Intelli-M Hardware Overview

Chapter 1: Intelli-M® Hardware Overview

Intelli-M Hardware Overview

This manual provides reference, installation, and technical specifications for the hardware products that are used with the Intelli-M system. Technical specifications for each product are also provided. The following Intelli-M hardware products are discussed in this manual, and are currently available:

S-EIDC-U (ethernet Integrated Door Controller) in Chapter 2

S-PCON-U (Power Connector) in Chapter 3

The Intelli-M system uses a door controller called the S-EIDC-U (ethernet Integrated Door Controller). The S-EIDC-U controller is state of the art, being only a fraction of the size of more traditional access control hardware but fully capable of providing maximum security. The controller will fit into any standard double gang box, and simply click into a mounting plate for easy installation. As shown in the “S-EIDC-U Sample Configuration” illustration below, the S- EIDC-U receives both power and communication from the ethernet by way of a single CAT 5 or 6 cable connected to a PoE (Power over Ethernet) enabled switch.

 

S-PCON-U

Note: The S-PCON-U is an optional power

CAT 5/6

(Power Connector)

source used to enhance power to the S-EIDC-U.

 

To PoE Switch

 

 

Note: The S-EIDC-U device and its optional UL listed Power Supply must be installed within the protected area (locked area) of the access facility to meet UL requirements.

Note: To meet UL requirements, listed panic hardware must be used to allow emergency exit from the protected area.

S-EIDC-US-EIDC-U

Built-in

Warning Buzzer

Sample S-EIDC-U Configuration

A module called the S-PCON-U (Power Connector) can also be used to route the power and communication data from a CAT 5 or 6 cable to the S-EIDC-U. The S-EIDC-U device is capable of peer-to-peer communication, industry-standard IP protocol support (DHCP), and AES 128-bit encrypted communications.

Note: Peer-to-peer communication, IP protocol support (DHCP), and AES 128-bit encrypted communications have not been UL verified for the S-EIDC-U and S-PCON-U.

8

Intelli-M Hardware Installation And Reference Guide

Image 8
Contents C3653M-A11/08 Hardware Installation And ReferencePelco, Inc. Worldwide Headquarters Preface TrademarksTable of Contents Recessed Mounting Box FCC Declaration Of Conformity S-EIDC-U, S-PCON-U UL Compliance S-EIDC-U, S-PCON-UOfficial Notices Official Notices Chapter 1 Intelli-M Hardware Overview Contents Intelli-MHardware Overview Using This ManualIntelli-MHardware Overview S-EIDC-UUsing This Manual Chapter 1 Intelli-MHardware OverviewChapter 1 Intelli-MHardware Overview ethernet Integrated Door Controller Contents Chapter 2 S-EIDC-UTechnical Features S-EIDC-UOverviewS-EIDC-U Wiring S-EIDC-UDoor ComponentsS-EIDC-UDoor Component Wiring Step 2: Wire the status, shunt, and exit inputs Step 3 Wire the readersKeep in mind the following points Keep in mind the following pointsPowering Up An S-EIDC-U Four Power OptionsDetermining The Network IP Address Type Setting A Static IP Address Within The S-EIDC-U Setting A DHCP IP Address Within The S-EIDC-U Setting An S-EIDC-UFor DHCP AddressingQuick Mount Assembly Breakdown Resetting An S-EIDC-UQuick Mount Assembly Page S-PCON-UOverview Chapter 3 S-PCON-U Power Connector ContentsWiring And Powering Up S-PCON-U Technical Features S-PCON-UOverviewWiring And Powering Up S-PCON-U S-PCON-UWiring and Powering up DiagramChapter 3 S-PCON-UPower Connector Chapter 4 Wiring Connections And Configurations ContentsSample S-EIDC-UGlobal Configuration S-EIDC-UWiring TerminalsS-EIDC-U Sample S-EIDC-UGlobal ConfigurationChapter 4 Wiring Connections And Configurations S-EIDC-UWiring Terminals Single Door Door Configuration With S-EIDC-U S-EIDC-UAppendix A eFamily Update Utility ContentsInstalling The eFamily Update Utility eFamily Update ProcedureInstalling The eFamily Update Utility 2.Launch double click the “setup.exe” fileSupervisor Plus Users Web Interface Users6.Click the “Close” button eFamily Update Procedure Before Updating Your eFamily DeviceFigure A-7 Connection Information Screen Figure A-6 Choice To Backup ScreenFigure A-5 Connection Information Screen Page Figure A-11 Connection Information Request Screen Figure A-12 Update In Process Screen Figure A-13 Update Complete ScreenErrors That Occur During Update Figure A-14 Example Error MessagePage Appendix B Demo Kit Wiring DefaultsInput Configuration Output ConfigurationAlarm Service Configuration Controller ConfigurationAccess Service Configuration S-EIDC-UTechnical Specifications DimensionsQuick Mount Assembly Kit Enclosure Ethernet Integrated Door ControllerPower CommunicationReader Ports InputsS-PCON-UTechnical Specifications Power Controller OperationalDimensions Power Connector Module S-PCON-UPower In DC Power --24 VDC, 1APower Out DC Power --22.9 to 24 VDC, 1AMiscellaneous Computer Hardware Specifications Performance Communications Server RequirementsMinimum Server Requirements Performance Badging / Workstation RequirementsMinimum Badging / Workstation Requirements Digital CameraUSB Camera WebCam Signature Capture