1.11.6 Replacing the MIB Board

1.11.5MIB (Manual Interface Board) Display Characters

A – Auto Mode – Auto Filtration enabled.

E – Drain or return valve is not in desired state. The display will alternate between E and the corresponding vat number. Ensure the actuator is plugged in and an error does not exist.

1.11.7 Control Power Reset SwitchThree horizontal lines indicate the AIF temperature sensor did not detect that the vat was full during auto filtration.

n – Network Error - An “n” displays for 10 seconds if no communication is received from the cooking computer within ten seconds after a power on or MIB reset.

P – Pan Switch – Filter pan is improperly seated. Filtration is suspended.

r – Reset Switch - Reset the vat closes all of the valves on the vat. If displayed for some time, there is probably a problem with the board.

1 – 5 – Numbers which correspond to the vats with either an “L” indicating the left side of a split vat or “r” indicating the right side of a split vat or a full vat. These numbers are displayed in manual mode.

1.11.6 Replacing the MIB Board

Disconnect the fryer from the electrical power supply. Remove the torx screws from the MIB cover, exposing the MIB board (see Figure 11). Removing the screw at top center lets the MIB board hinge down. Carefully remove the plugs on the rear of the board (see Figure 12). Replace with a new MIB board and reverse steps to reassemble. Once replaced, CYCLE POWER TO ENTIRE FRYER SYSTEM. See next section to reset control power. Check software version # and if necessary update the software. If a software update was necessary, follow the instructions to update the software on in section 1.15 ensuring the MIB reset button is pressed and held for five seconds at the end of the update to update the MIB.

Figure 11

Figure 12

1.11.7 Control Power Reset Switch

 

The control power reset switch is a momentary

 

rocker switch located behind the control box

 

(see Figures 13 and 14) above the JIB that

 

resets all power to all the computers and boards

 

in the fryer. It is necessary to reset all power

 

after replacing any computer or board. Press

 

and hold the switch for at least ten seconds

 

when resetting the control power to ensure

 

power has sufficiently drained from boards.

Figure 13

 

Figure 14 (Rear view of Control Box)

1-22

Page 29
Image 29
Frymaster BIELA14 manual Replacing the MIB Board, Control Power Reset Switch