MAINTENANCE AND SERVICE

MAINTENANCE AND SERVICE

PLEASE NOTE

It is normal for appliances fabricated of steel to give off some expansion and/or contraction noise during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine.

It is not unusual for your gas fireplace to give off some odor the first time it is burned. This is due to the curing of the paint and any undetected oil from the manufacturing process.

Please ensure that your room is well ventilated - open all windows.

It is recommended that you burn your fireplace for at least six

(6)hours the first time you use it. If optional fan kit has been installed, place fan in the “OFF” position during this time.

IMPORTANT: Turn off gas before servicing appliance. It is recommended that a qualified service person perform these check-ups at the beginning of each heating season.

Clean Burner and Control Compartment

Keepthecontrolcompartment,logs,andburnerareassurrounding the logs clean by vacuuming or brushing at least twice a year.

Cleaning Procedure

1.Turn off pilot light at gas valve.

2.Vacuum burner compartment.

3.Ignite pilot (if applicable). (See Lighting Instructions)

4.Operate the pilot burner (if applicable). If it appears abnormal call a service person.

Check Vent System

The appliance and venting system should be inspected before initial use and at least annually by a qualified service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the air flow.

Glass Cleaning (Optional Kits)

It will be necessary to clean the glass periodically. During start-up condensation, which is normal, forms on the inside of the glass and causes lint, dust and other airborne particles to cling to the glass surface. Also initial paint curing may deposit a slight film on the glass. It is therefore recommended that the glass be cleaned two or three times with a non-abrasive household cleaner and warm water (we recommend gas fireplace glass cleaner). After that the glass should be cleaned two or three times during each heating season depending on the circumstances present.

General Glass Information

Only glass approved for use by the manufacturer may be used for replacement. The glass replacement should be done by a licensed or qualified service person.

WARNING:

1.The use of substitute glass will void all product warranties.

2.Care must be taken to avoid breakage of glass.

3.Do not abuse the glass by striking or hitting the glass.

WARNING: Do not use abrasive cleaners on glass. Do not attempt to clean glass when glass is hot.

19400-3-0406

Page 27

Image 27
Contents B-VENT GAS FIREPLACE The Keystone B Vent Zero Clearance Gas FireplaceEFFECTIVE DATE APRIL Section TABLE OF CONTENTSIMPORTANT SAFETY INFORMATION NO ODOR DETECTED - ODOR FADE SAFETY INFORMATION FOR USERS OF LP GASThat’s your signal to go into immediate action LP-GASWARNING ODORAppliance Certification INTRODUCTIONInstructions to Installer Qualified Installing AgencyBVD36 SPECIFICATIONSFIREPLACE DIMENSIONS Dim BVD34Figure Combustible Material CLEARANCESLOCATING FIREPLACE Mantel Chart FigureInstalling a New Main Gas Cock GAS SUPPLYChecking Manifold Pressures GAS SUPPLY CONTFigure Vent Pipe Clearance INSTALLATIONInstall the Fresh Air Kit - BVA1 Framing and FinishingINSTALLATION CONT Combustible Surround InstallationFinishing Figure Vent Runs VENTINGGeneral Maintenance Installing the Vent System in a ChaseVent Configuration VENTING CONTVent Size Never downsize venting diameters ClearancesEMBER MATERIAL PLACEMENT ON BURNER LOG PLACEMENT 5 LOG SETTOP BRANCH REAR LOG BOTTOM LOG LOG PLACEMENT 3 LOG SETEMBER PLACEMENT BOTTOM LOG LOCATOR PINSInitial Lighting OPERATING INSTRUCTIONSGAS CONTROL KNOB SHOWN IN OFF POSITION 750 Millivolt SystemElectric 120 volt Operated Remote Control, FREC OPERATING INSTRUCTIONS CONTWall Switch, FWS-1optional FRBC Battery Operated Remote ControlSTANDING PILOT WIRING DIAGRAM TO TURN OFF GAS TO FIREPLACE FOR YOUR SAFETY, READ BEFORE LIGHTINGSTANDING PILOT LIGHTING INSTRUCTIONS LIGHTING INSTRUCTIONSSTANDING PILOT TROUBLESHOOTING 4.Frequent pilot outage problem6.Glass Sooting B-VENTFIREPLACES STANDING PILOT PROPANE/LP GAS CONVERSIONCHECK SAFETY SHUTDOWN PERFORMANCE SAFETY SHUTDOWN SYSTEMPILOT ORIFICE CONVERSION OPTIONAL REMOTE CONTROL 120V DIRECT IGNITION DIRECT IGNITION WIRING DIAGRAMTO TURN OFF GAS TO APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTINGDIRECT IGNITION LIGHTING INSTRUCTIONS LIGHTING INSTRUCTIONSDIRECT IGNITION PROPANE/LP GAS CONVERSION DIRECT IGNITION TROUBLESHOOTINGDIRECT IGNITION PROPANE/LP GAS CONVERSION Maxitrol Valve ConversionVALVE CONVERSION Glass Cleaning Optional Kits MAINTENANCE AND SERVICEClean Burner and Control Compartment Cleaning ProcedureBVD34 & BVD36 PARTS LIST BVD34 & BVD36 PARTS VIEW 19400-3-0406Page BVP42 PARTS LIST BVP42 PARTS VIEW 19400-3-0406Page FBB4 OPTIONAL VARIABLE SPEED BLOWER INSTALLATION 110 VOLT AC FBB4 OPTIONAL VARIABLE SPEED BLOWER INSTALLATIONJUNCTION BOX FAN BLACK FAN SWITCH WHITE GROUND BLOWER ASSEMBLYJUNCTION BOX WIRING INSTALLATION INSTRUCTIONS STANDARD MILLIVOLT VALVE MODELS120V DIRECT IGNITION VALVE MODELS OPTIONAL ACCESSORIES Decorative Louver Mission DECORATIVE ACCESSORIESPage 19400-0-1005SERVICE NOTES HOW TO ORDER REPAIR PARTS SERVICE NOTES Page19400-3-0406 SERVICE NOTES 19400-3-0406Page Empire Comfort Systems, Inc Page19400-3-0406