INSTALLATION INSTRUCTIONS

INSTALLATION

3.1.5To set the flue length, measure the total wall thickness, then add 65mm. This total flue length will give the minimum clearance of 50mm between the rear of the stove and the wall. To cut the flue to length using a hacksaw, first insert the square cardboard fitment into the flue. This will support the inner flue. Cut through the flue and fitment. See diagram

2. ENSURE THE REMAINING FITMENT IS REMOVED FROM THE FLUE. File the cut edges of the flue smooth.

2

AR0630

3.1.6From outside, locate the flue assembly into the hole until the terminal is flat against the wall. Ensure the terminal is vertical. NOTE THE ORIENTATION OF THE TERMINAL.

See diagram 3. Mark the four fixing holes, remove the terminal and drill the holes, inserting the rawplugs supplied.

DO NOT FIX THE FLUE AT THIS STAGE.

3.1.7Position the stove ensuring all appropriate clearances are observed.

3.1.8Before fixing the flue in the wall, apply a bead of suitable weatherproof sealant (silicone or similar) around the perimeter of the back face of the terminal B Diagram 3. Feed the flue through the wall ensuring it travels smoothly. Working from inside, engage the flue in the inner and outer spigots, making sure the rubber seals on the spigots are not damaged.

From the outside, insert the four screws in the flanges of the flue terminal ensuring the sealant has formed a water tight joint to the wall. Finally secure the flue to the spigot by drilling a 3.5mm hole through the larger hole in the spigot and insert the stainless steel screw provided; refer to C in Diagram 3.

3

AR0606

Any terminal which is less than 2 meters above any access (level ground, balcony or above a flat roof to which people have access), is to be fitted with the guard supplied, see diagram 4.

4

AR0603

14

Image 14
Contents Clarendon & Ashdon Log Effect Stove Range Contents GAS Check Appliance Commissioning ChecklistFlue Check Pass Fail Lighting the Stove User InstructionsGeneral Turning OFF the StoveFuel BED Arrangements Cleaning the FireHandling & Disposal of Fire Ceramics Never Operate the Stove When the Door is Removed ‘RUNNING IN’ Installation DetailsFlame Failure Device ServicingInstallation Instructions Technical SpecificationTimber Framed Buildings Site RequirementsFlue and Chimney Requirements Rear Flue TOP ExitOptional Extra Flue Lengths & Bends TOP Flue UP & OUT with Additional BendALL Appliances Appliance Location Installation of the GAS SupplyVentilation Minimum ClearanceSafety Precautions InstallationControl Upgrade Installation of the StoveDo not FIX the Flue AT this Stage Vertical & Horizontal Flue Do not Attempt to Shorten ANY Other Section of Flue PipeRemove ANY Cardboard Fitment Remaining TOP Exit Vertical FlueTable a TOP Exit Vertical only Including Offset Fuelbed Arrangements Lighting Commissioning CommissioningServicing Requirements Servicing / Fault Finding ChartsServicing Instructions Ignition Functional CheckFlame Failure Functional Check Pilot will not Stay LIT or Fire Goes OUT in USEPilot Unit Replacing PartsMain Burner Ignition Lead GAS Valve Magnetic Safety ValvePiezo Main InjectorShort Spares List Primary Aeration PlateChanging Between GAS Types Service Records Member of the Stovax Group