VL SERIES STEAMERS - GENERAL

STEAMER OPERATION

Ensure that all utility connections to the steamer have been made and are turned on.

On models that are CSD-1 equipped, amber colored lights for hi pressure and low water level will illuminate and stay on until the boiler is full and the manual reset switch pressed.

Gas Powered Steam Boiler

5.Open the cabinet door and turn main power switch ON. The red light will illuminate, water will begin filling the boiler and the blowdown solenoid valve will close. The boiler should fill, in four to eleven minutes. Observe water level gauge glass to verify that water is in boiler and that the level in the gauge glass is about half full. Both valves on gauge glass assembly must be open to fill the gauge. Older models equipped with a manual “ball” type blowdown valve must be closed for the boiler to fill. The cycling pressure switch will maintain the proper steam pressure in the boiler by cycling the heating system on and off to generate steam pressure.

A.On Models with Manual Ignition - The knob on the gas combination control valve has three positions (On-Pilot-Off) for control of main burners and pilot. Turn knob on gas combination valve to PILOT then depress and light pilot burner with a lit taper. Maintain knob in depressed position for about 30 seconds and release. Observe that pilot burner flame stays on. If the flame should go out, wait 5 minutes before relighting.

Turn knob on gas combination control valve to ON. If the water level in the boiler has reached the minimum level, burners will ignite and begin to heat the water in the boiler. After approximately 15 minutes, steam should be present for cooking product. Observe that the boiler pressure gauge indicates steam pressure of 9-11 psi for models with a pressure regulating valve or 4-6 psi for models without the valve.

B.On Models with Automatic Ignition - The knob on the gas combination control valve has two positions (On-Off) for control of main burners and pilot. For the automatic ignition system to work, the knob must be set in the ON position or gas for the pilot and main burners will not flow.

Also, the ignition control module ON/OFF/RESET switch must be in the ON position to operate. This switch is located on the upper left side of the electrical control box for the ignition control module. A red light will illuminate when the switch is in the ON position. DO NOT ATTEMPT TO MANUALLY LIGHT THE PILOT IN AN AUTOMATIC TYPE IGNITION SYSTEM.

After the main power switch is turned ON and the ignition control modules RESET switch is in the ON position, sparking will begin three seconds later to light the standing pilot. If the pilot lights, a signal is sent back through the ignition cable indicating the presence of pilot flame and sparking stops. If the water level in the boiler has reached the minimum level, the burners will ignite and begin to heat the water in the boiler. After approximately 15 minutes, steam should be present for cooking product. Observe that the boiler pressure gauge indicates a steam pressure of 9-11 psi for models with a pressure regulating valve or 4-6 psi for models without the valve. If a pilot flame is not established immediately, sparking will continue for 90 seconds. After that duration, the ignition control module will lock out and needs to be reset to start the pilot and burner lighting cycle again.

Electrically Powered Steam Boiler

Open the cabinet door and turn main power switch ON. The red light will illuminate, water will begin filling the boiler and the blowdown solenoid valve will close. The boiler should fill, in approximately 11 minutes. Observe water level gauge glass to verify that water is in boiler and that the level in the gauge glass is about half full. Both valves on gauge glass assembly must be open to fill the gauge. Older models equipped with a manual “ball” type blowdown valve must be closed for the boiler to fill. If the water level in the boiler has reached the minimum level, the heater contactors will close, the heaters will energize and begin to heat the water in the boiler. After approximately 15 minutes, steam should be present for cooking product. Observe that the boiler pressure gauge indicates steam pressure of 9-11 psi for models with a pressure regulating valve or 4-6 psi for models without the valve.

Regenerated Steam Powered Boiler

Open the cabinet door and turn main power switch ON. The pilot light will illuminate, water will begin filling the boiler and the blowdown solenoid valve will close. Models equipped with a manual “ball type” blowdown valve need to be closed for the boiler to fill. The boiler should fill, in approximately 15 minutes.

Page 7 of 88

Image 7
Contents VL Boiler Base Series Convection Steamers Table of Contents VL Series Steamers Water Conditioning IntroductionTools SpecificationsElectric Steamers Gas SteamersSteamer Operation Gas Powered Steam BoilerElectrically Powered Steam Boiler Regenerated Steam Powered BoilerManual blowdown Direct Steam Powered CookerBoiler Blowdown and Steamer Shut off Automatic blowdownStandard Automatic Prevent Power Switch Water Level Gauge AssemblyCycling Pressure Switch High Limit Pressure SwitchCheck Valve Handhole Cover AssemblyDelime Port Assembly Boiler Pressure GaugeCooking Light Red Compartment Power SwitchCooking Timer Thermal Switch Load CompensatorRemoval and Replacement of Parts VL Series Steamers Removal and Replacement of Parts Cooking Compartment Controls Component Configurations Electro Mechanical Water Level Gauge AssemblyWater Level Controls LOW Level CUT OFF and Differential Solid StateBoiler Assembly High Limit Thermostat Boiler Fill and Cold Water Condenser Solenoid Valves GAS Combination Control ValveDoor and Bushing Compartment Gasket and Door Screw NUT, Door and BushingsGasket Door Screw NutSteam Coil Heater ContactorsHeating Elements Boiler Clean-Out All Boiler ModelsInspection Deliming Only Models with Deliming Port Assembly Solid State Low level Cut-Off & Differential Control Water Level Controls TestElectro Mechanical Low level Cut-Off & Differential Control Water Level Probes Disassembly Compartment Pressure AdjustmentFill and Cold Water Solenoid Valves Boiler Blowdown Drain Solenoid Valve Boiler not Filling with WaterAll Models With Boiler Boiler Slow to PressurizeNewer Models Older ModelsRegenerated Steam Coil Steamers Inlet Water StrainerElectric Models Direct Steam ModelsVL Series Steamer Service Procedures and Adjustments GAS Burners Air Shutter AdjustmentAutomatic Ignition Systems GAS Models Spark Ignition Control Test TerminalsGAS Manifold Pressure Adjustment Regenerated Steam Older Models Heater Contactors Direct Steam ModelsVL Series Steamer Service Procedures and Adjustments Thermal Switch Prevent Automatic Models Steam Gate Valves Water Level Controls Electrical OperationSolid State Auxiliary Low Level Cut-Off Electro Mechanical Low level Cut-Off & Differential Control Electro Mechanical Auxiliary Low Level Cut-Off Initial Fill and Preheat Sequence of OperationVL Series Steamer Electrical Operation Water Refill After Initial Fill Cook CycleBoiler Blowdown/drain Electric ModelsCook Cycle Water Refill After Initial Fill Purposely Left Blank Manual Ignition, Standard Controls Electronic Ignition, Standard Controls Manual Ignition, CSD-1 Code Controls Electronic Ignition, CSD-1 Code Controls VL Series Steamer Electrical Operation Manual Ignition, Standard Controls VL Series Steamer Electrical Operation Electronic Ignition, Standard Controls VL Series Steamer Electrical Operation Manual Ignition, CSD-1 Code Controls VL Series Steamer Electrical Operation Electronic Ignition, CSD-1 Code Controls VL Series Steamer Electrical Operation Auto Blowdown, Standard Controls Auto Blowdown, Cal-Code Controls Auto Blowdown, Standard Controls contactor 1 std VL Series Steamer Electrical Operation Auto Blowdown, Standard Controls contactors 2 std VL Series Steamer Electrical Operation Manual Blowdown, Cal-Code Controls contactors 1 std aux VL Series Steamer Electrical Operation Auto Blowdown, Cal-Code Controls contactors 1 std aux VL Series Steamer Electrical Operation Auto Blowdown, Cal-Code Controls contactors 2 std aux VL Series Steamer Electrical Operation Manual Blowdown, Cal-Code Controls contactors 2 std aux VL Series Steamer Electrical Operation Standard and Cal-Code/CSD-1 Controls See Schematic and Wiring Diagrams Compartment Controls Manual Blowdown Older Models Auto Blowdown Older Models Schematic and Wiring Diagrams Compartment Controls Automatic Standard Manual ALL Models TroubleshootingContacts not closing to power boiler fill solenoid Schematic and Wiring Diagrams GAS Models only Symptom Possible CausesPilot not adjusted correctly. See Pilot

VL2GPS, VL3GPS, VL3GSS, VL2GSS, VL2GAS specifications

Vulcan-Hart is well-known in the commercial cooking equipment industry, providing durable and efficient products that cater to the needs of restaurants and foodservice operations. Their line of griddles, namely the VL3GAS, VL3GPS, VL3GMS, VL2GAS, and VL2GPS, showcases their commitment to high-quality performance and innovative cooking technologies.

The Vulcan-Hart VL3GAS is a gas griddle, featuring a robust stainless steel construction that ensures longevity and resilience in a bustling kitchen environment. It offers a smooth, hot cooking surface that allows for optimal heat retention and distribution, ensuring that food cooks evenly. With a 3/4-inch thick steel plate, it provides excellent thermal conductivity, making it ideal for high-volume cooking. This model is designed with easy-to-use controls, which makes it convenient for chefs to operate.

The VL3GPS model is a gas-powered griddle that comes equipped with a patented grease management system, which aids in maintaining a cleaner cooking environment. This system helps to separate grease from food and minimizes flare-ups, enhancing safety during cooking. Additionally, the griddle features a temperature control that allows chefs to set precise cooking temperatures, ensuring consistent results.

Moving to the VL3GMS, this model introduces increased versatility with its combination of gas and optional electric features. It’s tailored for establishments that require flexibility in their cooking strategies. The VL3GMS is also designed with a spacious cooking surface, making it suitable for preparing a wide array of dishes simultaneously.

The VL2GAS is a two-burner gas griddle that is specifically tailored for smaller kitchen operations or those with limited space. Its compact design does not compromise on performance, still providing a durable cooking surface and reliable temperature control. This model is ideal for smaller cafes or food trucks where space is at a premium.

Lastly, the VL2GPS complements the VL2GAS with its grease management system. This enhances hygiene and ensures that cooking remains efficient and safe. Both VL2 models offer easy startup and shutdown procedures, making them user-friendly for chefs working in fast-paced environments.

Overall, the Vulcan-Hart VL series griddles combine quality construction, innovative technology, and efficient design. Whether it’s the three-burner or two-burner options, these griddles meet the demands of commercial kitchens, providing reliable cooking solutions that serve the dynamic needs of the foodservice industry.