Stovax 8544LUC-P8544LUC manual Flame Failure Device, ‘Running In’, Servicing, Installation Details

Page 7

USER INSTRUCTIONS

8.THE FLAME FAILURE DEVICE

8.1This is a safety feature incorporated in all GAZCO fires which automatically switches off the gas supply if the pilot light goes out and fails to heat the thermocouple.

9.‘RUNNING IN’

9.1The surface coating on your GAZCO fires will "burn off" during the first 24 hour of use, producing a harmless and temporary odour. This will disappear after the short period of use. If the odour persists, ask your installer for advice.

10.SERVICING

10.1The fire must be serviced every 12 months by a qualified Gas Engineer. In all correspondence, always quote the appliance type and serial number, which may be found on the data badge.

11.INSTALLATION DETAILS

11.1To assist in any future correspondence, your installer should have completed the commissioning sheet at the front of this manual. This records the essential installation details of this appliance. In all correspondence always quote the Model No. and Serial No.

7

Image 7
Contents Clarendon & Ashdon Log Effect Stove Range Contents Flue Check Pass Fail Appliance Commissioning ChecklistGAS Check Turning OFF the Stove User InstructionsGeneral Lighting the StoveHandling & Disposal of Fire Ceramics Cleaning the FireFuel BED Arrangements Never Operate the Stove When the Door is Removed Servicing Installation DetailsFlame Failure Device ‘RUNNING IN’Technical Specification Installation InstructionsFlue and Chimney Requirements Site RequirementsTimber Framed Buildings TOP Exit Rear FlueALL Appliances TOP Flue UP & OUT with Additional BendOptional Extra Flue Lengths & Bends Minimum Clearance Installation of the GAS SupplyVentilation Appliance LocationInstallation of the Stove InstallationControl Upgrade Safety PrecautionsDo not FIX the Flue AT this Stage Do not Attempt to Shorten ANY Other Section of Flue Pipe Vertical & Horizontal FlueTable a TOP Exit Vertical only Including Offset TOP Exit Vertical FlueRemove ANY Cardboard Fitment Remaining Fuelbed Arrangements Lighting Commissioning CommissioningIgnition Functional Check Servicing / Fault Finding ChartsServicing Instructions Servicing RequirementsPilot will not Stay LIT or Fire Goes OUT in USE Flame Failure Functional CheckMain Burner Replacing PartsPilot Unit Ignition Lead Main Injector Magnetic Safety ValvePiezo GAS ValveChanging Between GAS Types Primary Aeration PlateShort Spares List Service Records Member of the Stovax Group