10.From inside, install inside termination plate using 4 screws. Make sure the 4" collar on the plate, penetrate- ed into the galvanized pipe.

11.Assemble and seal straight screened termination to the slip joint connector.

12.From outside of the building, insert vent pipe (slip joint connector and termination assembly) through the 3" holes of the outside and inside termination plate.

13.From outside of the building seal outside termination plate to building.

14.From inside, proceed with air intake and vent pipe installation. Follow vent manufacturer’s instructions and restrictions mentioned on page 6 of this manual. DO NOT exceed the maximum allowed equivalent lengths given in tables on page 7.

When joining various components of the vent system and air intake piping, proper sealant must be used (see page 6). Install horizontal vent pipe with seams on the top. Connect and seal air intake piping to air intake collar of the boiler. Adjust the air pipe support to hold air intake pipe securely (see Figure 2).

B.DIRECT VENT - VENTING AND AIR INTAKE THROUGH A ROOF

Figure 12 shows typical vertical venting. The vent pipe must pass through the ceiling, floor and the roof vertically through a 7" minimum diameter cutout. A fire stop is required for each ceiling and floor penetration. For roof passage an appropriate UL listed roof flashing must be used.

The vertical vent piping must terminate with a screened straight termination.

The air intake terminal should be a screened 180˚ elbow fac- ing down. The air intake opening must be at least 1 foot below the vent opening.

Follow vent manufacturer’s instructions and restrictions men- tioned on page 6 of this manual.

DO NOT exceed the maximum allowed equivalent length given in tables on page 7. When joining various components of the vent system and air intake piping, proper sealant must be used (see page 6).

Install horizontal vent pipe with seams on the top. Connect and seal air intake piping to air intake collar of the boiler. Adjust the air pipe support to hold air intake pipe securely (See Figure 2).

Figure 11. Vent/Air Intake Termination

Image 13
Contents Victory Vsph Table of ContentsVictory Vsph Models Ratings and DimensionsBoiler Input No. Model Btuh Sections Location and Identification of Parts Base AssemblyNatural GAS-FIRED Boiler Location SafetyLiquefied Petroleum L.P. Propane GAS-FIRED Boiler Location Boiler FoundationDirect Vent Installation NON-DIRECT Vent InstallationVenting Application Boiler Room AIR Supply and VentilationFlue and AIR Intake Restrictions AIR Intake Pipe Material000 Ft 000 7,500 Ft 500 10,000 Ft VENT/AIR Intake Termination Installation Venting InstallationSidewall Venting NON-DIRECT Vent Vent Termination Location and ClearancesNon-direct vent, side wall venting Victory Vsph Models NON Direct VENT, Sidewall VentingAL 29-4C is a Registered Trademark of Allegheny Ludlum Corp Victory Vsph Models Victory Vsph Models Direct VENT, Sidewall Venting Vent/Air Intake Termination Direct Vent Venting and AIR Intake Through a RoofDirect VENT, Venting and AIR Intake Through a Roof Victory Vsph ModelsPower Supply Electrical WiringVenting and AIR Intake System Regular Inspection GAS PipingSchematic wiring diagram Multizoning of Vsph Boiler Multi Zoning Thermostat ConnectionsWater Piping Operating Instructions Safety Information Vsph Boiler Sequence of Operation Description of Operation Power TSTAT/CIRC LED Normal Operation Status of Indicator Lights LED’SLimit Press Switch Flame LED Integrated Boiler ControlLED’s Flashing Diagnostic Flash CodesIndication Remedy General Maintenance Care and MaintenanceCleaning II. Inspection During Heating SeasonBurners Fail to OPERATE- no Heat Cause General Troubleshooting Guide For Service PersonnelBurner will not Shut OFF Cause Not Enough Heat CauseBurner Short Cycles Cause Remedy If Replacement Parts are NeededFumes and GAS Odors Cause Remedy SLANT/FIN CORPORATION, Greenvale, N.Y Phone 516

VSPH-180, VSPH-60 specifications

Slant/Fin is a renowned name in the heating industry, renowned for its innovation, quality, and efficiency. Among its popular offerings are the VSPH-180 and VSPH-60, two highly efficient gas-fired residential boilers designed to provide reliable heating for homes.

The VSPH-180 is a high-efficiency residential boiler that delivers exceptional heating performance while being mindful of energy consumption. It operates at an impressive AFUE (Annual Fuel Utilization Efficiency) rating of up to 95%, meaning it uses 95% of the fuel burned for heating, resulting in lower energy bills and reduced environmental impact. The VSPH-180 features a durable stainless steel heat exchanger that not only contributes to its efficiency but also prolongs the boiler's lifespan.

On the other hand, the VSPH-60 is a slightly smaller but equally efficient model that is perfect for apartments or smaller homes. It also boasts a remarkable AFUE rating of up to 95%, ensuring cost-effective heating solutions. The compact design of the VSPH-60 allows for easy installation in various locations, making it a versatile choice for homeowners seeking space-saving options without compromising on performance.

One of the standout technologies in both models is the modulating gas valve, which adjusts the burner’s output to match the heating demand. This feature enhances energy efficiency by preventing the boiler from working harder than necessary, ensuring consistent temperatures and reducing wear on the unit. Furthermore, both models are equipped with a built-in electronic ignition system, eliminating the need for a pilot light and adding convenience for homeowners.

The VSPH series is designed with maintenance ease in mind. It features a user-friendly control panel that provides easy access to critical information, allowing for straightforward diagnostics and service. Regular maintenance can be performed with minimal disruption, enabling owners to keep their systems running optimally throughout the heating season.

In conclusion, the Slant/Fin VSPH-180 and VSPH-60 represent excellence in residential heating technology. With high AFUE ratings, durable construction, and advanced features, both boilers provide efficient and reliable heating solutions, ensuring comfort and energy savings for homeowners.