USER INSTRUCTIONS

1.GENERAL

1.1Installation and servicing must be carried out by a competent person.

1.2In all correspondence, please quote the appliance type and serial number which can be found on the data badge located at the rear of the stove.

1.3Ensure curtains are not positioned above the stove, and that there is at least a clearance of 300mm between the sides of the stove and any curtains.

1.4If any cracks are observed in the glass panel, do not use appliance until the glass has been replaced.

1.5If, for any reason, the flue has to removed from the stove, the seals must be replaced in the inner telescopic section and the inner spigot.

1.6Do not obstruct the flue terminal in any way i.e. by planting flowers, trees, shrubs etc in the near vicinity, or by leaning objects up against the terminal guard.

1.7Do not use a garden sprinkler so as to allow excessive amounts of water into the flue terminal.

1.8Do not stand or place objects on the terminal guard as this will deform.

1.9This product is guaranteed for 2 years from the date of installation, as set out in the terms and conditions of sale between Gazco and your local Gazco dealer. Please consult with your local Gazco dealer if you have any questions. In all correspondence always quote the Model No. and Serial No.

1.10The manufacturer considers the full outer casing of this stove to be a working surface. It will become hot whilst in operation. A suitable guard is recommended to protect young children, the aged and infirm.

Please ensure the commissioning checklist is completed by your installer, as this is a requirement of your Guarantee.

2.LIGHTING THE STOVE

2.1Locate the control valve on the appliance. There are two control knobs on the valve, the right hand knob controls the pilot ignition and the left hand knob controls the main burner.

2.2If your appliance has already been upgraded to battery remote control, please refer to the instructions provided with the upgrade to operate the remote control. The following instructions will work for either situation.

1

AR0914

2.3Ensure that the left-hand control knob is pointing to off ()

2.4Ensure that the right hand control knob is pointing to off ( ).

2.5Press in the right hand control knob and rotate it anticlockwise until a click is heard (keep pressing in) and the knob is pointing to pilot ( ). The pilot should now light. If the pilot has not lit, repeat the procedure until it does.

2.6Keep the control knob pressed in for 10 seconds and then release it, the pilot should stay alight. If the pilot goes out, repeat the procedure until does.

2.7If the pilot will not light after repeated attempts, contact the retailer or installer from whom the appliance was purchased.

2.8Turn the right hand control to point to main burner ( ) . The appliance can now be controlled using the left hand control knob.

2.9Turn the left hand control knob to point to low fire ( ) the main burner will light on low. The burner can now be controlled between low and high settings. Turn the control knob anti-clockwise to increase the flame height and clockwise to decrease the flame height.

THE YELLOW FLAMES WILL APPEAR WHEN THE FIRE HAS GAINED SUFFICIENT HEAT - TYPICALLY 10 TO 20 MINUTES.

IF THE APPLIANCE IS EXTINGUISHED OR GOES OUT IN USE, WAIT 3 MINUTES BEFORE ATTEMPTING TO RELIGHT THE APPLIANCE.

3.TURNING OFF THE STOVE

3.1To turn the stove off, locate the control valve, turn the left- hand control knob until it points to off (). The main burner will go out leaving the pilot burning.

3.2To turn the pilot off, locate the control valve, turn the right- hand control knob until it points to off (), the pilot will go out.

4.UPGRADING YOUR STOVE

4.1Your stove is fitted with a control valve that can be easily upgraded to battery powered remote control. This upgrade can be fitted by anyone capable of simple DIY jobs and requires no special training. There are two versions of this control which can be obtained through your local Gazco stockist.

4.2STANDARD REMOTE CONTROL This remote control can control the gas appliance after the pilot has been lit. It can turn the main burner on and regulate it from low through to high and back again. It can turn the main burner off leaving the pilot burning. GAZCO PART NUMBER 8455.

4.3THERMOSTATIC AND TIMER REMOTE CONTROL This remote control can control the gas appliance after the pilot has been lit. In ‘MANUAL MODE’ it can be used to turn the main burner on and manually regulate it from low through to high and back again. It can also be used to turn the main burner off leaving the pilot burning. In ‘AUTO MODE’ it will automatically regulate the room temperature. In ‘TIMER MODE’ it will turn the fire on and off according to a pre-set programme and automatically regulate the room temperature during two on periods. GAZCO PART NUMBER 8456.

4

Image 4
Contents Clarendon & Ashdon Log Effect Stove Range Contents Flue Check Pass Fail Appliance Commissioning ChecklistGAS Check User Instructions GeneralLighting the Stove Turning OFF the StoveHandling & Disposal of Fire Ceramics Cleaning the FireFuel BED Arrangements Never Operate the Stove When the Door is Removed Installation Details Flame Failure Device‘RUNNING IN’ ServicingInstallation Instructions Technical SpecificationFlue and Chimney Requirements Site RequirementsTimber Framed Buildings Rear Flue TOP ExitALL Appliances TOP Flue UP & OUT with Additional BendOptional Extra Flue Lengths & Bends Installation of the GAS Supply VentilationAppliance Location Minimum ClearanceInstallation Control UpgradeSafety Precautions Installation of the StoveDo not FIX the Flue AT this Stage Vertical & Horizontal Flue Do not Attempt to Shorten ANY Other Section of Flue PipeTable a TOP Exit Vertical only Including Offset TOP Exit Vertical FlueRemove ANY Cardboard Fitment Remaining Fuelbed Arrangements Lighting Commissioning CommissioningServicing / Fault Finding Charts Servicing InstructionsServicing Requirements Ignition Functional CheckFlame Failure Functional Check Pilot will not Stay LIT or Fire Goes OUT in USEMain Burner Replacing PartsPilot Unit Ignition Lead Magnetic Safety Valve PiezoGAS Valve Main InjectorChanging Between GAS Types Primary Aeration PlateShort Spares List Service Records Member of the Stovax Group