1.14.4 Error Log Codes

Refer to page 1-39, level 2 program for access to the E-log. The ten most recent errors are listed from A-J, with A being the most recent error.

Code

ERROR MESSAGE

EXPLANATION

E01

REMOVE DISCARD (Right)

A product cook is started on the right side of a split

 

 

vat or in a full vat that has a different setpoint other

 

 

than the current vat temperature.

E02

REMOVE DISCARD (Left)

A product cook is started on the right side of a split

 

 

vat or in a full vat that has a different setpoint other

 

 

than the current vat temperature.

E03

ERROR TEMP PROBE FAILURE

Temp probe reading out of range

E04

HI 2 BAD

High limit reading is out of range.

E05

HOT HI 1

High limit temperature is past more than 410°F

 

 

(210°C), or in CE countries, 395°F (202°C)

E06

HEATING FAILURE

A component has failed in the high limit circuit such

 

 

as computer, interface board, contactor or open-

 

 

high limit.

E07

ERROR MIB SOFTWARE

Internal MIB software error

E08

ERROR ATO BOARD

MIB detects ATO board connection lost; ATO

 

 

board failure

E09

ERROR PUMP NOT FILLING

Oil not returning to vat quickly. Possible problems:

 

 

dirty pad, bad or missing O-rings, tripped or

 

 

defective filter pump, actuators or linkage.

E10

ERROR DRAIN VALVE NOT OPEN

Drain valve failed to open; the valve’s position is

 

 

unknown.

E11

ERROR DRAIN VALVE NOT CLOSED

Drain valve failed to close; the valve’s position is

 

 

unknown.

E12

ERROR RETURN VALVE NOT OPEN

Return valve failed to open; the valve’s position is

 

 

unknown.

E13

ERROR RETURN VALVE NOT CLOSED

Return valve failed to close; the valve’s position is

 

 

unknown.

E14

ERROR AIF BOARD

MIB detects AIF missing; AIF board failure

E15

ERROR MIB BOARD

Cooking computer detects MIB connections lost;

 

 

Check software version on each computer. If

 

 

versions are missing, check CAN connections

 

 

between each computer; MIB board failure

E16

ERROR AIF PROBE

AIF RTD reading out of range

E17

ERROR ATO PROBE

ATO RTD reading out of range

E18

Not currently used

 

E19

M3000 CAN TX FULL

Connection between computers lost

E20

INVALID CODE LOCATION

SD card removed during update

E21

FILTER PAD PROCEDURE ERROR

25 hour timer has expired or dirty filter logic has

 

(Change Filter Pad)

activated

E22

OIL IN PAN ERROR

The MIB has reset the oil in pan flag.

E23

CLOGGED DRAIN (Gas)

Vat did not empty during filtration

E24

AIF BOARD OIB FAILED (Gas)

Oil is back sensor failed.

E25

RECOVERY FAULT

Recovery time exceeded maximum time limit.

E26

RECOVERY FAULT CALL SERVICE

Recovery time exceeded maximum time limit for

 

 

two or more cycles.

E27

LOW TEMP ALARM

Oil temperature has dropped lower than 15°F (8°C)

 

 

in idle mode or 45°F (25°C) in cook mode.

1-35

Page 42
Image 42
Frymaster BIELA14 manual Error Log Codes, Explanation, 1-35, Error Message