Troubleshooting (cont.)

Troubleshooting Table

Symptoms

Probable Cause

Recommended Action

 

C.

Pressure difference greater than

C.

Install pressure regulators to bring

 

 

5 psi (34.5 kPa) between the hot

 

the supplies with 5 psi (34.5 kPa)

 

 

and cold supply lines.

 

of each other.

 

D. If none of the recommended

D. Contact your Kohler Co. authorized

 

 

actions for the above issues

 

service representative.

 

 

correct the symptom, the valve

 

 

 

 

requires servicing.

 

 

10. Water leaking from the

A.

Connections are not secure.

A.

Check all connections. Make

valve.

 

 

 

adjustments as needed.

CAUTION: Risk of

B.

Seals are worn or damaged.

B.

Order a seal service pack and

personal injury or

 

 

 

replace all seals.

product damage. Turn off

C.

Internal leak.

C.

Unit requires overhaul. Contact

the main power and

 

 

 

your Kohler Co. authorized service

water supply.

 

 

 

 

 

 

representative.

 

 

 

 

11. Hot water only, the valve

A.

Hot and cold lines are reversed.

A.

Switch hot and cold water supply

shuts down.

 

 

 

connections. Verify the hot water

 

 

 

 

supply is connected to the inlet

 

 

 

 

marked ″H″ and the cold water

 

 

 

 

supply is connected to the inlet

 

 

 

 

marked ″C.″

 

 

 

 

 

1043184-2-B

12

Kohler Co.

Image 12
Contents Installation Guide Digital InterfaceIMPORTANT INSTRUCTIONS SpecificationsThank You For Choosing Kohler Company Tools and MaterialsPlus Roughing-In Before You Begin 1/2 1.3 cm Min Clamp Arm ClearanceClamp Arm Cutout1. Preparation 2. Prepare the Site Cutout Interface lip 1/4 6 mm7-11/16 19.5 cm 3-11/16 9.4 cm 52 132.1 cm3. Install the Interface Install the Interface cont 1043184-2-BKohler Co 4. Complete the Installation 5. Installation CheckoutKohler Co 1043184-2-B6. Troubleshooting Installation Checkout contTroubleshooting cont Troubleshooting TableTroubleshooting cont Troubleshooting TableGuide d’installation Renseignements importantsInterface digitale SpécificationsMerci d’avoir choisi la compagnie Kohler Outils et matérielsPlus Raccordement Avant de commencer Dégagement minimum du bras de la pince 1/2 1,3 cmDécoupe Bras de la pince1. Préparation 2. Préparer le site Lèvre delinterface 1/4 6 mm3. Installer l’interface Anneau45,7 cm découlementInstaller l’interface cont Kohler CoFrançais-7 1043184-2-B4. Compléter l’installation 5. Vérification de l’installation1043184-2-B Français-8Vérification de l’installation cont 6. DépannageDépannage cont 1043184-2-BFrançais-10 Kohler CoDépannage cont Tableau de dépannageGuía de instalación INSTRUCCIONES IMPORTANTESInterface digital EspecificacionesGracias por elegir los productos de Kohler Herramientas y materialesDiagrama de instalación Antes de comenzar Brazo de abrazaderaAbertura Espacio para el1. Preparación 2. Prepare el sitio Labio de lainterface Abertura3. Instale la interface 45,7 cmLazo de goteo Kohler CoInstale la interface cont 1043184-2-BEspañol-7 Kohler Co4. Termine la instalación 5. Verificación de la instalaciónKohler Co Español-86. Procedimiento para resolver problemas Verificación de la instalación contProcedimiento para resolver problemas cont Kohler CoEspañol-10 1043184-2-BProcedimiento para resolver problemas cont Tabla para resolver problemas1043184-2-B 2006 Kohler Co