Slant/Fin VSPH-60, VSPH-180 operating instructions Safety Information

Page 20

20

VICTORY VSPH Models

II.Initial Start

Safe lighting and other performance criteria were met when testing various gas manifold and control assemblies used on the Victory VSP Series Boilers under the ANSI Z21.13- latest edition.

Instructions

Follow the lighting instructions in this manual. These instructions are also attached to the boiler.

SAFETY INFORMATION

For Your Safety Read Before Operating

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance is equipped with an ignition device which automatically lights the pilot. DO NOT try to light the pilot by hand.

B.BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

DO NOT try to light any appliance.

DO NOT touch any electric switch: DO NOT use any phone in your building.

Immediately call you gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire depart- ment.

C.Use only your hand to turn the gas control knob. Never use tools. If the knob will not turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do Not use this appliance if any part has been under

water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

OPERATING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Set the thermostat to lowest setting.

3.Turn off all electric power to the appliance.

4.This appliance is equipped with an ignition device which automatically lights the pilot. DO NOT try to light the pilot by hand.

5.Remove jacket front panel

6.Turn gas control knob clockwise to “OFF”. DO NOT force.

7.Wait five (5) minutes (longer for propane) to clear out any gas, then smell for gas, including near the floor. If you then smell gas, STOP! Follow “B” in the safety information above on this page. If you don’t smell gas, go to next step.

8.Turn as control knob counterclockwise to “ON”.

9.Replace jacket front panel.

10.Turn on all electric power to the appliance.

11.Set thermostat to desired setting.

12.If the appliance will not operate, follow the instructions “To Turn Off Gas to Appliance” and call your service technician or gas supplier.

To Turn Off Gas to Appliance

1.Set thermostat to lowest setting.

2.Turn off all electric power to the appliance if service is to be performed.

3.Remove jacket front panel.

4.Turn gas control knob clockwise till knob stops, then continue to “OFF”. Do not force.

5.Replace jacket front panel.

Gas Valve VR8204 or VR8304

HONEYWELL

 

GAS

OUTLET

ON

INLET

 

0FF

 

GAS CONTROLKNOB

 

SHOW N IN "OFF"

 

POSITIONN

 

 

Figure 19.

Removing Jacket Front Panel

1.Turn black screws 14 turn to open position.

2.Remove front panel.

To replace the panel, reverse procedure.

Gas Input Rate Adjustment

1.Consult gas supplier for higher heating value* of gas (Btu/cu. ft.)

2.Set thermostat high enough so that boiler will remain on

3.Measure manifold pressure.

Correct manifold pressure for gas used is printed on boiler rating plate. NOTE: Gas pressure may be adjusted by turning pressure regulator screw on combination gas valve (turn clockwise to increase pressure, counterclockwise to decrease pressure).

* ”Higher Heating” value of gas is commonly known as “heating value”.

Image 20
Contents Table of Contents Victory VsphBoiler Input No. Model Btuh Sections Ratings and DimensionsVictory Vsph Models Base Assembly Location and Identification of PartsSafety Natural GAS-FIRED Boiler LocationLiquefied Petroleum L.P. Propane GAS-FIRED Boiler Location Boiler FoundationNON-DIRECT Vent Installation Direct Vent InstallationVenting Application Boiler Room AIR Supply and VentilationAIR Intake Pipe Material Flue and AIR Intake Restrictions000 Ft 000 7,500 Ft 500 10,000 Ft Venting Installation VENT/AIR Intake Termination InstallationSidewall Venting NON-DIRECT Vent Vent Termination Location and ClearancesVictory Vsph Models NON Direct VENT, Sidewall Venting Non-direct vent, side wall ventingAL 29-4C is a Registered Trademark of Allegheny Ludlum Corp Victory Vsph Models Victory Vsph Models Direct VENT, Sidewall Venting Direct Vent Venting and AIR Intake Through a Roof Vent/Air Intake TerminationVictory Vsph Models Direct VENT, Venting and AIR Intake Through a RoofElectrical Wiring Power SupplyVenting and AIR Intake System Regular Inspection GAS PipingSchematic wiring diagram Multizoning of Vsph Boiler Water Piping Thermostat ConnectionsMulti Zoning Operating Instructions Safety Information Vsph Boiler Sequence of Operation Normal Operation Status of Indicator Lights LED’S Description of Operation Power TSTAT/CIRC LEDLimit Press Switch Flame LED Integrated Boiler ControlIndication Remedy Diagnostic Flash CodesLED’s Flashing Care and Maintenance General MaintenanceCleaning II. Inspection During Heating SeasonGeneral Troubleshooting Guide For Service Personnel Burners Fail to OPERATE- no Heat CauseNot Enough Heat Cause Burner will not Shut OFF CauseFumes and GAS Odors Cause Remedy If Replacement Parts are NeededBurner Short Cycles Cause Remedy SLANT/FIN CORPORATION, Greenvale, N.Y Phone 516

VSPH-180, VSPH-60 specifications

Slant/Fin is a renowned name in the heating industry, renowned for its innovation, quality, and efficiency. Among its popular offerings are the VSPH-180 and VSPH-60, two highly efficient gas-fired residential boilers designed to provide reliable heating for homes.

The VSPH-180 is a high-efficiency residential boiler that delivers exceptional heating performance while being mindful of energy consumption. It operates at an impressive AFUE (Annual Fuel Utilization Efficiency) rating of up to 95%, meaning it uses 95% of the fuel burned for heating, resulting in lower energy bills and reduced environmental impact. The VSPH-180 features a durable stainless steel heat exchanger that not only contributes to its efficiency but also prolongs the boiler's lifespan.

On the other hand, the VSPH-60 is a slightly smaller but equally efficient model that is perfect for apartments or smaller homes. It also boasts a remarkable AFUE rating of up to 95%, ensuring cost-effective heating solutions. The compact design of the VSPH-60 allows for easy installation in various locations, making it a versatile choice for homeowners seeking space-saving options without compromising on performance.

One of the standout technologies in both models is the modulating gas valve, which adjusts the burner’s output to match the heating demand. This feature enhances energy efficiency by preventing the boiler from working harder than necessary, ensuring consistent temperatures and reducing wear on the unit. Furthermore, both models are equipped with a built-in electronic ignition system, eliminating the need for a pilot light and adding convenience for homeowners.

The VSPH series is designed with maintenance ease in mind. It features a user-friendly control panel that provides easy access to critical information, allowing for straightforward diagnostics and service. Regular maintenance can be performed with minimal disruption, enabling owners to keep their systems running optimally throughout the heating season.

In conclusion, the Slant/Fin VSPH-180 and VSPH-60 represent excellence in residential heating technology. With high AFUE ratings, durable construction, and advanced features, both boilers provide efficient and reliable heating solutions, ensuring comfort and energy savings for homeowners.