Frymaster BIELA14 manual Service Required Errors, Error Message, Explanation, 1-34

Models: BIELA14

1 96
Download 96 pages 23.21 Kb
Page 41
Image 41

1.14.3 Service Required Errors

A SERVICE REQUIRED error alternating with YES displays on the computer. After YES is pressed the alarm is silenced. The computer displays an error message from the list below three times with the location of the error. Then the computer displays SYSTEM ERROR FIXED? YES/NO. If yes is chosen, enter code 1111. If NO is chosen the system returns to cook mode for 15 minutes then redisplays error until issue is fixed.

Pressing the MIB reset button during any filter function will generate a “SERVICE REQUIRED” error.

This is a list of the service required errors and causes.

ERROR MESSAGE

EXPLANATION

PUMP NOT FILLING

Oil not returning to

vat quickly. Possible

 

problems: dirty pad, bad or missing O-rings,

 

tripped or defective filter pump, actuators or

 

linkage.

 

DRAIN VALVE NOT OPEN

Drain valve failed to open; the valve’s

 

position is unknown.

 

DRAIN VALVE NOT CLOSED

Drain valve failed to close; the valve’s

 

position is unknown.

 

RETURN VALVE NOT OPEN

Return valve failed to open; the valve’s

 

position is unknown.

 

RETURN VALVE NOT CLOSED

Return valve failed to close; the valve’s

 

position is unknown.

 

MIB BOARD

Problem with CAN communications; Check

 

for loose CAN connections between

 

computer and MIB board. MIB board failure

AIF BOARD

MIB detects AIF missing; AIF board failure

ATO BOARD

MIB detects ATO board connection lost;

 

ATO board failure

 

HIGH LIMIT FAILURE

High limit circuit has an issue

AIF PROBE

AIF RTD reading out of range

ATO PROBE

ATO RTD reading out of range

TEMP PROBE FAILURE

TEMP Probe reading out of range

MIB SOFTWARE

Internal MIB software error

INVALID CODE LOCATION

SD card removed during update

MISCONFIGURED ENERGY TYPE

Energy type in fryer setup is incorrect. (ie.

 

Set proper energy type gas or electric)

 

Press 1234 to enter setup to properly

 

configure fryer.

 

RTC INVALID DATE

The date is invalid.

Press 1234 to enter

 

setup to properly configure fryer and set

 

proper date.

 

1-34

Page 41
Image 41