MODEL

 

AR18NVFHEWK/MG

 

 

AR18NSFHEWK/MG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLIMATES CLASS

 

T1

 

T3

 

 

T1

 

T3

 

 

 

 

 

 

 

 

 

 

 

 

 

CAPACITY

COOLING

18000 Btu/h

 

15300 Btu/h

18000 Btu/h

 

15300 Btu/h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEATING (H1)

 

 

 

-

 

 

 

 

6000 W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED VOLTAGE & FREQUENCY

 

 

230V ~ 60 Hz

 

 

 

230V ~ 60 Hz

 

RATED CURRENT

COOLING

7.0 A

 

8.0 A

 

6.5 A

 

7.6 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEATING (H1)

 

 

 

-

 

 

 

 

7.7 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED POWER

COOLING

1490 W

 

1750 W

1470 W

 

1730 W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT

HEATING (H1)

 

 

 

-

 

 

 

 

1710 W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EER/COP

COOLING

12.10 (Btu/hr)/W

 

8.75 (Btu/hr)/W

12.25 (Btu/hr)/W

8.85 (Btu/hr)/W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEATING (H1)

 

 

 

-

 

 

 

 

3.50 W/W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REFRIGERANT

TYPE

 

 

 

 

 

 

R-410A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHARGE

 

 

980 g [34.57 oz]

 

 

1380 g [48.68 oz]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ANNUAL ENERGY CONSUMPTION

 

 

4023 kWh/Year

 

 

 

3969 kWh/Year

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR

27˚C

 

-

 

29˚C

 

-

27˚C

 

20˚C

 

29˚C

 

20˚C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMPERATURE

19˚C

 

-

 

19˚C

 

-

19˚C

 

15˚C

 

19˚C

 

15˚C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR

35˚C

 

-

 

46˚C

 

-

35˚C

 

7˚C

 

46˚C

 

7˚C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24˚C

 

-

 

24˚C

 

-

24˚C

 

6˚C

 

24˚C

 

6˚C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NET WEIGHT

INDOOR

 

 

11.5 kg

 

 

 

11.5 kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR

 

 

35.2 kg

 

 

 

39.5 kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIMENSIONS OF

INDOOR

 

1065 x 298 x 243 mm

 

1065 x 298 x 243 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THE UNIT

OUTDOOR

 

880*638*310 mm

 

 

880*638*310 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COUNTRY OF ORIGIN

 

 

 

 

 

 

THAILAND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cleaning and Maintenance

English 25

Image 25
Contents Air conditioner Contents Correct disposal of batteries in this product Failing to do so may result in electric shock or fire Safety InformationThis may result in electric shock or fire For Power Supply This may result in electric shock Do not touch the circuit breakerwith wet handsThis may result in electric shock or burns This may result in children seriously injuring themselvesDo not operate the appliance with wet hands Do not clean the inside of the air conditioner by yourselfDo not drink the water from the air conditioner Operation indicator Timer indicatorIndoor Unit Overview DisplayInserting batteries Remote Control OverviewControlling temperature Remote Control OperationOperation modes Controlling air flow direction Controlling fan speedHorizontal air flow manual Cooling Operation Cool modeStep cooling function Dehumidifying Operation Dry modeHeating Operation Heat modeAuto mode Quick Smart FeaturesFan mode Comfort function Fast functionBeep sound function Quiet functionSingle user function Energy-Saving OperationTimed on/Timed off function Good’sleep function Running Auto clean Cleaning at a GlanceCleaning duration Minutes Do not clean the display by using alkaline detergentCleaning the filter Troubleshooting Replace the batteries in the remote control with new ones Problem Solution Cannot change the fanDoes not work Setting the time Indicator blinks Check whether the drains are clean. Clean them regularlyModel Technical Specifications27˚C 29˚C 20˚C General information Installation of the unitInstall the unit in a place where water can drain smoothly Power supply line, fuse, or circuit breakerInstallation manual Minimum clearances for the outdoor unit Choosing the installation locationCases Unit mm Packing and UnpackingIndoor unit Outdoor unitAccessories in the indoor unit package AccessoriesOptional accessories Drilling a hole through the wall Accessories in the outdoor unit packageTools Taping the pipes, cables, and drain hose Indoor Unit Installation Prepare the following tools Optional Extending the power cableApply heat to the contraction tube to contract it Install the drain hose Installing and connecting the drain hoseOptional Extending the drain hose Or a fireOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe When fixing the indoor unit on a wall Fixing the installation plateWhen fixing the indoor unit on a window frame Fix the installation plate without inclining to one side When fixing the indoor unit on a gypsum boardRefrigerant pipes Outdoor Unit InstallationOptional Fixing the outdoor unit to a wall with a rack Evacuating the air Leave the system in the standby modeCooling capacity and malfunction. Use a vacuum pump Refrigerant Adding refrigerantRunning the Smart Install mode Installation InspectionPerforming the gas leak tests LED Off, Blinking, OnPumping down for removing the product Performing final check and trial operationQuestions or COMMENTS?