Vulcan-Hart VL3GSS, VL3GMS, VL2GMS, VL3GAS, VL2GAS Heater Contactors, Steam Coil, Heating Elements

Page 21

VL SERIES STEAMERS - REMOVAL AND REPLACEMENT OF PARTS

HEATER CONTACTORS

 

REGENERATED STEAM MODELS

 

 

(STEAM COIL)

WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AT THE MAIN CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT BOX INDICATING THE CIRCUIT IS BEING SERVICED.

1.Open the cabinet base doors, remove the two screws from the contactor box cover and lift cover off.

2.Disconnect the electrical lead wires to the coil and the power supply wires from the contactor being replaced.

3.Remove the screws form the base of the contactor and lift out.

4.Reverse procedure to install and check for proper operation.

HEATING ELEMENTS

WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AT THE MAIN CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT BOX INDICATING THE CIRCUIT IS BEING SERVICED.

1.Open the cabinet base doors, remove the two screws from the contactor box cover and lift cover off.

2.Disconnect the electrical lead wires to the element being replaced.

3.Remove the bolts securing the heating element flange to the boiler and lift the element out.

4.Clean the mating surface of the boiler and install a new flange gasket and heating element.

5.Check for leaks and proper operation.

WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AT THE MAIN CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT BOX INDICATING THE CIRCUIT IS BEING SERVICED.

WARNING: SHUT OFF THE STEAM SUPPLY BEFORE SERVICING THE UNIT.

1.Disconnect pipe unions in the steam supply line to the coils and in the condensate discharge line from the coils.

2.Remove header that supplies steam to the coils by disconnecting union at each coil.

3.Remove coil condensate collection header.

4.Remove bolts securing the coil being replaced and pull coil forward.

5.Clean the mating surfaces of the steam coil flange and the boiler.

6.Reverse procedure to install a new steam coil and gasket.

7.Check steamer for proper operation.

Page 21 of 88

Image 21
Contents VL Boiler Base Series Convection Steamers Table of Contents VL Series Steamers Water Conditioning IntroductionTools SpecificationsElectric Steamers Gas SteamersElectrically Powered Steam Boiler Gas Powered Steam BoilerRegenerated Steam Powered Boiler Steamer OperationBoiler Blowdown and Steamer Shut off Direct Steam Powered CookerAutomatic blowdown Manual blowdownStandard Automatic Prevent Cycling Pressure Switch Water Level Gauge AssemblyHigh Limit Pressure Switch Power SwitchDelime Port Assembly Handhole Cover AssemblyBoiler Pressure Gauge Check ValveCooking Timer Compartment Power SwitchThermal Switch Load Compensator Cooking Light RedRemoval and Replacement of Parts VL Series Steamers Removal and Replacement of Parts Cooking Compartment Controls Component Configurations Water Level Controls LOW Level CUT OFF and Differential Water Level Gauge AssemblySolid State Electro MechanicalBoiler Assembly High Limit Thermostat Boiler Fill and Cold Water Condenser Solenoid Valves GAS Combination Control ValveGasket Compartment Gasket and Door Screw NUT, Door and BushingsDoor Screw Nut Door and BushingHeater Contactors Steam CoilHeating Elements Clean-Out All Boiler Models BoilerInspection Deliming Only Models with Deliming Port Assembly Water Level Controls Test Solid State Low level Cut-Off & Differential ControlElectro Mechanical Low level Cut-Off & Differential Control Water Level Probes Compartment Pressure Adjustment DisassemblyFill and Cold Water Solenoid Valves Boiler Blowdown Drain Solenoid Valve Boiler not Filling with WaterNewer Models Boiler Slow to PressurizeOlder Models All Models With BoilerElectric Models Inlet Water StrainerDirect Steam Models Regenerated Steam Coil SteamersVL Series Steamer Service Procedures and Adjustments Air Shutter Adjustment GAS BurnersAutomatic Ignition Systems GAS Models Spark Ignition Control Test TerminalsGAS Manifold Pressure Adjustment Regenerated Steam Older Models Heater Contactors Direct Steam ModelsVL Series Steamer Service Procedures and Adjustments Thermal Switch Prevent Automatic Models Steam Gate Valves Water Level Controls Electrical OperationSolid State Auxiliary Low Level Cut-Off Electro Mechanical Low level Cut-Off & Differential Control Electro Mechanical Auxiliary Low Level Cut-Off Initial Fill and Preheat Sequence of OperationVL Series Steamer Electrical Operation Water Refill After Initial Fill Cook CycleBoiler Blowdown/drain Electric ModelsCook Cycle Water Refill After Initial Fill Purposely Left Blank Manual Ignition, Standard Controls Electronic Ignition, Standard Controls Manual Ignition, CSD-1 Code Controls Electronic Ignition, CSD-1 Code Controls VL Series Steamer Electrical Operation Manual Ignition, Standard Controls VL Series Steamer Electrical Operation Electronic Ignition, Standard Controls VL Series Steamer Electrical Operation Manual Ignition, CSD-1 Code Controls VL Series Steamer Electrical Operation Electronic Ignition, CSD-1 Code Controls VL Series Steamer Electrical Operation Auto Blowdown, Standard Controls Auto Blowdown, Cal-Code Controls Auto Blowdown, Standard Controls contactor 1 std VL Series Steamer Electrical Operation Auto Blowdown, Standard Controls contactors 2 std VL Series Steamer Electrical Operation Manual Blowdown, Cal-Code Controls contactors 1 std aux VL Series Steamer Electrical Operation Auto Blowdown, Cal-Code Controls contactors 1 std aux VL Series Steamer Electrical Operation Auto Blowdown, Cal-Code Controls contactors 2 std aux VL Series Steamer Electrical Operation Manual Blowdown, Cal-Code Controls contactors 2 std aux VL Series Steamer Electrical Operation Standard and Cal-Code/CSD-1 Controls See Schematic and Wiring Diagrams Compartment Controls Manual Blowdown Older Models Auto Blowdown Older Models Schematic and Wiring Diagrams Compartment Controls Automatic Standard Manual ALL Models TroubleshootingContacts not closing to power boiler fill solenoid Schematic and Wiring Diagrams GAS Models only Symptom Possible CausesPilot not adjusted correctly. See Pilot

VL2GPS, VL3GPS, VL3GSS, VL2GSS, VL2GAS specifications

Vulcan-Hart is well-known in the commercial cooking equipment industry, providing durable and efficient products that cater to the needs of restaurants and foodservice operations. Their line of griddles, namely the VL3GAS, VL3GPS, VL3GMS, VL2GAS, and VL2GPS, showcases their commitment to high-quality performance and innovative cooking technologies.

The Vulcan-Hart VL3GAS is a gas griddle, featuring a robust stainless steel construction that ensures longevity and resilience in a bustling kitchen environment. It offers a smooth, hot cooking surface that allows for optimal heat retention and distribution, ensuring that food cooks evenly. With a 3/4-inch thick steel plate, it provides excellent thermal conductivity, making it ideal for high-volume cooking. This model is designed with easy-to-use controls, which makes it convenient for chefs to operate.

The VL3GPS model is a gas-powered griddle that comes equipped with a patented grease management system, which aids in maintaining a cleaner cooking environment. This system helps to separate grease from food and minimizes flare-ups, enhancing safety during cooking. Additionally, the griddle features a temperature control that allows chefs to set precise cooking temperatures, ensuring consistent results.

Moving to the VL3GMS, this model introduces increased versatility with its combination of gas and optional electric features. It’s tailored for establishments that require flexibility in their cooking strategies. The VL3GMS is also designed with a spacious cooking surface, making it suitable for preparing a wide array of dishes simultaneously.

The VL2GAS is a two-burner gas griddle that is specifically tailored for smaller kitchen operations or those with limited space. Its compact design does not compromise on performance, still providing a durable cooking surface and reliable temperature control. This model is ideal for smaller cafes or food trucks where space is at a premium.

Lastly, the VL2GPS complements the VL2GAS with its grease management system. This enhances hygiene and ensures that cooking remains efficient and safe. Both VL2 models offer easy startup and shutdown procedures, making them user-friendly for chefs working in fast-paced environments.

Overall, the Vulcan-Hart VL series griddles combine quality construction, innovative technology, and efficient design. Whether it’s the three-burner or two-burner options, these griddles meet the demands of commercial kitchens, providing reliable cooking solutions that serve the dynamic needs of the foodservice industry.