STANDING PILOT LIGHTING INSTRUCTIONS
FOR YOUR SAFETY, READ BEFORE LIGHTING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE
A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
•Do not try to light any appliance
•Do not touch any electric switch.
•Do not use any phone in your building.
•Immediately call your gas supplier from a neighbor's phone.
•Follow the gas supplier's instructions.
•If you can not reach your gas supplier, call the fire department.
C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repairit, call a qualified service technician. Force or attempted repair may result in a fire or explosion.
D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
LIGHTING INSTRUCTIONS
1. | STOP! Read the safety information above. | to "PILOT." | |
2. | Set wall switch or remote to "OFF." |
| 9. Push in control knob all the way and hold in. Repeatedly |
3. | Turn off all electric power to the appliance (if | push the Piezo Ignitor Button until the pilot is lit. Continue | |
| applicable). |
| to hold the control knob in for about one (1) minute after |
4. | Open bottom louver assembly, or open valve access | the pilot is lit. Release knob, and it will pop back up. Pilot | |
| door. |
| should remain lit. If it goes out, repeat steps 5 through 9. |
5. | Push in gas control knob slightly | T O L I P | • If knob does not pop up when released, STOP and |
| |||
| and turn clockwise to | IN | IMMEDIATELY call a qualified service technician or |
| "OFF." | gas supplier. | |
| NOTE: Knob cannot be turned | VEN T | • If the pilot will not stay lit after several tries, turn the gas |
| from "PILOT" to "OFF" unless |
| control knob to "OFF" and call your service technician |
| knob is pushed in slightly. Do not | GAS CONTROL KNOB | or gas supplier. |
| force. | SHOWN IN "OFF" POSITION. | 10. Turn gas control knob counterclockwise to "ON." |
6. | Wait ten (10) minutes to clearout |
| 11. Close bottom louver assembly, or close valve access door. |
| any gas. Then smell for gas, including | ELECTRODE | 12. Turn on all electric power to the appliance (if appli- |
| THERMOPILE | ||
| near the floor. If you smell gas, STOP! | PILOT | cable). |
| Follow "B" in the safety information |
| 13. Set wall switch or remote to "ON." |
| on reverse. If you do not smell gas, go |
|
|
| to the next step. |
|
|
7.Find pilot - Follow metal tube from gas control. The pilot is behind the burner on the right side.
8.Turn gas control knob counterclockwise
TO TURN OFF GAS TO FIREPLACE
1.Set wall switch or remote to "OFF."
2.Turn off all electric power to the appliance if service is to be performed (if applicable).
3.Open bottom louver assembly, or open valve access door.
4.Push in gas control knob slightly and turn clockwise to "OFF." Do not force.
5.Close bottom louver assembly, or close valve access door.
Page 19 |