Stovax 8545LUC, P8545LUC manual Installation, Control Upgrade, Safety Precautions, Rear Exit Flue

Page 13

INSTALLATION INSTRUCTIONS

INSTALLATION

IMPORTANT: ENSURE THAT THE APPLIANCE IS CORRECTLY ADJUSTED FOR THE GAS TYPE AND CATEGORY APPLICABLE IN THE COUNTRY OF USE.

REFER TO DATABADGE AND TECHNICAL SPECIFICATIONS OF THIS BOOKLET.

FOR DETAILS OF CHANGING BETWEEN GAS TYPES REFER TO SECTION 10, REPLACING PARTS.

1.CONTROL UPGRADE

1.1This stove is fitted with a control valve that can be easily upgraded to battery powered remote control. There are two versions of this control which can be obtained through your local Gazco stockist.

1.2This upgrade can be fitted before or after installation but if side clearances are limited then it will be easier to upgrade the stove before installation. Full instructions are included with the kit.

1.3STANDARD REMOTE CONTROL This remote control can control the gas appliance after the pilot has been lit. It can turn the main burner on and regulate it from low through to high and back again. It can turn the main burner off leaving the pilot burning. GAZCO PART NUMBER 8455.

1.4THERMOSTATIC AND TIMER REMOTE CONTROL This remote control can control the gas appliance after the pilot has been lit. In "MANUAL MODE" it can be used to turn the main burner on and manually regulate it from low through to high and back again. It can also be used to turn the main burner off leaving the pilot burning. In "AUTO MODE" it will automatically regulate the room temperature. In "TIMER MODE" it will turn the fire on and off according to a pre-set programme and automatically regulate the room temperature during two on periods. GAZCO PART NUMBER 8456.

2.SAFETY PRECAUTIONS

2.1This appliance must be installed in accordance with the rules in force, and used only in a sufficiently ventilated space. Please read these instructions before installation and use of this appliance.

2.2These instructions, must be left intact with the user.

2.3Do not attempt to burn rubbish on this appliance.

2.4In your own interest, and those of safety, this appliance must be installed by a competent person in accordance with local and national codes of practice. Failure to install the appliance correctly could lead to prosecution.

2.5Keep all plastic bags away from young children.

2.6Do not place any object on, or near to the stove. Allow adequate clearance above the stove.

IF THE APPLAINCE IS EXTINGUISHED OR GOES OUT I N USE, WAIT 3 MINUTES BEFORE ATTEMPTING TO RELIGHT THE APPLIANCE.

3. INSTALLATION OF THE STOVE

NOTE: THE CAST IRON DOOR IS HEAVY, TAKE EXTREME CARE WHEN HANDLING TO AVOID DAMAGING THE OUTER CASING.

3.1Remove the outer sleeve and associated packaging from the stove. The ceramic logs are located behind the door. Remove the cast iron door using the tool provided. Remove the box and place in a safe location.

REFER TO SITE REQUIREMENTS SECTION FOR ALL FLUE OPTIONS

The appliance is suitable for top or rear flue exit. If a rear flue has been purchased proceed to 3.1 below. If a top exit is required, proceed to 3.2.

.

3.1 REAR EXIT FLUE

WALL THICKNESS

MIN

200mm

MAX

600mm

 

 

 

 

 

3.1.3Remove the adjustable flue assembly and terminal guard from the box. Take care not to lose the fixings.

3.1.4Decide on the final stove position and ensure that all external flue terminal clearances are complied with, See Section 1, Site Requirements. Mark the centreline of the appliance on the wall and mark the height from the top of the hearth to the centre of the flue. See diagram 1.

1

AR0605

TAKE CARE WHEN MARKING OUT FOR THE FLUE. IT IS DIFFICULT TO MOVE AFTER INSTALLATION.

A 152mm (6") diameter hole is required to install the flue. This can be achieved by either:

a)Core Drill.

b)Hammer & Chisel.

It is advisable to drill small holes around the circumference when using method b). Make good at both ends of the hole.

13

Image 13
Contents Clarendon & Ashdon Log Effect Stove Range Contents Flue Check Pass Fail Appliance Commissioning ChecklistGAS Check General User InstructionsLighting the Stove Turning OFF the StoveHandling & Disposal of Fire Ceramics Cleaning the FireFuel BED Arrangements Never Operate the Stove When the Door is Removed Flame Failure Device Installation Details‘RUNNING IN’ ServicingTechnical Specification Installation InstructionsFlue and Chimney Requirements Site RequirementsTimber Framed Buildings TOP Exit Rear FlueALL Appliances TOP Flue UP & OUT with Additional BendOptional Extra Flue Lengths & Bends Ventilation Installation of the GAS SupplyAppliance Location Minimum ClearanceControl Upgrade InstallationSafety Precautions Installation of the StoveDo not FIX the Flue AT this Stage Do not Attempt to Shorten ANY Other Section of Flue Pipe Vertical & Horizontal FlueTable a TOP Exit Vertical only Including Offset TOP Exit Vertical FlueRemove ANY Cardboard Fitment Remaining Fuelbed Arrangements Lighting Commissioning CommissioningServicing Instructions Servicing / Fault Finding ChartsServicing Requirements Ignition Functional CheckPilot will not Stay LIT or Fire Goes OUT in USE Flame Failure Functional CheckMain Burner Replacing PartsPilot Unit Ignition Lead Piezo Magnetic Safety ValveGAS Valve Main InjectorChanging Between GAS Types Primary Aeration PlateShort Spares List Service Records Member of the Stovax Group