3.Slide the metal bezel up to release the bottom tabs, then slide the bezel down to disengage the upper tabs.

4.Remove the two screws from the upper corners of the computers and allow them to swing down (see illustration and photo on page 1-1).

5.Unplug the wiring harnesses and ground wires from the backs of the computers. Remove the computers by lifting them from the hinge slots in the control panel frame.

6.Remove the tilt housing and back panels from the fryer. The tilt housing must be removed first in order to remove the upper back panel.

7.To remove the tilt housing, remove the hex-head screws from the rear edge of the housing. The housing can be lifted straight up and off the fryer.

8.Remove the control panel by removing the screw in the center and the nuts on both sides.

9.Loosen the component boxes by removing the screws, which secure them in the cabinet.

10.Dismount the top cap by removing the nuts at each end that secure it to the cabinetry.

11.Remove the hex head screw that secures the front of the frypot to the cabinet cross brace.

12.Remove the top-connecting strip that covers the joint with the adjacent frypot.

13.Unscrew the nut located on the front of each section of drain tube, and remove the tube assembly from the fryer.

14.Remove the actuators from the drain and return valves and disconnect the wiring.

15.Disconnect any auto filtration probes and auto top off sensors and wiring.

16.At the rear of the fryer, unplug the 12-pin connector C-6 and, using a pin pusher, disconnect the high-limit thermostat leads. Disconnect any other probe wiring.

17.Disconnect the oil return flexline(s).

18.Raise the elements to the “up” position and disconnect the element springs.

19.Remove the machine screws and nuts that secure the element tube assembly to the frypot. Carefully lift the element assembly from the frypot and secure it to the cross brace on the rear of the fryer with wire ties or tape.

20.Carefully lift the frypot from the fryer and place it upside down on a stable work surface.

21.Recover the drain valve(s), oil return flexline connection fitting(s), actuators, AIF boards and high- limit thermostat(s) from the frypot. Clean the threads and apply LoctitePST 567 or equivalent sealant to the threads of the recovered parts and install them in the replacement frypot.

22.Carefully lower the replacement frypot into the fryer. Reinstall the hex head screw removed in step 11 to attach the frypot to the fryer.

1-9

Page 16
Image 16
Frymaster BIELA14 manual Disconnect the oil return flexlines