Slant/Fin VSPH-60, VSPH-180 operating instructions Ratings and Dimensions, Victory Vsph Models

Page 2

2

VICTORY VSPH Models

RATINGS AND DIMENSIONS

NOTE: Height dimensions increase by 112" and depth increases to 2812" when combustible floor kit is used.

 

Figure 1. Dimensions data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Boiler

Input

No. of

 

 

 

 

Model

Btuh

Sections

A

B

 

 

 

 

 

VSPH-60

60,000

3

1118"

1738"

 

 

 

 

 

 

 

VSPH-90

90,000

4

1418"

2038"

 

 

 

 

 

 

 

VSPH-120

120,000

5

1718"

2338"

 

VSPH-150

150,000

6

2018"

2638"

 

 

 

 

 

 

 

VSPH-180

180,000

7

2318"

2938"

 

 

 

 

 

 

 

Gas Orifice Size

 

 

 

 

 

 

 

 

 

 

 

 

Victory VSPH boiler

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Orifice Sizes for High Altitudes

 

 

 

 

 

 

Orifice

 

 

Includes 4% Reduction for Each 1000 Feet

 

 

 

 

Gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Elevation — Feet

 

 

 

 

 

 

Size for

 

 

 

 

 

 

 

 

 

 

Type

 

 

 

 

 

 

 

 

 

 

Sea Level

2000

3000

4000

5000

6000

7000

8000

9000

10000

 

 

 

 

 

 

 

Natural

#49

50

50

50

51

51

51

52

52

52

 

 

 

Propane

#57

58

59

59

60

60

61

62

63

63

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Orifice sizes indicated for sea level above are factory installed in boiler unless otherwise specified by the local authority. Orifice table is based on a higher heating value between 1000 Btuh and 1010 Btuh for Natural Gas (See page 20, if local higher heat- ing value exceeds these numbers). See page 20, for burner input adjustment.

Image 2
Contents Table of Contents Victory VsphBoiler Input No. Model Btuh Sections Ratings and DimensionsVictory Vsph Models Base Assembly Location and Identification of PartsLiquefied Petroleum L.P. Propane GAS-FIRED Boiler Location SafetyNatural GAS-FIRED Boiler Location Boiler FoundationVenting Application NON-DIRECT Vent InstallationDirect Vent Installation Boiler Room AIR Supply and VentilationAIR Intake Pipe Material Flue and AIR Intake Restrictions000 Ft 000 7,500 Ft 500 10,000 Ft Sidewall Venting NON-DIRECT Vent Venting InstallationVENT/AIR Intake Termination Installation Vent Termination Location and ClearancesVictory Vsph Models NON Direct VENT, Sidewall Venting Non-direct vent, side wall ventingAL 29-4C is a Registered Trademark of Allegheny Ludlum Corp Victory Vsph Models Victory Vsph Models Direct VENT, Sidewall Venting Direct Vent Venting and AIR Intake Through a Roof Vent/Air Intake TerminationVictory Vsph Models Direct VENT, Venting and AIR Intake Through a RoofVenting and AIR Intake System Regular Inspection Electrical WiringPower Supply GAS PipingSchematic wiring diagram Multizoning of Vsph Boiler Water Piping Thermostat ConnectionsMulti Zoning Operating Instructions Safety Information Vsph Boiler Sequence of Operation Limit Press Switch Flame LED Normal Operation Status of Indicator Lights LED’SDescription of Operation Power TSTAT/CIRC LED Integrated Boiler ControlIndication Remedy Diagnostic Flash CodesLED’s Flashing Cleaning Care and MaintenanceGeneral Maintenance II. Inspection During Heating SeasonGeneral Troubleshooting Guide For Service Personnel Burners Fail to OPERATE- no Heat CauseNot Enough Heat Cause Burner will not Shut OFF CauseFumes and GAS Odors Cause Remedy If Replacement Parts are NeededBurner Short Cycles Cause Remedy SLANT/FIN CORPORATION, Greenvale, N.Y Phone 516

VSPH-180, VSPH-60 specifications

Slant/Fin is a renowned name in the heating industry, renowned for its innovation, quality, and efficiency. Among its popular offerings are the VSPH-180 and VSPH-60, two highly efficient gas-fired residential boilers designed to provide reliable heating for homes.

The VSPH-180 is a high-efficiency residential boiler that delivers exceptional heating performance while being mindful of energy consumption. It operates at an impressive AFUE (Annual Fuel Utilization Efficiency) rating of up to 95%, meaning it uses 95% of the fuel burned for heating, resulting in lower energy bills and reduced environmental impact. The VSPH-180 features a durable stainless steel heat exchanger that not only contributes to its efficiency but also prolongs the boiler's lifespan.

On the other hand, the VSPH-60 is a slightly smaller but equally efficient model that is perfect for apartments or smaller homes. It also boasts a remarkable AFUE rating of up to 95%, ensuring cost-effective heating solutions. The compact design of the VSPH-60 allows for easy installation in various locations, making it a versatile choice for homeowners seeking space-saving options without compromising on performance.

One of the standout technologies in both models is the modulating gas valve, which adjusts the burner’s output to match the heating demand. This feature enhances energy efficiency by preventing the boiler from working harder than necessary, ensuring consistent temperatures and reducing wear on the unit. Furthermore, both models are equipped with a built-in electronic ignition system, eliminating the need for a pilot light and adding convenience for homeowners.

The VSPH series is designed with maintenance ease in mind. It features a user-friendly control panel that provides easy access to critical information, allowing for straightforward diagnostics and service. Regular maintenance can be performed with minimal disruption, enabling owners to keep their systems running optimally throughout the heating season.

In conclusion, the Slant/Fin VSPH-180 and VSPH-60 represent excellence in residential heating technology. With high AFUE ratings, durable construction, and advanced features, both boilers provide efficient and reliable heating solutions, ensuring comfort and energy savings for homeowners.