Troubleshooting (cont.)
Troubleshooting Table
Symptoms | Probable Cause | Recommended Action | |||
| C. | Pressure difference greater than | C. | Install pressure regulators to bring | |
|
| 5 psi (34.5 kPa) between the hot |
| the supplies with 5 psi (34.5 kPa) | |
|
| and cold supply lines. |
| of each other. | |
| D. If none of the recommended | D. Contact your Kohler Co. authorized | |||
|
| actions for the above issues |
| service representative. | |
|
| correct the symptom, the valve |
|
| |
|
| requires servicing. |
|
| |
10. Water leaking from the | A. | Connections are not secure. | A. | Check all connections. Make | |
valve. |
|
|
| adjustments as needed. | |
CAUTION: Risk of | B. | Seals are worn or damaged. | B. | Order a seal service pack and | |
personal injury or |
|
|
| replace all seals. | |
product damage. Turn off | C. | Internal leak. | C. | Unit requires overhaul. Contact | |
the main power and | |||||
|
|
| your Kohler Co. authorized service | ||
water supply. |
|
|
| ||
|
|
| representative. | ||
|
|
|
| ||
11. Hot water only, the valve | A. | Hot and cold lines are reversed. | A. | Switch hot and cold water supply | |
shuts down. |
|
|
| connections. Verify the hot water | |
|
|
|
| supply is connected to the inlet | |
|
|
|
| marked ″H″ and the cold water | |
|
|
|
| supply is connected to the inlet | |
|
|
|
| marked ″C.″ | |
|
|
|
|
|
12 | Kohler Co. |