Samsung AF55JS1MAAPNMG, AF55JV1MAAPNMG Drilling a hole in a wall, Space requirements, ENGLISH-45

Page 45

Preparing the installation

• After installing the outdoor unit, apply rust inhibitor on the internal pipes and heat exchanger.

WARNING

-- If you don’t apply rust inhibitor, airborne corrosive gas (such as sulfur compounds, hydrogen sulfide and

ammonia) and salty dust may cause pipe corrosion which will lead to refrigerant leakage.

 

 

-- Inspect the outdoor unit at least once a year and re-apply the rust inhibitor where it is damaged (worn out).

When applying the rust inhibitor, please be aware of the following: -- Turn off the power before spraying the rust inhibitor.

-- Wear protective goggles and mask before spraying.

-- Clean the dusty surface with clean fabric or paper before spraying. -- Make sure that wind is blowing from worker’s back when spraying. -- Do not spray on the PCB panel and electric parts.

Install the indoor unit away from any interfering sources such as radio, computer, stereo equipment and also

I06nstallation

CAUTION

select the place where the electrical wiring work can be possible.

-- Especially keep the unit at least 3m away from the electrical equipment in an area electromagnetic waves generated and install the protection tube to protect the main power cable and communication cable.

-- Make sure that there is no equipment electromagnetic waves generate. If not, malfunction of the control system may occur due to the effect of the electromagnetic wave. (For example: The remote control sensor of the indoor unit may not be received well of electronic lighting style fluorescent lamps, such as fluorescent lamps are in the same space when using a remote control.)

Make sure to install the outdoor unit in a safe place where snowfall will not be obstructed. The frame should be installed in a place where the air inlet and heat exchanger of the unit are not buried in the snow.

A ventilation system may be required in the case the outdoor unit is installed in a closed space or room, even though R-410A is not poisonous or flammable.

Install the railing around the outdoor unit to prevent falling when the unit is installed at high place of roof on the building.

Avoid installing the units in places such as an exhaust pipe and ventilating opening exposed to corrosive gas, oxides of sulfur, ammonia gas or sulfur gas herbicides. (These places need additional anticorrosive treatments. Please contact manufacture to avoid corroding copper pipes or soldered parts)

Depending on the condition of power supply, unstable power or voltage may cause malfunction of the parts or control system. (At the ship or places using power supply from electric generator, etc)

Drilling a hole in a wall

 

ffDrill a hole at a slightly downward slant (15˚) with a diameter of 60~65 mm.

Outdoor

Indoor

Ø60~65 mm

 

Space requirements

ffThe space suggested below is based on operating condition of outdoor temperature of 35 °C. If operating condition of outdoor temperature is higher than 35 °C, try to have more space.

ffMake sure to clear a passage for a person and air flow.

ffObserve the clearances and dimensions as seen below when installing the outdoor unit.

fIfyou install several outdoor units at the same place, observe the space for ventilation and free airflow.

fIfthe space for ventilation is insufficient, the air conditioner may not generate performance designed. Keep in mind that SAMSUNG logo is located on the front side of outdoor unit.

ENGLISH-45

PAC MIRAGE Saudi_IBIM_EN_CS6_DB68-04872A-05.indd 45

2016-08-08 오전 11:38:33

Image 45
Contents Thank you for purchasing this Samsung product Air ConditionerPowerful speed/Convenient remote operation Features of your new air conditionerEnergy saving technology with S-inverter system Auto air flow bladesContents ENGLISH-4 Safety precautionsP01reparation ENGLISH-5ENGLISH-6 For InstallationENGLISH-7 For Power Supply WarningENGLISH-8 ENGLISH-9 ENGLISH-10 ENGLISH-11 FfThis may result in property damageENGLISH-12 Do not clean the inside of the air conditioner by yourselfENGLISH-13 Checking before useOperational temperature and humidity range Checking auxiliary power switchAuxiliary power switchELCB, ELB Mode Indoor temperature Outdoor temperature Indoor humidityMain parts Checking the name of the partsENGLISH-15 To open the panelENGLISH-16 Control panel and the displayChecking the remote controller Remote controller buttonsENGLISH-17 ENGLISH-18 Remote controller displayBattery changing time Using the remote controllerStoring the remote controller Inserting the batteriesENGLISH-20 Basic operationSelecting the operation mode Turning on the powerAdjusting the desired temperature Selecting the fan speedENGLISH-22 Selecting air flow directionWhen the air conditioner is off Setting the On/Off timerAdditional options available in On timer ENGLISH-23ENGLISH-24 When the air conditioner is onUsing the Turbo function When the air conditioner is operating in Cool or Heat modeENGLISH-25 ENGLISH-26 Using the Long functionLocking the control panel ENGLISH-27O04 thers Button to adjust vertical air flow direction Using the air conditioner with the control panelENGLISH-28 Button againCleaning the outdoor unit heat exchanger Cleaning the indoor unitENGLISH-29 O05 thersENGLISH-30 Cleaning the Air filterPeriodical checks Maintaining your air conditionerENGLISH-31 Dust, etcInternal protections via the unit control system May have deposited at low temperaturesENGLISH-32 Type DescriptionENGLISH-33 TroubleshootingENGLISH-34 Come out of the air Turned on ConditionerENGLISH-35 Generate any odorENGLISH-36 Noise is generatedGeneral information Accessing its internal componentsENGLISH-37 I06nstallationPower supply line, fuse or circuit breaker Installing the unitDo not install the air conditioner in following places ENGLISH-38Accessory parts list ENGLISH-39Part Name Indoor unit Selection of installation placeSide view Outdoor unitWhen the air outlet is opposite the wall Single installationWhen 3 sides of the outdoor unit are blocked by the wall ENGLISH-41ENGLISH-42 When installing more than 1 outdoor unitENGLISH-43 Outdoor unit base mount and anchor bolt positionPreparing the installation Selecting appropriate location for installationENGLISH-44 Space requirements Drilling a hole in a wallENGLISH-45 Wear protective goggles and mask before sprayingRefrigerant pipe work Insulating the pipes Installing the air conditionerOil trap ENGLISH-46Electrical work Refrigerant piping workENGLISH-47 Removing the connection pipeENGLISH-48 Power specificationConnecting the power terminal ENGLISH-49Or capacity requirements Connecting the wires ENGLISH-50AF55J1MA Series / Ackpcc Series FfPower wiring diagram FfEntire system diagramOrder of electrical connection ENGLISH-51FfIndoor and outdoor unit connection diagram FfEntire system diagram Power supply cableENGLISH-52 AF55J3MA SeriesENGLISH-53 How to connect your extended power cablesPrepare the following tools Contraction tubeENGLISH-54 FfMethodApply heat to the contraction tube to contract it ENGLISH-55 Checking the earthingENGLISH-56 Charging the refrigerant and preventing refrigerant leakage ENGLISH-57Nm = 10 kgfcm Pressure table for temperatures Indoor temperature C Dry bulb / Wet bulbENGLISH-58 FfFix the pipe with a clamp and screws ENGLISH-59Connecting drain hose of indoor and outdoor unit ENGLISH-60Fix them with a cable tie or tape ENGLISH-61 Things to check after completing the installationFf3 phases power supply R, S, T, N Testing operationsENGLISH-62 Check the indoor unitENGLISH-63 Short Display contentsUnit PushFfDIP switchSW507 option DIP switch optionFor 4 indoor unit connection FfDIP switchSW508 option ENGLISH-64Meaning Remarks ENGLISH-65After pipe extension ENGLISH-66ENGLISH-67 Packing and unpacking guideENGLISH-68 ENGLISH-69 Product specificationENGLISH-70 Design Pressure ENGLISH-71Questions or COMMENTS?
Related manuals
Manual 72 pages 59.62 Kb

AF55JV1MAEENMG, AF55JV1MAAPNMG, AF55JV3MAEENMG, AF55JS1MAEENMG, AF55JS1MAAPNMG specifications

The Samsung AF55JS3MAAPNMG, AF55MV1MAEENMG, AF55JV1MAEEXMG, AF55JV3MAAPNMG, and AF55JS3MAEENMG series of displays represent the pinnacle of modern digital signage technology. These models are designed for a variety of commercial applications, ranging from retail environments to corporate settings, providing a comprehensive solution for any visual communication need.

One of the standout features of these displays is their impressive picture quality. Equipped with Samsung's advanced LED technology, these monitors deliver vibrant colors, deep blacks, and excellent contrast ratios. This ensures that content is not only visually appealing but also easy to read, making it ideal for advertising and information dissemination.

The AF series incorporates Smart Hub technology, which allows for seamless access to various applications and content management systems. This feature streamlines the process of displaying digital signage content, enabling users to easily update and manage their information from a centralized location. The integration of this technology enhances the overall user experience and simplifies operations within retail and corporate environments.

These displays also boast a wide viewing angle, which ensures that content is visible from multiple perspectives. This is particularly advantageous in high-traffic areas where customers or employees may be viewing the screen from different locations. The result is enhanced engagement and improved communication, which are essential for effective digital signage.

In terms of durability, the AF55 series is built to withstand the rigors of continuous operation. The models are designed for 24/7 usage, making them ideal for environments that require round-the-clock operation. Their robust construction ensures reliability and longevity, providing businesses with a sound investment over time.

Additionally, energy efficiency is a key characteristic of the Samsung AF55 displays. These models are designed to consume less power without compromising on performance, contributing to lower operational costs and a reduced environmental impact.

Moreover, the flexibility in installation is another notable feature. These displays can be mounted in various orientations, including landscape and portrait modes, allowing businesses to customize their setup based on the space available and the nature of the content being displayed.

In summary, the Samsung AF55 series models are equipped with advanced technologies, superior picture quality, and solid durability. Their flexible application, energy efficiency, and user-friendly management features make them a top choice for businesses looking to leverage digital signage effectively.