Samsung AF55JV3MAAPNMG manual Connecting the power terminal, ENGLISH-49, Or capacity requirements

Page 49

Installing the air conditioner

 

• Supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed flexible

NOTE

cord. (Code designation IEC:60245 IEC 57 / CENELEC: H05RN-F or IEC:60245 IEC66 / CENELEC H07RN-F)

This equipment complies with IEC 61000-3-12 provided that the short-circuit power Ssc is greater than or equal to Ssc (*2) at the interface point between the user's supply and the public system. It is the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the equipment is connected only to a supply with a short-circuit power Ssc greater than or equal to Ssc(*2). [Ssc (*2)]

MODEL

Ssc[MVA]

AF55JV3MAEEXMG

0.944

AF55JV1MAEEXMG

0.819

• Please use rated wires or products (with heat resistance over 105 °C) of all the wires and the switches or fuses in

CAUTION

the cabinet panel. (Retailer and installer is responsible for the use of parts that does not meet the wire standards

or capacity requirements)

 

Make sure that wires doesn’t make any sparks around the auxiliary power switch or installed in a place with high temperature. (If the ambient temperature is high, allowable current of the wire will decrease and current reduction factor will occur.)

Please install the auxiliary power switch in a dry place and install panel board or electrical component box.

Please install circuit breaker in the panel board.

When connecting the main power, press the wire to the terminal to secure connection.

Selecting crimp-style ring terminal

Silver solder

I06nstallation

Thickness of the wire (mm2)

B (mm)

d2 (mm)

2.5

Less than 9.5

More than 4.5

4

Less than 9.5

More than 4.5

6

Less than 9.5

More than 4.5

10

Less than 15

More than 8.4

Connecting the power terminal

ffConnect the cables to the terminal board with solderless ring terminals.

ffOnly sue the certified and rated cables and make sure to firmly connect them without applying any external force to the terminal.

ffConnect with a driver and a wrench that are able to apply the rated torque to the screws.

ffConnect the terminal screws according to the rated tightening torque. If the terminal is loose, fire can occur due to arc heat generation and if the terminal is too tight, terminal board could get damaged.

Screw

M3

M3.5

M4

M5

M6

Tightening torque for terminal (kgf∙cm)

5.0 ~ 7.5

8.0 ~ 12.0

12 ~ 18

20 ~ 30

25 ~ 37.5

ENGLISH-49

PAC MIRAGE Saudi_IBIM_EN_CS6_DB68-04872A-05.indd 49

2016-08-08 오전 11:38:34

Image 49
Contents Thank you for purchasing this Samsung product Air ConditionerPowerful speed/Convenient remote operation Features of your new air conditionerEnergy saving technology with S-inverter system Auto air flow bladesContents ENGLISH-4 Safety precautionsP01reparation ENGLISH-5ENGLISH-6 For InstallationENGLISH-7 For Power Supply WarningENGLISH-8 ENGLISH-9 ENGLISH-10 ENGLISH-11 FfThis may result in property damageENGLISH-12 Do not clean the inside of the air conditioner by yourselfENGLISH-13 Checking before useOperational temperature and humidity range Checking auxiliary power switchAuxiliary power switchELCB, ELB Mode Indoor temperature Outdoor temperature Indoor humidityMain parts Checking the name of the partsENGLISH-15 To open the panelENGLISH-16 Control panel and the displayRemote controller buttons Checking the remote controllerENGLISH-17 ENGLISH-18 Remote controller displayBattery changing time Using the remote controllerStoring the remote controller Inserting the batteriesENGLISH-20 Basic operationSelecting the operation mode Turning on the powerAdjusting the desired temperature Selecting the fan speedENGLISH-22 Selecting air flow directionWhen the air conditioner is off Setting the On/Off timerAdditional options available in On timer ENGLISH-23ENGLISH-24 When the air conditioner is onWhen the air conditioner is operating in Cool or Heat mode Using the Turbo functionENGLISH-25 ENGLISH-26 Using the Long functionENGLISH-27 Locking the control panelO04 thers Button to adjust vertical air flow direction Using the air conditioner with the control panelENGLISH-28 Button againCleaning the outdoor unit heat exchanger Cleaning the indoor unitENGLISH-29 O05 thersENGLISH-30 Cleaning the Air filterPeriodical checks Maintaining your air conditionerENGLISH-31 Dust, etcInternal protections via the unit control system May have deposited at low temperaturesENGLISH-32 Type DescriptionENGLISH-33 TroubleshootingENGLISH-34 Come out of the air Turned on ConditionerENGLISH-35 Generate any odorENGLISH-36 Noise is generatedGeneral information Accessing its internal componentsENGLISH-37 I06nstallationPower supply line, fuse or circuit breaker Installing the unitDo not install the air conditioner in following places ENGLISH-38ENGLISH-39 Accessory parts listPart Name Indoor unit Selection of installation placeSide view Outdoor unitWhen the air outlet is opposite the wall Single installationWhen 3 sides of the outdoor unit are blocked by the wall ENGLISH-41ENGLISH-42 When installing more than 1 outdoor unitENGLISH-43 Outdoor unit base mount and anchor bolt positionSelecting appropriate location for installation Preparing the installationENGLISH-44 Space requirements Drilling a hole in a wallENGLISH-45 Wear protective goggles and mask before sprayingRefrigerant pipe work Insulating the pipes Installing the air conditionerOil trap ENGLISH-46Electrical work Refrigerant piping workENGLISH-47 Removing the connection pipeENGLISH-48 Power specificationENGLISH-49 Connecting the power terminalOr capacity requirements ENGLISH-50 Connecting the wiresAF55J1MA Series / Ackpcc Series FfPower wiring diagram FfEntire system diagramOrder of electrical connection ENGLISH-51FfIndoor and outdoor unit connection diagram FfEntire system diagram Power supply cableENGLISH-52 AF55J3MA SeriesENGLISH-53 How to connect your extended power cablesPrepare the following tools Contraction tubeFfMethod ENGLISH-54Apply heat to the contraction tube to contract it ENGLISH-55 Checking the earthingENGLISH-56 ENGLISH-57 Charging the refrigerant and preventing refrigerant leakageNm = 10 kgfcm Indoor temperature C Dry bulb / Wet bulb Pressure table for temperaturesENGLISH-58 FfFix the pipe with a clamp and screws ENGLISH-59ENGLISH-60 Connecting drain hose of indoor and outdoor unitFix them with a cable tie or tape ENGLISH-61 Things to check after completing the installationFf3 phases power supply R, S, T, N Testing operationsENGLISH-62 Check the indoor unitENGLISH-63 Short Display contentsUnit PushFfDIP switchSW507 option DIP switch optionFor 4 indoor unit connection FfDIP switchSW508 option ENGLISH-64Meaning Remarks ENGLISH-65After pipe extension ENGLISH-66ENGLISH-67 Packing and unpacking guideENGLISH-68 ENGLISH-69 Product specificationENGLISH-70 Design Pressure ENGLISH-71Questions or COMMENTS?
Related manuals
Manual 72 pages 59.62 Kb

AF55JV1MAEENMG, AF55JV1MAAPNMG, AF55JV3MAEENMG, AF55JS1MAEENMG, AF55JS1MAAPNMG specifications

The Samsung AF55JS3MAAPNMG, AF55MV1MAEENMG, AF55JV1MAEEXMG, AF55JV3MAAPNMG, and AF55JS3MAEENMG series of displays represent the pinnacle of modern digital signage technology. These models are designed for a variety of commercial applications, ranging from retail environments to corporate settings, providing a comprehensive solution for any visual communication need.

One of the standout features of these displays is their impressive picture quality. Equipped with Samsung's advanced LED technology, these monitors deliver vibrant colors, deep blacks, and excellent contrast ratios. This ensures that content is not only visually appealing but also easy to read, making it ideal for advertising and information dissemination.

The AF series incorporates Smart Hub technology, which allows for seamless access to various applications and content management systems. This feature streamlines the process of displaying digital signage content, enabling users to easily update and manage their information from a centralized location. The integration of this technology enhances the overall user experience and simplifies operations within retail and corporate environments.

These displays also boast a wide viewing angle, which ensures that content is visible from multiple perspectives. This is particularly advantageous in high-traffic areas where customers or employees may be viewing the screen from different locations. The result is enhanced engagement and improved communication, which are essential for effective digital signage.

In terms of durability, the AF55 series is built to withstand the rigors of continuous operation. The models are designed for 24/7 usage, making them ideal for environments that require round-the-clock operation. Their robust construction ensures reliability and longevity, providing businesses with a sound investment over time.

Additionally, energy efficiency is a key characteristic of the Samsung AF55 displays. These models are designed to consume less power without compromising on performance, contributing to lower operational costs and a reduced environmental impact.

Moreover, the flexibility in installation is another notable feature. These displays can be mounted in various orientations, including landscape and portrait modes, allowing businesses to customize their setup based on the space available and the nature of the content being displayed.

In summary, the Samsung AF55 series models are equipped with advanced technologies, superior picture quality, and solid durability. Their flexible application, energy efficiency, and user-friendly management features make them a top choice for businesses looking to leverage digital signage effectively.