Connector
To Ethernet Hub
Ethernet
ConnectionBuilt-in
Infrared Tamper
Note: Maglock is required to have additional external UL listed power supply.
Door Strike
Door Contact
Card Reader
or Keypad
To Reader LED Output
Output 1
Output 2
Input 1
Common
Input 2
Card Reader
IN
Power
Output 1
Output 3 - NC
Common
Output 3 - NO
Input 3
Common
Input 4
Card Reader
OUT
Power
Output 2
Lock
Card Reader
or Keypad
Optional External
Power Supply
24 vDC, 1 Amp
24V DC IN
Warning Buzzer
Reader LED Output
Reader Buzzer Output
S-EIDC-U
CAT 5/6
To Ethernet Hub
(PoE Switch)
Note: The
Note: To meet UL requirements, listed panic hardware must be used to allow emergency exit from the protected area.
28 |