Samsung AF55JS1MAAPNMG, AF55JV1MAAPNMG, AF55MV1MAEENMG, AF55JS1MAEENMG ENGLISH-5, P01reparation

Page 5

FOR INSTALLATION WARNING

Use the power line with the power specifications of the product or higher and use the power line for this appliance only. In addition, do not use an extension line.

ffExtending the power line may result in electric shock or fire. ffDo not use an electric transformer. It may result in electric shock

or fire.

fIfthe voltage/frequency/rated current condition is different, it may cause fire.

The installation of this appliance must be performed by a qualified technician or service company.

ffFailing to do so may result in electric shock, fire, explosion, problems with the product, or injury.

Install a switch and circuit breaker dedicated to the air conditioner.

ffFailing to do so may result in electric shock or fire.

Fix the outdoor unit firmly so that the electric part of the outdoor unit is not exposed.

ffFailing to do so may result in electric shock or fire.

Do not install this appliance near a heater, inflammable material. Do not install this appliance in a humid, oily or dusty location, in a location exposed to direct sunlight and water (rain drops). Do not install this appliance in a location where gas may leak.

ffThis may result in electric shock or fire.

Never install the outdoor unit in a location such as on a high external wall where it could fall.

fIfthe outdoor unit falls, it may result in injury, death or property damage.

P01reparation

ENGLISH-5

PAC MIRAGE Saudi_IBIM_EN_CS6_DB68-04872A-05.indd 5

2016-08-08 오전 11:38:17

Image 5 Contents
Thank you for purchasing this Samsung product Air ConditionerPowerful speed/Convenient remote operation Features of your new air conditionerEnergy saving technology with S-inverter system Auto air flow bladesContents ENGLISH-4 Safety precautionsP01reparation ENGLISH-5ENGLISH-6 For InstallationENGLISH-7 For Power Supply WarningENGLISH-8 ENGLISH-9 ENGLISH-10 ENGLISH-11 FfThis may result in property damageENGLISH-12 Do not clean the inside of the air conditioner by yourselfENGLISH-13 Checking before useOperational temperature and humidity range Checking auxiliary power switchAuxiliary power switchELCB, ELB Mode Indoor temperature Outdoor temperature Indoor humidityMain parts Checking the name of the partsENGLISH-15 To open the panelENGLISH-16 Control panel and the displayENGLISH-17 Checking the remote controllerRemote controller buttons ENGLISH-18 Remote controller displayBattery changing time Using the remote controllerStoring the remote controller Inserting the batteriesENGLISH-20 Basic operationSelecting the operation mode Turning on the powerAdjusting the desired temperature Selecting the fan speedENGLISH-22 Selecting air flow directionWhen the air conditioner is off Setting the On/Off timerAdditional options available in On timer ENGLISH-23ENGLISH-24 When the air conditioner is onENGLISH-25 Using the Turbo functionWhen the air conditioner is operating in Cool or Heat mode ENGLISH-26 Using the Long functionO04 thers Locking the control panelENGLISH-27 Button to adjust vertical air flow direction Using the air conditioner with the control panelENGLISH-28 Button againCleaning the outdoor unit heat exchanger Cleaning the indoor unitENGLISH-29 O05 thersENGLISH-30 Cleaning the Air filterPeriodical checks Maintaining your air conditionerENGLISH-31 Dust, etcInternal protections via the unit control system May have deposited at low temperaturesENGLISH-32 Type DescriptionENGLISH-33 TroubleshootingENGLISH-34 Come out of the air Turned on ConditionerENGLISH-35 Generate any odorENGLISH-36 Noise is generatedGeneral information Accessing its internal componentsENGLISH-37 I06nstallationPower supply line, fuse or circuit breaker Installing the unitDo not install the air conditioner in following places ENGLISH-38Part Name Accessory parts listENGLISH-39 Indoor unit Selection of installation placeSide view Outdoor unitWhen the air outlet is opposite the wall Single installationWhen 3 sides of the outdoor unit are blocked by the wall ENGLISH-41ENGLISH-42 When installing more than 1 outdoor unitENGLISH-43 Outdoor unit base mount and anchor bolt positionENGLISH-44 Preparing the installationSelecting appropriate location for installation Space requirements Drilling a hole in a wallENGLISH-45 Wear protective goggles and mask before sprayingRefrigerant pipe work Insulating the pipes Installing the air conditionerOil trap ENGLISH-46Electrical work Refrigerant piping workENGLISH-47 Removing the connection pipeENGLISH-48 Power specificationOr capacity requirements Connecting the power terminalENGLISH-49 AF55J1MA Series / Ackpcc Series Connecting the wiresENGLISH-50 FfPower wiring diagram FfEntire system diagramOrder of electrical connection ENGLISH-51FfIndoor and outdoor unit connection diagram FfEntire system diagram Power supply cableENGLISH-52 AF55J3MA SeriesENGLISH-53 How to connect your extended power cablesPrepare the following tools Contraction tubeApply heat to the contraction tube to contract it ENGLISH-54FfMethod ENGLISH-55 Checking the earthingENGLISH-56 Nm = 10 kgfcm Charging the refrigerant and preventing refrigerant leakageENGLISH-57 ENGLISH-58 Pressure table for temperaturesIndoor temperature C Dry bulb / Wet bulb FfFix the pipe with a clamp and screws ENGLISH-59Fix them with a cable tie or tape Connecting drain hose of indoor and outdoor unitENGLISH-60 ENGLISH-61 Things to check after completing the installationFf3 phases power supply R, S, T, N Testing operationsENGLISH-62 Check the indoor unitENGLISH-63 Short Display contentsUnit PushFfDIP switchSW507 option DIP switch optionFor 4 indoor unit connection FfDIP switchSW508 option ENGLISH-64Meaning Remarks ENGLISH-65After pipe extension ENGLISH-66ENGLISH-67 Packing and unpacking guideENGLISH-68 ENGLISH-69 Product specificationENGLISH-70 Design Pressure ENGLISH-71Questions or COMMENTS?