Samsung AF55JV1MAEEXMG Installing the air conditioner, Refrigerant pipe work Insulating the pipes

Page 46

Installing the air conditioner

Refrigerant pipe work

Insulating the pipes

ffMake sure to insulated the refrigerant pipes with an insulation tape. If the pipe is not insulated, condensate may form and drop into the indoor.

ffWind the refrigerant pipes and the drain hose with vinyl tapes.

ffWhen you bend the pipe, try to secure large bending radius (over 100 mm) to prevent the copper pipe from distorting.

ffUse foamed polyethylene or EPDM foam, with thickness over 7 mm, as an insulator.

fIfthe pipe is installed in a place with humidity over 80 % (such as within a pit of a building, basement, sea shore, near hot spring or lake etc), use an insulator with a thickness over 10 mm.

Pipe insulator

 

Vinyl

Indoor/

tape

 

outdoor unit

 

communication

 

cable

 

 

Drain hose

ffInsulate the high pressure (liquid pipe)/low pressure (gas pipe) pipe, and finish it by winding up the vinyl tape around it.

ffMake sure to insulate the pipe with no gap or cracks, and use adhesive between the connection part of the insulator to prevent moisture from entering.

ffMake sure that the thickness of the insulator doesn’t get thinner on the bending part of the pipes. ffUse extra insulator to secure thickness when the insulator becomes thinner.

ffWhen the pipe hanger is installed, wind the extra PE Foam type insulator (over 5 mm) with the width 3 times wider than the hanger. (Do not use cable tie as an hanger.)

Oil trap

Check the following list and install an oil trap.

ffInstall an oil trap only when the outdoor unit is at a higher level than the indoor unit. ffBased on cooling operation, install it on the gas side pipe only.

ffInstall the oil trap only in between the outdoor unit and the first branch joint and it should be installed at every 10 m. ffRadius of curvature (R) on the oil trap are as follows:

 

(Unit: mm)

 

 

Pipe diameter (D)

Radius of curvature (R)

12.70

25 and over

15.88

32 and over

19.05

38 and over

22.23

41 and over

25.40

51 and over

 

 

28.60

57 and over

 

 

31.75

60 and over

 

 

ffHeight of the oil trap (H): 4R ≤ H ≤ 6R

Outdoor unit

Oil trap

 

(Gas side pipe: Install

Insulation

it at every 10 m)

 

Branch joint

Cut on insulation

 

Indoor unit

ENGLISH-46

PAC MIRAGE Saudi_IBIM_EN_CS6_DB68-04872A-05.indd 46

2016-08-08 오전 11:38:33

Image 46
Contents Air Conditioner Thank you for purchasing this Samsung productEnergy saving technology with S-inverter system Features of your new air conditionerPowerful speed/Convenient remote operation Auto air flow bladesContents Safety precautions ENGLISH-4ENGLISH-5 P01reparationFor Installation ENGLISH-6For Power Supply Warning ENGLISH-7ENGLISH-8 ENGLISH-9 ENGLISH-10 FfThis may result in property damage ENGLISH-11Do not clean the inside of the air conditioner by yourself ENGLISH-12Checking before use ENGLISH-13Auxiliary power switchELCB, ELB Checking auxiliary power switchOperational temperature and humidity range Mode Indoor temperature Outdoor temperature Indoor humidityENGLISH-15 Checking the name of the partsMain parts To open the panelControl panel and the display ENGLISH-16Remote controller buttons Checking the remote controllerENGLISH-17 Remote controller display ENGLISH-18Storing the remote controller Using the remote controllerBattery changing time Inserting the batteriesBasic operation ENGLISH-20Adjusting the desired temperature Turning on the powerSelecting the operation mode Selecting the fan speedSelecting air flow direction ENGLISH-22Additional options available in On timer Setting the On/Off timerWhen the air conditioner is off ENGLISH-23When the air conditioner is on ENGLISH-24When the air conditioner is operating in Cool or Heat mode Using the Turbo functionENGLISH-25 Using the Long function ENGLISH-26ENGLISH-27 Locking the control panelO04 thers ENGLISH-28 Using the air conditioner with the control panelButton to adjust vertical air flow direction Button againENGLISH-29 Cleaning the indoor unitCleaning the outdoor unit heat exchanger O05 thersCleaning the Air filter ENGLISH-30ENGLISH-31 Maintaining your air conditionerPeriodical checks Dust, etcENGLISH-32 May have deposited at low temperaturesInternal protections via the unit control system Type DescriptionTroubleshooting ENGLISH-33Come out of the air Turned on Conditioner ENGLISH-34Generate any odor ENGLISH-35Noise is generated ENGLISH-36ENGLISH-37 Accessing its internal componentsGeneral information I06nstallationDo not install the air conditioner in following places Installing the unitPower supply line, fuse or circuit breaker ENGLISH-38ENGLISH-39 Accessory parts listPart Name Side view Selection of installation placeIndoor unit Outdoor unitWhen 3 sides of the outdoor unit are blocked by the wall Single installationWhen the air outlet is opposite the wall ENGLISH-41When installing more than 1 outdoor unit ENGLISH-42Outdoor unit base mount and anchor bolt position ENGLISH-43Selecting appropriate location for installation Preparing the installationENGLISH-44 ENGLISH-45 Drilling a hole in a wallSpace requirements Wear protective goggles and mask before sprayingOil trap Installing the air conditionerRefrigerant pipe work Insulating the pipes ENGLISH-46ENGLISH-47 Refrigerant piping workElectrical work Removing the connection pipePower specification ENGLISH-48ENGLISH-49 Connecting the power terminalOr capacity requirements ENGLISH-50 Connecting the wiresAF55J1MA Series / Ackpcc Series Order of electrical connection FfEntire system diagramFfPower wiring diagram ENGLISH-51ENGLISH-52 FfEntire system diagram Power supply cableFfIndoor and outdoor unit connection diagram AF55J3MA SeriesPrepare the following tools How to connect your extended power cablesENGLISH-53 Contraction tubeFfMethod ENGLISH-54Apply heat to the contraction tube to contract it Checking the earthing ENGLISH-55ENGLISH-56 ENGLISH-57 Charging the refrigerant and preventing refrigerant leakageNm = 10 kgfcm Indoor temperature C Dry bulb / Wet bulb Pressure table for temperaturesENGLISH-58 ENGLISH-59 FfFix the pipe with a clamp and screwsENGLISH-60 Connecting drain hose of indoor and outdoor unitFix them with a cable tie or tape Things to check after completing the installation ENGLISH-61ENGLISH-62 Testing operationsFf3 phases power supply R, S, T, N Check the indoor unitUnit Short Display contentsENGLISH-63 PushFor 4 indoor unit connection FfDIP switchSW508 option DIP switch optionFfDIP switchSW507 option ENGLISH-64ENGLISH-65 Meaning RemarksENGLISH-66 After pipe extensionPacking and unpacking guide ENGLISH-67ENGLISH-68 Product specification ENGLISH-69ENGLISH-70 ENGLISH-71 Design PressureQuestions or COMMENTS?
Related manuals
Manual 72 pages 59.62 Kb

AF55JV1MAEENMG, AF55JV1MAAPNMG, AF55JV3MAEENMG, AF55JS1MAEENMG, AF55JS1MAAPNMG specifications

The Samsung AF55JS3MAAPNMG, AF55MV1MAEENMG, AF55JV1MAEEXMG, AF55JV3MAAPNMG, and AF55JS3MAEENMG series of displays represent the pinnacle of modern digital signage technology. These models are designed for a variety of commercial applications, ranging from retail environments to corporate settings, providing a comprehensive solution for any visual communication need.

One of the standout features of these displays is their impressive picture quality. Equipped with Samsung's advanced LED technology, these monitors deliver vibrant colors, deep blacks, and excellent contrast ratios. This ensures that content is not only visually appealing but also easy to read, making it ideal for advertising and information dissemination.

The AF series incorporates Smart Hub technology, which allows for seamless access to various applications and content management systems. This feature streamlines the process of displaying digital signage content, enabling users to easily update and manage their information from a centralized location. The integration of this technology enhances the overall user experience and simplifies operations within retail and corporate environments.

These displays also boast a wide viewing angle, which ensures that content is visible from multiple perspectives. This is particularly advantageous in high-traffic areas where customers or employees may be viewing the screen from different locations. The result is enhanced engagement and improved communication, which are essential for effective digital signage.

In terms of durability, the AF55 series is built to withstand the rigors of continuous operation. The models are designed for 24/7 usage, making them ideal for environments that require round-the-clock operation. Their robust construction ensures reliability and longevity, providing businesses with a sound investment over time.

Additionally, energy efficiency is a key characteristic of the Samsung AF55 displays. These models are designed to consume less power without compromising on performance, contributing to lower operational costs and a reduced environmental impact.

Moreover, the flexibility in installation is another notable feature. These displays can be mounted in various orientations, including landscape and portrait modes, allowing businesses to customize their setup based on the space available and the nature of the content being displayed.

In summary, the Samsung AF55 series models are equipped with advanced technologies, superior picture quality, and solid durability. Their flexible application, energy efficiency, and user-friendly management features make them a top choice for businesses looking to leverage digital signage effectively.