Stovax 8544LUC-P8544LUC, 8545LUC, P8545LUC TOP Flue UP & OUT with Additional Bend, ALL Appliances

Page 11

INSTALLATION INSTRUCTIONS

SITE REQUIREMENTS

1.5TOP FLUE UP & OUT WITH ADDITIONAL BEND

Any additional bend may be used on the horizontal section (either 45° or 90°) but the overall horizontal flue run will be reduced.

Refer to diagram 4.

4

AR1300

1.6TOP FLUE VERTICAL KIT (8524/8524AN) -

ALL APPLIANCES

Vertical from the top of the appliance. (See diagram 5). A minimum vertical rise of 3m (9'10") to a maximum of 10m (32'10")

The basic kit comprises: 2 x 1m lengths

1 x 1m terminal lengths

1 x 52mm restrictor

1 x 47mm restrictor

Extra lengths may be added (see section 1.5), with reference to diagram 4 and the installation instructions of the appliance.

Refer to Table A under 3.3, Installation to identify when to use each restrictor.

1.7TOP FLUE VERTICAL OFFSET KIT (8530/8530AN) – ALL APPLIANCES

Used with kit 8524 only, (see diagram 5). A minimum rise of 500mm (191/2") is required to the first bend.

5

AR1299

1.8OPTIONAL EXTRA FLUE LENGTHS & BENDS

Nominal

Actual

Stainless

Anthracite

Length

Length

Finish

Finish

200mm

140mm

8527

8527AN

500mm

440mm

8528

8528AN

1000mm

940mm

8529

8529AN

45° Bend

N/A

8507

8507AN

90° Bend

N/A

8508

8508AN

Optional Flue Collar

N/A

8548

(Stoves Only)

 

 

11

Image 11
Contents Clarendon & Ashdon Log Effect Stove Range Contents GAS Check Appliance Commissioning ChecklistFlue Check Pass Fail Turning OFF the Stove User InstructionsGeneral Lighting the StoveFuel BED Arrangements Cleaning the FireHandling & Disposal of Fire Ceramics Never Operate the Stove When the Door is Removed Servicing Installation DetailsFlame Failure Device ‘RUNNING IN’Technical Specification Installation InstructionsTimber Framed Buildings Site RequirementsFlue and Chimney Requirements TOP Exit Rear FlueOptional Extra Flue Lengths & Bends TOP Flue UP & OUT with Additional BendALL Appliances Minimum Clearance Installation of the GAS SupplyVentilation Appliance LocationInstallation of the Stove InstallationControl Upgrade Safety PrecautionsDo not FIX the Flue AT this Stage Do not Attempt to Shorten ANY Other Section of Flue Pipe Vertical & Horizontal FlueRemove ANY Cardboard Fitment Remaining TOP Exit Vertical FlueTable a TOP Exit Vertical only Including Offset Fuelbed Arrangements Lighting Commissioning CommissioningIgnition Functional Check Servicing / Fault Finding ChartsServicing Instructions Servicing RequirementsPilot will not Stay LIT or Fire Goes OUT in USE Flame Failure Functional CheckPilot Unit Replacing PartsMain Burner Ignition Lead Main Injector Magnetic Safety ValvePiezo GAS ValveShort Spares List Primary Aeration PlateChanging Between GAS Types Service Records Member of the Stovax Group