VL SERIES STEAMER - SERVICE PROCEDURES AND ADJUSTMENTS

THERMAL SWITCH - PREVENT

AND AUTOMATIC MODELS

The load compensator is a thermal switch in a stainless steel housing that screws into a 3/8 NPT fitting (newer models) on the left side wall of the compartment. The switch contacts should close when the compartment temperature reaches 180￿F, supplying power to the steam exhaust solenoid valve, pilot light and cooking timer motor.

1.Newer Models

A.This switch is NON-ADJUSTABLE. Check to see if the switch is operating properly as described below. If the switch is suspected to be malfunctioning, replace it and check for proper operation.

2.Older Models

D.If the cooking cycle is started normally, but the red light and timer do not come on or an abnormal amount of time elapses before they come on, then the load compensator is set too high. Also, if the timer stops, the red light goes out, and the buzzer does not sound after the compartment has exhausted the steam or if the time is set as usual for the product and the product is overcooked or if the time is set as usual for the product and the product is overcooked.

E.If there is too short a time between starting and the red light coming on, or if it comes on immediately, the load compensator is set too low. Also, if the time is set as usual for the product and the product is undercooked.

A.The switch can be adjusted by turning the slotted screw. Turn the screw clockwise to lower the closing temperature and counterclockwise to raise the closing temperature. Check the operation of the switch as described below. These models are ½ NPT.

The correct adjustment or verification of the load compensator can best be made by using a digital thermometer and thermocouple to sense the compartment temperature.

1.Position the thermocouple near the exposed bulb of the load compensator inside the compartment.

2.Close and seal the compartment. Pull the steam control arm handle forward, set the timer and turn the compartment power switch ON.

3.Monitor the thermocouple temperature, and adjust or verify (as applicable) the load compensator temperature.

A.The red light of the compartment switch should light when the thermocouple reads 185 ±7 ￿F.

B.After the cooking cycle ends and the compartment temperature lowers, the thermal switch should then re-open at 165 ±7 °F.

C.If the load compensator can not be adjusted correctly or the temperature is out side the allowable limits, then replace thermal switch and check for proper operation.

WATER LEVEL GAUGE

ASSEMBLY

1.Close the valve at the top and at the bottom of the gauge assembly.

2.Unscrew the packing nuts at the top and bottom of the glass tube.

3.Slide the glass tube upwards, until the bottom of the tube is clear of the fitting and lift it out.

4.Reinstall the tube and use new sealing washers. Do not over tighten the packing nuts, it could break the gauge glass.

5.Open the top and bottom valves fully.

6.Check for proper operation.

Page 36 of 88

Image 36
Contents VL Boiler Base Series Convection Steamers Table of Contents VL Series Steamers Introduction Water ConditioningSpecifications ToolsGas Steamers Electric SteamersGas Powered Steam Boiler Electrically Powered Steam BoilerRegenerated Steam Powered Boiler Steamer OperationDirect Steam Powered Cooker Boiler Blowdown and Steamer Shut offAutomatic blowdown Manual blowdownStandard Automatic Prevent Water Level Gauge Assembly Cycling Pressure SwitchHigh Limit Pressure Switch Power SwitchHandhole Cover Assembly Delime Port AssemblyBoiler Pressure Gauge Check ValveCompartment Power Switch Cooking TimerThermal Switch Load Compensator Cooking Light RedRemoval and Replacement of Parts VL Series Steamers Removal and Replacement of Parts Cooking Compartment Controls Component Configurations Water Level Gauge Assembly Water Level Controls LOW Level CUT OFF and DifferentialSolid State Electro MechanicalBoiler Assembly High Limit Thermostat GAS Combination Control Valve Boiler Fill and Cold Water Condenser Solenoid ValvesCompartment Gasket and Door Screw NUT, Door and Bushings GasketDoor Screw Nut Door and BushingHeater Contactors Steam CoilHeating Elements Clean-Out All Boiler Models BoilerInspection Deliming Only Models with Deliming Port Assembly Water Level Controls Test Solid State Low level Cut-Off & Differential ControlElectro Mechanical Low level Cut-Off & Differential Control Water Level Probes Compartment Pressure Adjustment DisassemblyFill and Cold Water Solenoid Valves Boiler not Filling with Water Boiler Blowdown Drain Solenoid ValveBoiler Slow to Pressurize Newer ModelsOlder Models All Models With BoilerInlet Water Strainer Electric ModelsDirect Steam Models Regenerated Steam Coil SteamersVL Series Steamer Service Procedures and Adjustments Air Shutter Adjustment GAS BurnersAutomatic Ignition Systems GAS Models Terminals Spark Ignition Control TestGAS Manifold Pressure Adjustment Direct Steam Models Regenerated Steam Older Models Heater ContactorsVL Series Steamer Service Procedures and Adjustments Thermal Switch Prevent Automatic Models Steam Gate Valves Electrical Operation Water Level ControlsSolid State Auxiliary Low Level Cut-Off Electro Mechanical Low level Cut-Off & Differential Control Electro Mechanical Auxiliary Low Level Cut-Off Sequence of Operation Initial Fill and PreheatVL Series Steamer Electrical Operation Cook Cycle Water Refill After Initial FillElectric Models Boiler Blowdown/drainCook Cycle Water Refill After Initial Fill Purposely Left Blank Manual Ignition, Standard Controls Electronic Ignition, Standard Controls Manual Ignition, CSD-1 Code Controls Electronic Ignition, CSD-1 Code Controls VL Series Steamer Electrical Operation Manual Ignition, Standard Controls VL Series Steamer Electrical Operation Electronic Ignition, Standard Controls VL Series Steamer Electrical Operation Manual Ignition, CSD-1 Code Controls VL Series Steamer Electrical Operation Electronic Ignition, CSD-1 Code Controls VL Series Steamer Electrical Operation Auto Blowdown, Standard Controls Auto Blowdown, Cal-Code Controls Auto Blowdown, Standard Controls contactor 1 std VL Series Steamer Electrical Operation Auto Blowdown, Standard Controls contactors 2 std VL Series Steamer Electrical Operation Manual Blowdown, Cal-Code Controls contactors 1 std aux VL Series Steamer Electrical Operation Auto Blowdown, Cal-Code Controls contactors 1 std aux VL Series Steamer Electrical Operation Auto Blowdown, Cal-Code Controls contactors 2 std aux VL Series Steamer Electrical Operation Manual Blowdown, Cal-Code Controls contactors 2 std aux VL Series Steamer Electrical Operation Standard and Cal-Code/CSD-1 Controls See Schematic and Wiring Diagrams Compartment Controls Manual Blowdown Older Models Auto Blowdown Older Models Schematic and Wiring Diagrams Compartment Controls Automatic Standard Manual Troubleshooting ALL ModelsContacts not closing to power boiler fill solenoid Schematic and Wiring Diagrams Symptom Possible Causes GAS Models onlyPilot not adjusted correctly. See Pilot

VL2GPS, VL3GPS, VL3GSS, VL2GSS, VL2GAS specifications

Vulcan-Hart is well-known in the commercial cooking equipment industry, providing durable and efficient products that cater to the needs of restaurants and foodservice operations. Their line of griddles, namely the VL3GAS, VL3GPS, VL3GMS, VL2GAS, and VL2GPS, showcases their commitment to high-quality performance and innovative cooking technologies.

The Vulcan-Hart VL3GAS is a gas griddle, featuring a robust stainless steel construction that ensures longevity and resilience in a bustling kitchen environment. It offers a smooth, hot cooking surface that allows for optimal heat retention and distribution, ensuring that food cooks evenly. With a 3/4-inch thick steel plate, it provides excellent thermal conductivity, making it ideal for high-volume cooking. This model is designed with easy-to-use controls, which makes it convenient for chefs to operate.

The VL3GPS model is a gas-powered griddle that comes equipped with a patented grease management system, which aids in maintaining a cleaner cooking environment. This system helps to separate grease from food and minimizes flare-ups, enhancing safety during cooking. Additionally, the griddle features a temperature control that allows chefs to set precise cooking temperatures, ensuring consistent results.

Moving to the VL3GMS, this model introduces increased versatility with its combination of gas and optional electric features. It’s tailored for establishments that require flexibility in their cooking strategies. The VL3GMS is also designed with a spacious cooking surface, making it suitable for preparing a wide array of dishes simultaneously.

The VL2GAS is a two-burner gas griddle that is specifically tailored for smaller kitchen operations or those with limited space. Its compact design does not compromise on performance, still providing a durable cooking surface and reliable temperature control. This model is ideal for smaller cafes or food trucks where space is at a premium.

Lastly, the VL2GPS complements the VL2GAS with its grease management system. This enhances hygiene and ensures that cooking remains efficient and safe. Both VL2 models offer easy startup and shutdown procedures, making them user-friendly for chefs working in fast-paced environments.

Overall, the Vulcan-Hart VL series griddles combine quality construction, innovative technology, and efficient design. Whether it’s the three-burner or two-burner options, these griddles meet the demands of commercial kitchens, providing reliable cooking solutions that serve the dynamic needs of the foodservice industry.