Stovax 8545LUC, P8545LUC Primary Aeration Plate, Changing Between GAS Types, Short Spares List

Page 25

SERVICING INSTRUCTIONS

REPLACING PARTS

8.4Holding the injector with a spanner, undo the feed pipe.

NOTE: THE ORIENTATION OF THE INJECTOR.

8.5Reassemble in reverse order, turn on the gas supply and check for any leaks.

9.PRIMARY AERATION PLATE

9.1Turn the gas supply off at the isolation device.

9.2Refer to section 2 to remove the main burner.

9.3Remove the two screws on the burner skin to detach the venturi cover from the venturi. Slide the venturi cover off the venturi as per diagram 13.

13

AR1608

9.4Refer to the technical specification and databadge to check the gas type and its required aeration plate. Change the aeration plate, if necessary.

14

AR0619

9.5Reassemble in reverse order with correct aeration plate(s).

Note: Even if no aeration plate is required, the small screw(s) must be replaced.

10. CHANGING BETWEEN GAS TYPES

In order to change between gas types, it will be necessary to change the following items:

-Pilot Injector

-Control Valve

-Main Injector

-Main Burner

-Aeration Plate

-Databadge

The relevant parts can be ordered from the parts list, always quote the appliance type and serial number when ordering spare parts.

NOTE: THE CONTROL VALVE IS FACTORY PRESET FOR THE CORRECT GAS TYPE AND MODEL, A NEW UNIT WILL NEED TO BE ORDERED WHEN CHANGING BETWEEN GAS TYPES.

11. CONTROL UPGRADE

See section 4 in User Instructions.

12. SHORT SPARES LIST

Short spares list Bal flue

Component

NG

LPG

 

 

G20

G30

 

G31

 

20mb

29mb

 

37mb

Main Injector

IN0045

IN0030

 

IN0030

Aeration plate

N/A

N/A

 

ME1350

Pilot injector

PI0026

PI0015

Burner assembly

GZ5369

GZ5388

Thermocouple

 

PI0011

 

Magnetic unit

 

GC0092

 

Electrode

 

PI0053

 

Pilot Gasket

 

PI0052

 

Gas valve

 

GC0088K

 

Ignition lead

 

GC0090

 

Complete log set

 

CEO583

 

Log A

 

CEO584

 

Log B

 

CEO585

 

Log C

 

CEO586

 

Log D

 

CEO587

 

Log E

 

CEO588

 

Left ash panel

 

CEO589

 

Right ash panel

 

CEO590

 

Standard upgrade kit

 

8455

 

 

Thermostat/timer kit

 

8456

 

 

25

Image 25
Contents Clarendon & Ashdon Log Effect Stove Range Contents Flue Check Pass Fail Appliance Commissioning ChecklistGAS Check General User InstructionsLighting the Stove Turning OFF the StoveHandling & Disposal of Fire Ceramics Cleaning the FireFuel BED Arrangements Never Operate the Stove When the Door is Removed Flame Failure Device Installation Details‘RUNNING IN’ ServicingTechnical Specification Installation InstructionsFlue and Chimney Requirements Site RequirementsTimber Framed Buildings TOP Exit Rear FlueALL Appliances TOP Flue UP & OUT with Additional BendOptional Extra Flue Lengths & Bends Ventilation Installation of the GAS SupplyAppliance Location Minimum ClearanceControl Upgrade InstallationSafety Precautions Installation of the StoveDo not FIX the Flue AT this Stage Do not Attempt to Shorten ANY Other Section of Flue Pipe Vertical & Horizontal FlueTable a TOP Exit Vertical only Including Offset TOP Exit Vertical FlueRemove ANY Cardboard Fitment Remaining Fuelbed Arrangements Lighting Commissioning CommissioningServicing Instructions Servicing / Fault Finding ChartsServicing Requirements Ignition Functional CheckPilot will not Stay LIT or Fire Goes OUT in USE Flame Failure Functional CheckMain Burner Replacing PartsPilot Unit Ignition Lead Piezo Magnetic Safety ValveGAS Valve Main InjectorChanging Between GAS Types Primary Aeration PlateShort Spares List Service Records Member of the Stovax Group