Manual background

Problem

Probable Causes

 

A. Problem with the temperature

M3000 display shows

measuring circuitry including the probe.

B. Damaged computer wiring harness or

TEMP PROBE

connector.

FAILURE.

 

 

 

MAINT FILTER

Temperature too low.

(Manual Filter) won’t

start.

 

M3000 display shows

In non-dedicated mode, a product is

dropped that has a different setpoint that

REMOVE DISCARD.

the current vat temperature.

 

 

 

M3000 display shows

Failed computer, failed interface board,

HEATING

FAILURE.

open high-limit thermostat.

 

 

Computer will not go

 

into program mode or

Failed computer.

some buttons do not

 

actuate.

 

M3000 display shows

Computer in high-limit test mode.

HI 2 BAD.

 

 

M3000 display shows

 

HELP HI-2 or HIGH

Failed high-limit.

LIMIT FAILURE.

 

M3000 display shows

 

software for only

Loose or damaged harness

M3000 or MIB but not

 

all boards.

 

M3000 display shows

A. Three phase power cord unplugged or

low temp, heating

B.

circuit breaker is tripped.

Blown fuse

indicator cycles on and

C.

Failed computer.

off normally but fryer

D.

Damaged computer wiring harness.

does not heat.

E.

Open connection in high-limit circuit.

Corrective Action

A. This indicates a problem within the temperature measuring circuitry. Check resistance of probe, if faulty replace probe.

B.Swap the computer wiring harness with one known to be good. If problem is corrected, replace the harness.

Ensure fryer is at setpoint before starting

MAINT FILTER.

Remove and discard product. Press a cook button under the display with the error to remove the error. Reset the setpoint of the vat before trying to cook product.

Turn off the vat with the issue. The error is displayed if the fryer loses its ability to heat oil. It is also displayed when the oil temperature is above 450°F (232°C) and the high-limit thermostat has opened, halting the heating of the oil.

Replace computer

This is displayed during a test of the high- limit circuit to indicate if the high-limit has failed.

This is displayed to indicate the high-limit has failed.

Check that all harnesses between M3000’s, MIB, AIF and ATO are secure. Ensure 24VDC is present on pins 5 & 6 of J2 on MIB board and on J4 or J5 of AIF board. Check for loose or broken pins/wires. If the problem persists, swap out computer from one bank to another and cycle power on the fryer.

A.Ensure all cords are fully seated in the receptacles, locked into place and that circuit breakers are not tripped.

B.Check three amp fuse on front of control box.

C.Replace computer.

D.Replace computer wiring harness.

E.Check high limit circuit starting at the control box connector working to the high-limit.

1-32

Page 39
Image 39
Frymaster BIELA14 manual Problem, Probable Causes, Corrective Action