Frymaster BIELA14 Problem, Probable Causes, Corrective Action, 1-14, Service, Required – Ato

Models: BIELA14

1 96
Download 96 pages 23.21 Kb
Page 21
Image 21

Problem

 

Probable Causes

 

Corrective Action

 

 

 

 

A. Ensure JIB has oil.

 

 

 

 

 

B. Check to

see that fryer is heating.

 

 

 

 

Fryer temperature must be at setpoint.

 

 

 

 

Check probe resistance. If probe is

 

 

 

 

bad, replace the probe.

 

 

 

A. Empty JIB.

C. Ensure that the oil in the JIB is above

 

 

 

 

70°F (21°C).

 

 

 

 

B. Probe temperature lower than setpoint.

D. With the computer OFF, press TEMP

 

 

 

 

button and ensure the ATO software

 

C. Oil is too cold.

 

version appears. If not, the connection

 

 

 

 

between the AIF and the ATO board

 

D. Bad Connection

 

may be bad.

Ensure the 6-pin CAN

 

 

connectors are tight between AIF (J4

 

 

 

 

 

E. ATO board power loss

 

and J5) and ATO (J10) boards.

 

Frypots won’t top off.

E. Power to the ATO board has been cut

 

 

F.

 

 

off.

Restore power to

the board and

 

Failed transformer/harness

 

 

 

clear any service required errors.

 

 

 

 

F.

 

 

G. ATO pump failed

Ensure transformer in ATO box is

 

 

functioning

properly.

Check

power

 

H. Failed ATO board.

 

from transformer to ATO board.

 

 

Ensure all harnesses are plugged

 

I.

ATO lines/pump plugged

 

securely into place.

 

 

 

G. Ensure pump

is operational.

Check

 

 

 

 

voltage to pump. Replace the pump if

 

 

 

 

defective.

 

 

 

 

 

 

 

H. Check for proper voltages using the pin

 

 

 

 

position chart found on page 1-15. If

 

 

 

 

ATO found defective, replace ATO

 

 

 

I.

board and clear any errors.

 

 

 

 

Clear the lines/pump.

 

 

 

 

 

A. Clear

filter

error properly.

When

 

 

 

 

change filter pad YES/NO is displayed,

 

A. Filter error exists.

 

do NOT press any button until the pan

 

 

has been removed for at least thirty

One vat doesn’t top off.

 

 

 

B. Actuator, pump, loose connection, RTD

 

seconds.

After thirty

seconds have

 

 

or ATO issue.

 

elapsed, the computer returns to OFF or

 

 

 

last display.

 

 

 

 

 

 

 

 

 

 

 

 

 

B. Check actuator, ATO pump, wire

 

 

 

 

connections, RTD and ATO board.

 

 

 

A. Ensure fuse on right side of ATO box is

 

 

 

 

secure and good. If the computer

 

 

 

 

above the ATO box is missing power

 

 

 

 

check the fuse below the component

 

 

 

 

box.

 

 

 

 

 

 

 

 

B. With the computer OFF, press TEMP

M3000 displays

A. Loose or bad fuse

 

button and ensure the ATO software

 

version appears. If not, the connection

SERVICE

B. Bad Connection

 

between the AIF and the ATO board

REQUIRED ATO

 

BOARD

C. ATO Board power loss

 

may be bad.

Ensure the 6-pin CAN

 

 

 

 

connectors are tight between AIF (J4

 

 

 

 

and J5) and ATO (J9 or J10) boards.

 

 

 

C. Power to the ATO board has been cut

 

 

 

 

off. Ensure there is correct voltage to

 

 

 

 

the ATO transformer. Restore power to

 

 

 

 

the board and clear any service required

 

 

 

 

errors.

 

 

 

 

1-14

Page 21
Image 21
Frymaster BIELA14 manual Problem, Probable Causes, Corrective Action, 1-14, Service, Required – Ato, Board