8.Reconnect the element connector ensuring that the latches lock.
9.Insert the temperature probe leads into the
10.Reconnect the
11.Lower the element to the full down position.
12.Reinstall the tilt housing, back panels and contactor plug guard. Reposition the fryer under the exhaust hood, and reconnect it to the electrical power supply.
1.7Replacing Contactor Box Components
1.If replacing a contactor box component in boxes above the filter pan, first remove the filter pan and lid from the unit. If replacing components in fryers tht have ATO boxes, the ATO box may require removal.
2.Disconnect the fryer from the electrical power supply.
3.Remove the two screws securing the cover of the contactor box. The contactor boxes above the filter pan are accessed by sliding under the fryer. They are located to the left and right above the guide rails (see photo below). The contactor boxes for frypots not over the filter pan are accessed by opening the fryer door directly under the affected frypot.
Remove two screws to access contactor box components above the filter pan.