Slant/Fin V-180, V-33 operating instructions Left End View, Front View, Right End View, Victory

Page 2
VICTORY

2

VICTORY

Figure 1. Left End View

Figure 2. Front View

Figure 3. Right End View

NOTE: Height Dimension increases to 30-3/16" and depth dimension increases to 22-1/4" when combustible floor kit is used.

 

 

 

 

 

Dimensions (inches)

 

Approx.

Size of Gas Line

 

 

 

 

 

 

 

 

 

Total Wt.

Connection to Boiler

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C = Vent Dia.

 

 

 

 

 

 

 

 

 

Full Of

(inches)

 

 

 

 

 

 

 

Boiler

No. of

A

B

 

Pressure Horizontal

Natural draft chimney

D

Water

 

 

Natural

Propane

Model

Sections

 

or Vertical Venting

or type “B” venting

(lb.)

V-33

2

818"

1458"

3"

912"

190

12"

12"

V-60

3

1118"

1758"

3"

1212"

250

12"

12"

V-90

4

1418"

2058"

3"

5"

 

1412"

310

12"

12"

V-120

5

1718"

2358"

3"

5"

 

1712"

365

12"

12"

V-150

6

2018"

2658"

3"

5"

 

2012"

425

12"

12"

V-180

7

2318"

2958"

3"

5"

 

2312"

485

12"

12"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Orifice Sizes for High Altitudes

 

 

 

 

 

 

 

 

 

 

 

Boiler

Gas

Orifice

 

Includes 4% Reduction for Each 1000 Feet

 

 

Size for

 

 

 

Elevation — Feet

 

 

 

 

Model

Type

Sea Level

2000

3000

4000

5000

6000

7000

8000

9000 10000

 

V-33

Natural

#48

49

50

50

50

51

51

52

52

52

 

V-33

Propane

#56

56

56

57

57

57

58

59

59

60

 

V-60 thru V-180

Natural

#50

51

51

51

52

52

52

52

53

53

 

V-60 thru V-180

Propane

#57

58

59

59

60

60

61

62

63

63

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Orifice sizes indicated for sea level above are factory installed in boiler unless otherwise specified by the local authority. Orifice table is based on a higher heating value between 1000 Btuh and 1009 Btuh for Natural Gas (see III, page 13, if local higher heating value exceeds these numbers). See III, page 13, for burner input adjustment.

Base Assembly

 

Victory Boiler

Burners

Pilot

Burner

Access Door

Gas Valve

Gas Manifold Figure 1. Left End View

Image 2
Contents Victory HOT WATER MODELS V-33THROUGHFigure 3. Right End View Figure 1. Left End ViewFigure 2. Front View VICTORYNATURAL GAS FIRED BOILER LOCATION INSTALLATION REQUIREMENTSVICTORY BOILER FOUNDATIONReference Table No Figure 4. Vent Sealing Instructions VICTORYRequirements VICTORYModel/Vent Size NATURAL DRAFT CHIMNEYALL ITEMS SHOWN BELOW ARE REQUIRED All vent connector joints must be LIQUID tightFigure 6a Horizontal Venting 3 IN. All Victory Models VICTORY Horizontal Venting 3 IN. All Victory ModelsVertical Venting 3 IN. All Victory Models VICTORYBOILER ROOM AIR SUPPLY AND VENTILATION ELECTRICAL CONTROLS AND WIRINGVICTORY OPERATING INSTRUCTIONS, BASIC SAFETY INFORMATIONVICTORY I. FILLING AND VENTING WATER SYSTEMSIII. BURNER ADJUSTMENT VICTORYCARE AND MAINTENANCE VICTORYburners as described on page APPENDIX B Vent System Location and Condensation VICTORYAPPENDIX A Drain RequirementsWiring Diagrams Sequence of OperationsCOMBINATION CONTROLS WITH T TV Z Pump Zoning system using R845 RelayOne R-845Aneeded for each circulator TERMINALSGENERAL TROUBLESHOOTING GUIDE FOR SERVICEPEOPLE PIPING A HEATING - COOLING SYSTEM TO A WATER IF REPLACEMENT PARTS ARE NEEDEDVICTORY BOILER AND CHILLER